LBA120L Dual Single-Pole OptoMOS Relay INTEGRATED CIRCUITS DIVISION Description Parameter Ratings Units LBA120L comprises two independent 250V, 170mA, Blocking Voltage 250 V P 20 solid state relays: one single-pole, normally open Load Current 170 mA / mA rms DC (1-Form-A) current limited relay and one single-pole, On-Resistance (max) 20 normally closed (1-Form-B) relay. LBA120L is designed to provide an ideal solution Features where a complementary Form-A/Form-B relay pair is Current Limited required. 3750V Input/Output Isolation rms Low Drive Power Requirements (TTL/CMOS Compatible) Approvals High Reliability UL Recognized Component: File E76270 Arc-Free With No Snubbing Circuits CSA Certified Component: Certificate 1175739 FCC Compatible EN/IEC 60950-1 Certified Component VDE Compatible TUV Certificate B 09 07 49410 004 No EMI/RFI Generation Small 8-Pin Package Machine Insertable, Wave Solderable Surface Mount, Tape & Reel Version Available Ordering Information Part Description Applications LBA120L 8-Pin DIP (50/Tube) Telecommunications LBA120LS 8-Pin Surface Mount (50/Tube) Telecom Switching LBA120LSTR 8-Pin Surface Mount (1,000/Reel) Tip/Ring Circuits Modem Switching (Laptop, Notebook, Pocket Size) Hook Switch Dial Pulsing Pin Configuration Ground Start Ringing Injection AC/DC Configuration 1 8 Instrumentation + Control - Normally Closed Normally Closed Pole Multiplexers 2 7 Control - Normally Closed Data Acquisition 3 6 + Control - Normally Open Electronic Switching Normally Open Pole 4 5 I/O Subsystems Control - Normally Open Meters (Watt-Hour, Water, Gas) Medical Equipment-Patient/Equipment Isolation Security Aerospace Industrial Controls Switching Characteristics of Switching Characteristics of Normally Open Devices Normally Closed Devices Form-A Form-B I I F F I LOAD 90% 90% 10% 10% I LOAD t t t t off on on off Pb e3 DS-LBA120L-R05 1 www.ixysic.comLBA120L INTEGRATED CIRCUITS DIVISION Absolute Maximum Ratings 25C Absolute Maximum Ratings are stress ratings. Stresses in Parameter Ratings Units excess of these ratings can cause permanent damage to Blocking Voltage 250 V P the device. Functional operation of the device at conditions Reverse Input Voltage 5 V beyond those indicated in the operational sections of this Input Control Current 50 mA data sheet is not implied. Peak (10ms) 1 A 1 Input Power Dissipation 150 mW 2 Total Power Dissipation 800 mW Isolation Voltage, Input to Output 3750 V rms Operational Temperature -40 to +85 C Storage Temperature -40 to +125 C 1 Derate linearly 1.33 mW / C 2 Derate linearly 6.67 mW / C Electrical Characteristics 25C Parameter Conditions Symbol Min Typ Max Units Output Characteristics Load Current 1 Continuous -I - - 150 mA / mA L rms DC Load Current Limiting (1-Form-A Only) - I 190 235 280 mA CL On-Resistance I =170mA R -21 25 L ON Off-State Leakage Current V =250V I -- 1 A L P LEAK Switching Speeds Turn-On t -- 5 on I =5mA, V =10V ms F L Turn-Off t -- 5 off Output Capacitance V =50V, f=1MHz C -50 - pF L OUT Input Characteristics Input Control Current to Activate I =120mA I -- 5 mA L F Input Control Current to Deactivate - I 0.4 0.7 - mA F Input Voltage Drop I =5mA V 0.9 1.2 1.4 V F F Reverse Input Current V =5V I -- 10 A R R Common Characteristics Input to Output Capacitance - C -3 - pF I/O 1 If both poles operate the load current must be derated so as not to exceed the package power dissipation value. R05 2 www.ixysic.com