CPC44055ST AC Power Switch INTEGRATED CIRCUITS DIVISION Characteristics Description CPC44055ST is a voltage-controlled AC Solid State Parameter Rating Units Switch utilizing dual power SCR outputs. This device V (V ) AC Operating Voltage 20-280 AC rms also includes zero-cross turn-on circuitry and is specified with an 800V blocking voltage. Input Voltage Range 9-16 V P Load Current Tightly controlled zero-cross circuitry ensures low With 5C/W Heat Sink 20 noise switching of AC loads by minimizing the A rms No Heat Sink 5 generation of transients. The optically coupled input V (at I =2A ) and output circuits provide exceptional noise immunity On-State Voltage Drop 1.1 P L P and 2500V of isolation. As a result, the rms V Blocking Voltage 800 P CPC44055ST is well suited for industrial environments Thermal Resistance, where electromagnetic interference would disrupt the 0.35 C/W Junction-to-Case, JC operation of communications and control systems. Features The unique SuperSIP package pioneered by IXYS Integrated Circuits Division allows Solid State Relays Load Current up to 20A with 5C/W Heat Sink rms to achieve the highest load current currently available 800V Blocking Voltage P in any similar-sized package. This package features a Creepage Pin 1 to Pin 2 of 0.225 inch (5.715 mm) unique process in which the silicon chips are soft Zero-Cross Switching soldered onto the Direct Copper Bond (DCB) 2500V Isolation, Input to Output rms substrate instead of the traditional copper leadframe. Creepage Pin 2 to Pin 3 of 0.375 inch (9.525 mm) The DCB ceramic, the same substrate used in high DC Voltage Control, AC Output power modules, not only provides 2500V isolation rms Optically Isolated but also very low junction-to-case thermal resistance Low EMI and RFI Generation (0.35C/W). High Noise Immunity Machine Insertable, Wave Solderable Ordering Information Applications Part Description Lighting Tungsten Load: 4.75A (Free Air), 15A (Heat Sink) CPC44055ST SuperSIP Package (13 per tube) Electrical Ballast: 5A (Free Air), 15A (Heat Sink) Programmable Controls Pin Configuration & Waveforms Process Controls Power Control Panels Remote Switching ZC Gas Pump Electronics Contactors Large Relays 1 2 3 4 AC Load +V V Solenoids Motors: 1/3HP (Free Air), 1/2HP (Heat Sink) Control Heaters Approvals AC Line UL 508 Recognized Component: File E69938 See UL Approved Ratings on page 4. Load Current Voltage Across Relay DS-CPC44055ST-R02 www.ixysic.com 1CPC44055ST INTEGRATED CIRCUITS DIVISION 1 Specifications 1.1 Absolute Maximum Ratings 25C Symbol Min Max Units Absolute maximum ratings are stress ratings. Stresses in Blocking Voltage - 800 excess of these ratings can cause permanent damage to V P the device. Functional operation of the device at conditions Reverse Input Voltage - 5 V beyond those indicated in the operational sections of this Input Control Voltage - 17 V 1 data sheet is not implied. -225 mW Input Power Dissipation 2 -4.4 Total Power Dissipation W 2 Typical values are characteristic of the device at +25C, I t for Fusing 2 -200 A s and are the result of engineering evaluations. They are (1/2 Sine Wave, 60Hz) provided for information purposes only, and are not part of Isolation Voltage, Input to Output 60 - 2500 V rms the manufacturing testing requirements. Seconds ESD, Human Body Model - 4 kV Operational Temperature - 40 +85 C Storage Temperature - 40 +125 C 1 Derate linearly 1.33mW / C. 2 Free air, no heat sink. 1.2 Recommended Operating Conditions Parameter Conditions Symbol Min. Typ. Max. Units 1 T =-40C to 85C V 9- 16 V Input Control Voltage A IN 1 For high-noise environments, or high-frequency operation (>60Hz), or for applications with a high inductive load, use V >10V. IN 1.3 Electrical Characteristics 25C Parameter Conditions Symbol Minimum Typical Maximum Units Output Characteristics Load Current No Heat Sink, V =20-280V Continuous L rms 0.1 - 5 I A L rms T =25C Continuous C 0.1 - 40 Maximum Surge Current 1/2 Sine Wave, 60Hz I - - 150 A P V =800V Off-State Leakage Current I A L - - 100 LEAK P 1 I =2A - - 0.85 1.1 V On-State Voltage Drop L P P Off-State dV/dt V =0V dV/dt 1000 -- V/s IN Switching Speeds Turn-On t -- 0.5 on V =10V cycles IN Turn-Off t -- 0.5 off st Zero-Cross Turn-On Voltage - 1 half-cycle -6.8 20 V subsequent half-cycle - -- 5 Holding Current - I -- 50 mA H Latching Current - I -- 75 mA L 2 - Operating Frequency - 20 - 500 Hz 3 f=60Hz Load Power Factor for Guaranteed Turn-On PF 0.25 -- - Input Characteristics Input Resistor - R 0.911.1 k IN I =1A Resistive, f=60Hz V Input Control Voltage to Activate -- 5 V L IN Input Control Voltage to Deactivate - -0.8 - - V V =10V Input Current I 7.8 8.8 10.1 mA IN IN V =5V Reverse Input Current I R -- 10 A R Input/Output Characteristics V =0V, f=1MHz Capacitance, Input-to-Output C -- 3 pF IO IO 1 Tested at a peak value equivalent. 2 Zero-cross first half-cycle < 100Hz. 3 Snubber circuits may be required at low power factors. R02 www.ixysic.com 2