CPC2125N 400V, 100mA Dual Single-Pole Normally Closed Relay INTEGRATED CIRCUITS DIVISION Parameter Rating Units Description Blocking Voltage 400 V The CPC2125N is a miniature device with two P independent normally-closed (1-Form-B) solid state Load Current 100 mA / mA rms DC relays in an 8-pin SOIC package that employs On-Resistance (max) 35 optically coupled MOSFET technology to provide LED Forward Current (to Activate) 2 mA 1500V of input to output isolation. rms Optically coupled outputs, using the patented Features OptoMOS architecture, are controlled by a highly 1500V Input/Output Isolation rms efficient infrared LED. No EMI/RFI Generation Immune to Radiated EM Fields Constructed using IXYS Integrated Circuits state Tape & Reel Version Available of the art double-molded, vertical construction Small 8-Pin SOIC Package packaging, this device is one of the worlds smallest Flammability Rating UL 94 V-0 relays. It offers substantial board space savings over the competitors larger 8-pin SOIC relay. Applications Approvals Telecommunications Telecom Switching UL Recognized Component: File E76270 Tip/Ring Circuits TUV EN 62368-1: Certificate B 082667 0008 Modem Switching (Laptop, Notebook, Pocket Size) Hook Switch Ordering Information Dial Pulsing Ground Start Part Description Ringing Injection CPC2125N 8-Pin SOIC (50/tube) Security CPC2125NTR 8-Pin SOIC (2000/reel) Passive Infrared Detectors (PIR) Data Signaling Sensor Circuitry Pin Configuration Instrumentation 1 8 Multiplexers + Control Load Data Acquisition 2 7 Electronic Switching Control Load I/O Subsystems Medical EquipmentPatient/Equipment Isolation 3 6 + Control Load Industrial Controls 4 5 Control Load Switching Characteristics of Normally-Closed (Form-B) Devices Form-B I F I LOAD 90% 10% t t off on DS-CPC2125N-R06 1 www.ixysic.comCPC2125N INTEGRATED CIRCUITS DIVISION Absolute Maximum Ratings 25C Absolute Maximum Ratings are stress ratings. Stresses in Parameter Ratings Units excess of these ratings can cause permanent damage to the Blocking Voltage 400 V P device. Functional operation of the device at conditions beyond Reverse Input Voltage 5 V those indicated in the operational sections of this data sheet is LED Forward Current 50 mA not implied. Peak (10ms) 1A Input Power Dissipation 70 mW Typical values are characteristic of the device at +25C, and 1 Total Power Dissipation 600 mW are the result of engineering evaluations. They are provided for Isolation Voltage, Input to Output 1500 V information purposes only, and are not part of the manufacturing rms (60 Seconds) testing requirements. ESD Rating, Human Body Model 8 kV Operational Temperature, Ambient -40 to +85 C Storage Temperature -40 to +125 C 1 Derate linearly 5mW / C Electrical Characteristics 25C Parameter Conditions Symbol Min Typ Max Units Output Characteristics Blocking Voltage I =1AV 400 - - V L DRM Load Current 1 Continuous I =0mA I - - 100 mA / mA F L rms DC Peak t =10ms I - - 350 mA LPK P 2 On-Resistance I =100mA R -26 35 L ON Switching Speeds Turn-On t - 0.31 2 on I =5mA, V =10V ms F L Turn-Off t - 0.30 2 off Off-State Leakage Current V =400V, I =2mA I -- 5 A L F LEAK Output Capacitance I =2mA, V = 50V, f=1MHz C -6 - pF F L OUT Input Characteristics LED Forward Current 3 To Activate I =100mA -- 2 L I mA F To Deactivate - 0.1 - - Input Voltage Drop I =5mA V 0.9 1.36 1.5 V F F Reverse Input Current V =5V I - - 10 A R R Common Characteristics Capacitance, Input to Output V =0V, f=1MHz C -1 - pF IO IO 1 o o Load current derates linearly from 100mA 25 C to 60mA 85 C, and must be derated if both poles are operating simultaneously. 2 Measurement taken within 1 second of on-time. 3 For applications requiring high temperature operation (greater than 60C) a minimum LED forward current of 4mA is recommended. 2 R06 www.ixysic.com