CPC1907B Single-Pole, Normally Open Power SOIC OptoMOS Relay INTEGRATED CIRCUITS DIVISION Parameter Rating Units Description Blocking Voltage 60 V P The CPC1907B is a single-pole, normally open Load Current 6 A (1-Form-A) solid state relay that employs optically DC On-Resistance 0.06 coupled MOSFET technology to provide 5000V of rms input to output isolation. Switching of the efficient MOSFET switches is Features controlled by the photovoltaic die using the patented Handle Load Currents Up to 6A or 6A DC rms OptoMOS architecture while activation of the output 5000V Input/Output Isolation rms is controlled by a highly efficient GaAlAs infrared Power SOIC Package LED. The combination of low on-resistance and high 12.5mm External Creepage Distance load current handling capabilities makes the relay with Appropriate Layout suitable for a variety of high-performance switching High Reliability applications. No Moving Parts Low Drive Power Requirements (TTL/CMOS Compatible) Arc-Free With No Snubbing Circuits Approvals No EMI/RFI Generation UL 508 Certified Component: File E69938 CSA Industrial Control Switches Approval: Pending Applications Ordering Information Industrial Controls Security: Door Latches, Solenoids, Annunciators Part Description Motor Control CPC1907B 8-Pin Power SOIC Package (25 per tube) Heating, Ventilation, and Air Conditioning Control (HVAC) Robotics Pin Configuration Starter Ignition Circuits 8 7 6 5 Medical EquipmentPatient/Equipment Isolation Instrumentation Multiplexers Electronic Switching I/O Subsystems Home Appliances 12 3 4 DC Power Supplies N/C + LED LED N/C Aerospace Switching Characteristics of Normally Open Devices Form-A I F 90% 10% I LOAD t t on off Pb e3 DS-CPC1907B-R02 1 www.ixysic.comCPC1907B INTEGRATED CIRCUITS DIVISION Absolute Maximum Ratings 25C (Unless Otherwise Noted) Absolute Maximum Ratings are stress ratings. Stresses in Parameter Ratings Units excess of these ratings can cause permanent damage to the Blocking Voltage 60 V device. Functional operation of the device at conditions beyond Reverse Input Voltage 5 V those indicated in the operational sections of this data sheet is Input control Current 50 mA not implied. Peak (10ms) 1 A 1 Input Power Dissipation 150 mW 2 Total Power Dissipation 2400 mW Isolation Voltage, Input to Output 5000 V rms (60 Seconds Maximum) ESD, Human Body Model 8 kV Operational Temperature -40 to +85 C Storage Temperature -40 to +125 C 1 Derate linearly 3.33mW / C 2 Derate linearly 20mW / C Electrical Characteristics 25C (Unless Otherwise Noted) Parameter Conditions Symbol Min Typ Max Units Output Characteristics Load Current, Continuous free air I -- 6A , A L DC rms Peak Load Current t = 10ms I - - 20 A LPK P 1 On-Resistance I =1A R - - 0.06 L ON Off-State Leakage Current V =60V I -- 1 A L P LEAK Switching Speeds Turn-On t - 2.7 5 on I =5mA, I =100mA ms F L Turn-Off t - 0.14 1 off Output Capacitance V =50V, f=1MHz C - 340 - pF L OUT Input Characteristics 2 LED Current to Activate I =1A I - 1.5 5 mA L F LED Current to Deactivate - I 0.6 - - mA F Input Voltage Drop I =5mA V 0.9 1.2 1.4 V F F Reverse Input Current V =5V I - - 10 A R R Input/Output Characteristics Capacitance, Input/Output f=1MHz I -2 - pF I/O 1 Measurement taken within 1 second of on-time. 2 For high temperature operation (T >60C), a LED current of 10mA is recommended. A R02 2 www.ixysic.com