CPC1966 AC Power Switch INTEGRATED CIRCUITS DIVISION Parameter Rating Units Description AC Operating Voltage 20 - 240 V rms CPC1966 is an AC Solid State Switch utilizing Load Current 3 A rms dual power SCR outputs. This device also includes On-State Voltage Drop 0.8 V (at I = 3A ) rms L rms zero-cross turn-on circuitry, and is specified with a Blocking Voltage 600 V blocking voltage of 600V . P P In addition, the tightly controlled zero-cross circuitry ensures low noise switching of AC loads by Features minimizing the generation of transients. The optically Load Current up to 3A rms coupled input and output circuits provide 3750V of rms 600V Blocking Voltage P isolation and noise immunity between the control and 5mA Sensitivity load circuits. As a result, the CPC1966 is well suited Zero-Crossing Detection for industrial environments where electromagnetic DC Control, AC Output interference would disrupt the operation of plant facility Optically Isolated communication and control systems. TTL and CMOS Compatible Low EMI and RFI Generation Approvals High Noise Immunity UL Recognized Component: File E69938 Machine Insertable, Wave Solderable CSA Certified Component: File 043639 Ordering Information Applications Programmable Control Part Description Process Control CPC1966Y 4-Pin (8-Pin Body) SIP (25/Tube) Power Control Panels Remote Switching Gas Pump Electronics Pin Configuration Contactors Large Relays Solenoids Motors ZC Heaters 1 2 3 4 LED + LED AC Load AC Load DS-CPC1966-R04 1 www.ixysic.comCPC1966 INTEGRATED CIRCUITS DIVISION Absolute Maximum Ratings 25C Absolute Maximum Ratings are stress ratings. Stresses in Parameter Ratings Units excess of these ratings can cause permanent damage to Blocking Voltage (V ) 600 V DRM P the device. Functional operation of the device at conditions Reverse Input Voltage 5 V beyond those indicated in the operational sections of this Input Control Current 50 mA data sheet is not implied. Peak (10ms) 1 A 1 Input Power Dissipation 150 mW 2 Total Power Dissipation 2400 mW Isolation Voltage, Input to Output 3750 V rms Operational Temperature -40 to +85 C Storage Temperature -40 to +125 C 1 Derate linearly 1.33 mW / C 2 Derate linearly 20 mW / C Electrical Characteristics 25C Parameters Conditions Symbol Min Typ Max Units Output Characteristics Load Current, Continuous V =120-240V I 0.1 - 3 A L rms L rms Maximum Surge Current t < 16ms I -- 30 A P Off State Leakage Current V I - - 100 A DRM LEAK P 1 On-State Voltage Drop I =2A - - 0.88 1.1 V L P P Off-State dV/dt - dV/dt 500 - - V/s Switching Speeds Turn-on t - - 0.5 cycles I = 5 mA on F Turn-off t - - 0.5 cycles off 2 Zero-Cross Turn-On Voltage 1st half-cycle - - 5 20 V Subsequent half-cycle - - - 5 V Holding Current - I -44 50 mA H Latching Current - I -48 75 mA L Operating Frequency - 20 - 500 Hz Load Power Factor for 3 Guaranteed Turn-On 60Hz PF 0.25 - - - Input Characteristics 4 Input Control Current to Activate 60Hz I -- 5 mA F Input Drop-out Voltage - - 0.8 - - V Input Voltage Drop I =5mA V 0.9 1.2 1.4 V F F Reverse Input Current V =5V I -- 10 A R R Common Characteristics Input to Output Capacitance - C -- 3 pF I/O 1 Tested at a peak value equivalent. 2 Zero Cross 1st half-cycle <100Hz. 3 Snubber circuits may be required at low power factors. 4 For high-noise environments, or for high-frequency operation, use I > 10mA. F R04 2 www.ixysic.com