CPC2907B Dual 60V Single-Pole Normally Open OptoMOS Relay INTEGRATED CIRCUITS DIVISION Parameter Ratings Units Description Blocking Voltage 60 V CPC2907B is a dual, normally open (1-Form-A) Solid P State Relay that comprises two independent, optically Load Current 2 A / A rms DC coupled MOSFET switches. The combination of highly On-Resistance (max) 0.15 efficient LEDs and photovoltaic die makes possible an input to output isolation of 4000V . rms Features The optically coupled output driver, which uses the Dual Relays patented OptoMOS architecture, is controlled by a Low On-resistance: 150m Max highly efficient infrared LED. 2 Amp Load Current Single-Pole Operation 4000V Input/Output Isolation Dual OptoMOS relays provide a more compact design rms Low Drive Power Requirements solution than discrete single-pole relays in a variety of High Reliability applications, saving board space by incorporating both Arc-Free With No Snubbing Circuits switches in a single 8-pin package. No EMI/RFI Generation 8-Pin SOIC Surface Mount Package Flammability Rating UL 94 V-0 Approvals UL 508 Certified Component: File E69938 CSA Certified Component: Certificate 1175739 Applications EN/IEC 60950-1 Certified Component: Security Certificate available on our website Instrumentation Multiplexers Ordering Information Data Acquisition Part Description Electronic Switching I/O Subsystems CPC2907B 8-Pin Power SOIC (25/Tube) Medical Equipment-Patient/Equipment Isolation Industrial Controls Pin Configuration 8 1 Load - Switch 1 + Control - Switch 1 2 Control - Switch 1 7 Load - Switch 1 6 3 Load - Switch 2 + Control - Switch 2 4 Control - Switch 2 5 Load - Switch 2 Switching Characteristics of Normally Open (Form A) Devices Form-A I F 90% 10% I LOAD t t on off DS-CPC2907B-R03 1 www.ixysic.comCPC2907B INTEGRATED CIRCUITS DIVISION Absolute Maximum Ratings 25C Absolute Maximum Ratings are stress ratings. Stresses in Parameter Ratings Units excess of these ratings can cause permanent damage to Blocking Voltage 60 V P the device. Functional operation of the device at conditions Reverse Input Voltage 5 V beyond those indicated in the operational sections of this Input Control Current 50 mA data sheet is not implied. Peak (10ms) 1 A 1 Typical values are characteristic of the device at +25C, Input Power Dissipation 150 mW and are the result of engineering evaluations. They are Output Power Dissipation provided for information purposes only, and are not part of 2 Single Pole 1125 the manufacturing testing requirements. mW 3 Both Poles 1700 Isolation Voltage, Input to Output 4000 V rms Operational Temperature (T ) -40 to +85 C A Storage Temperature -40 to +125 C 1 Derate linearly 1.33 mW / C 2 Derate linearly 11.4 mW / C 3 Derate linearly 17.1 mW / C Electrical Characteristics 25C Parameter Conditions Symbol Min Typ Max Units Output Characteristics Load Current 1 Continuous, Single-pole -I -- 2 A / A L rms DC Peak t =10ms I - - 10 A LPK P 2 On-Resistance I =5mA, I =1A R - 0.10 0.15 F L ON Off-State Leakage Current V =60V I -- 1 A L P LEAK Switching Speeds Turn-On t - 0.62 2.5 on I =5mA, V =10V ms F L Turn-Off t - 0.09 0.25 off Output Capacitance I =0mA, V =50V, f=1MHz C -60 - pF F L OUT Input Characteristics 3 Input Control Current to Activate I =1A I - 0.78 5 mA L F Input Control Current to Deactivate - - 0.4 0.78 - mA Input Voltage Drop I =5mA V 0.9 1.2 1.5 V F F Reverse Input Current V =5V I -- 10 A R R Common Characteristics Capacitance, Input to Output V =0V, f=1MHz C -3 - pF IO IO 1 If both poles operate at the same time, the load current must be derated in order not to exceed the package power dissipation value. Total Load Current See Total Load Current chart on this page. 2.5 2 Measurement taken within one (1) second of on-time. 3 For applications requiring operation at temperatures greater than 60C, 25C a minimum LED drive current of 10mA is recommended. 2.0 55C 1.5 85C 1.0 0.5 0.0 0.0 0.5 1.0 1.5 2.0 2.5 Pole 1 Current (A) 2 R03 www.ixysic.com Pole 2 Current (A)