LBA120 Dual Single-Pole OptoMOS Relay INTEGRATED CIRCUITS DIVISION Parameter Ratings Units Description Blocking Voltage 250 V LBA120 comprises two independent 250V, 170mA, P 20 solid state relays: one single-pole, normally Load Current 170 mA / mA rms DC open (1-Form-A) relay and one single-pole, normally On-Resistance (max) 20 closed (1-Form-B) relay. Featuring low on-resistance combined with enhanced Features peak load current handling capabilities, LBA120 3750V Input/Output Isolation rms is designed to provide an ideal solution where a Low Drive Power Requirements (TTL/CMOS complementary Form-A/Form-B relay pair is required. Compatible) High Reliability Approvals Arc-Free With No Snubbing Circuits FCC Compatible UL Recognized Component: File E76270 VDE Compatible CSA Certified Component: Certificate 1175739 No EMI/RFI Generation EN/IEC 60950-1 Certified Component Small 8-Pin Package TUV Certificate B 09 07 49410 004 Machine Insertable, Wave Solderable Surface Mount, Tape & Reel Versions Available Ordering Information Part Description Applications LBA120 8-Pin DIP (50/Tube) Telecommunications LBA120S 8-Pin Surface Mount (50/Tube) Telecom Switching LBA120STR 8-Pin Surface Mount (1,000/Reel) Tip/Ring Circuits LBA120P 8-Pin Flat Pack (50/Tube) Modem Switching (Laptop, Notebook, Pocket Size) LBA120PTR 8-Pin Flat Pack (1,000/Reel) Hook Switch Dial Pulsing Ground Start Ringing Injection Pin Configuration Instrumentation Multiplexers AC/DC Configuration Data Acquisition 1 8 + Control - Normally Closed Electronic Switching Normally Closed Pole 2 7 Control - Normally Closed I/O Subsystems 3 6 Meters (Watt-Hour, Water, Gas) + Control - Normally Open Normally Open Pole Medical Equipment-Patient/Equipment Isolation 4 5 Control - Normally Open Security Aerospace Industrial Controls Switching Characteristics of Switching Characteristics of Normally Open Devices Normally Closed Devices Form-A Form-B I I F F I LOAD 90% 90% 10% 10% I LOAD t t t t off on on off Pb e 3 DS-LBA120-R07 1 www.ixysic.comLBA120 INTEGRATED CIRCUITS DIVISION Absolute Maximum Ratings 25C Absolute Maximum Ratings are stress ratings. Stresses in Parameter Ratings Units excess of these ratings can cause permanent damage to Blocking Voltage 250 V P the device. Functional operation of the device at conditions Reverse Input Voltage 5 V beyond those indicated in the operational sections of this Input Control Current 50 mA data sheet is not implied. Peak (10ms) 1 A 1 Input Power Dissipation 150 mW 2 Total Power Dissipation 800 mW Isolation Voltage, Input to Output 3750 V rms Operational Temperature -40 to +85 C Storage Temperature -40 to +125 C 1 Derate linearly 1.33 mW / C 2 Derate linearly 6.67 mW / C Electrical Characteristics 25C Parameter Conditions Symbol Min Typ Max Units Output Characteristics Load Current 1 Continuous -I - - 170 mA / mA L rms DC Peak t = 10ms I - - 400 mA LPK P On-Resistance I =170mA R -16 20 L ON Off-State Leakage Current V =250V I -- 1 A L P LEAK Switching Speeds Turn-On t -- 5 on I =5mA, V =10V ms F L Turn-Off t -- 5 off Output Capacitance V =50V, f=1MHz C -50 - pF L OUT Input Characteristics Input Control Current to Activate I =120mA I -- 5 mA L F Input Control Current to Deactivate - I 0.4 0.7 - mA F Input Voltage Drop I =5mA V 0.9 1.2 1.4 V F F Reverse Input Current V =5V I -- 10 A R R Common Characteristics Input to Output Capacitance - C -3 - pF I/O 1 If both poles operate, then the load current must be derated so as not to exceed the package power dissipation value. R07 2 www.ixysic.com