CPC1964BX6 Rapid Turn-On AC Power Switch INTEGRATED CIRCUITS DIVISION Description Parameter Rating Units AC Operating Voltage 20 - 240 V CPC1964BX6 is an AC Solid State Switch utilizing rms Load Current 1.5 A dual power SCR outputs. This device features Rapid rms Turn-On (non-zero-cross) control of the output SCRs, On-State Voltage Drop 1.4 V (at I = 1.5A ) P L P which makes it ideal for precisely switching AC loads Blocking Voltage 600 V P independent of the load voltage phase. The optically coupled input and output circuits Features provide 5000V of isolation and noise immunity rms Load Current up to 1.5A between the control and load circuits. As a result, the rms 600V Blocking Voltage CPC1964BX6 is well suited for industrial environments P High Surge Current: 15A where electromagnetic interference would disrupt the Rapid Turn-On (Non-Zero-Cross Turn-On) operation of plant facility communication and control 5mA Sensitivity systems. Creepage Distance: 0.220 on Output Pins 12.5mm External Creepage Distance Approvals DC Control, AC Output UL Recognized Component: File E69938 Optically Isolated CSA Certified Component: Certificate 1172007 Low EMI and RFI Generation High Noise Immunity Flammability Rating UL 94 V-0 Ordering Information Part Description CPC1964BX6 8-Pin Power SOIC (25/Tube) Applications HVAC Control (Heating, Ventilation, Air Conditioning) Lighting Pin Configuration Programmable Control AC Load AC Load Process Control 87 6 5 Power Control Panels Remote Switching Gas Pump Electronics R Contactors Large Relays Solenoids 12 3 4 Motors N/C + LED LED N/C Heaters Meters Rapid Turn-On (Non Zero-Cross) Waveforms Control AC Load Voltage Load Current Voltage Across Relay DS-CPC1964BX6-R02 1 www.ixysic.comCPC1964BX6 INTEGRATED CIRCUITS DIVISION Absolute Maximum Ratings 25C Absolute Maximum Ratings are stress ratings. Stresses in Parameter Ratings Units excess of these ratings can cause permanent damage to the Blocking Voltage (V ) 600 V DRM P device. Functional operation of the device at conditions beyond Reverse Input Voltage 5 V those indicated in the operational sections of this data sheet is Input Control Current 50 mA not implied. Peak (10ms) 1 A di/dt Critical Rate of Rise Typical values are characteristic of the device at +25C, and 20 A/s of On-State Current are the result of engineering evaluations. They are provided for 1 Input Power Dissipation 150 mW information purposes only, and are not part of the manufacturing 2 Total Power Dissipation 2400 mW testing requirements. ESD, Human Body Model 4 kV 2 2 i t Fusing Current (1/2 Sine Wave, 60Hz) 2 A s Isolation Voltage, Input to Output 5000 V rms Operational Temperature -40 to +85 C Storage Temperature -40 to +125 C 1 Derate linearly 1.33 mW / C 2 Derate linearly 20 mW / C Electrical Characteristics 25C Parameters Conditions Symbol Min Typ Max Units Output Characteristics Load Current, Continuous V =20-240V I 0.07 - 1.5 A L rms L rms Maximum Surge Current t < 16ms I -- 15 A P Off State Leakage Current V I - - 100 A DRM LEAK P On-State Voltage Drop I =1.5A - - 1.21 1.4 V L P P Off-State dV/dt - dV/dt 1000 - - V/s Switching Speeds I = 5mA, Resistive F Turn-on t - 20 500 s on V =20V, 60Hz L Turn-off t - - 0.5 cycles off Holding Current - I -44 75 mA H Latching Current - I -48 75 mA L Operating Frequency - 20 - 500 Hz Input Characteristics 1 Input Control Current to Activate 60Hz I -- 5 mA F Input Drop-out Voltage - - 0.8 - - V Input Voltage Drop I =5mA V 0.9 1.2 1.5 V F F Reverse Input Current V =5V I -- 10 A R R Common Characteristics Input to Output Capacitance V =0V, f=1MHz C -- 3 pF IO IO 1 For high-noise environments, or for high-frequency operation, use I > 10mA. F 2 R02 www.ixysic.com