LBA127 Dual Single-Pole, Combination OptoMOS Relay INTEGRATED CIRCUITS DIVISION Parameter Ratings Units Description Blocking Voltage 250 V LBA127 is a combination device comprising one P Load Current 200 mA / mA normally open (1-Form-A) and one normally rms DC closed (1-Form-B) solid state relay. Both relays are On-Resistance (max) 10 independent, 250V, 200mA, 10 devices designed to provide an ideal solution where a complementary relay pair (1-Form-A / 1-Form-B) is required. Features 3750V Input/Output Isolation rms Low Drive Power Requirements Approvals (TTL/CMOS Compatible) High Reliability UL Recognized Component: File E76270 Arc-Free With No Snubbing Circuits CSA Certified Component: Certificate 1175739 FCC Compatible EN/IEC 60950-1 Certified Component: VDE Compatible TUV Certificate B 09 07 49410 004 No EMI/RFI Generation Small 8-Pin Package Ordering Information Machine Insertable, Wave Solderable Surface Mount, Tape & Reel Version Available Part Description LBA127 8-Pin DIP (50/Tube) LBA127P 8-Pin Flatpack (50/Tube) Applications LBA127PTR 8-Pin Flatpack (1000/Reel) Telecommunications LBA127S 8-Pin Surface Mount (50/Tube) Telecom Switching LBA127STR 8-Pin Surface Mount (1000/Reel) Tip/Ring Circuits Modem Switching (Laptop, Notebook, Pocket Size) Hook Switch Pin Configuration Dial Pulsing Ground Start 1 8 + Control - Normally Closed Ringing Injection Normally Closed Pole 2 7 Instrumentation Control - Normally Closed 3 6 Multiplexers + Control - Normally Open Normally Open Pole Data Acquisition 4 5 Control - Normally Open Electronic Switching I/O Subsystems Meters (Watt-Hour, Water, Gas) Medical Equipment-Patient/Equipment Isolation Switching Characteristics of Switching Characteristics of Normally Open Normally Closed Security (Form A) Devices (Form B) Devices Aerospace Industrial Controls Form-A Form-B I I F F I LOAD 90% 90% 10% 10% I LOAD t t t t off on on off Pb e3 DS-LBA127-R12 1 www.ixysic.comLBA127 INTEGRATED CIRCUITS DIVISION Absolute Maximum Ratings 25C Absolute Maximum Ratings are stress ratings. Stresses in Parameter Ratings Units excess of these ratings can cause permanent damage to Blocking Voltage 250 V P the device. Functional operation of the device at conditions Reverse Input Voltage 5 V beyond those indicated in the operational sections of this Input Control Current 50 mA data sheet is not implied. Peak (10ms) 1 A 1 Input Power Dissipation 150 mW 2 Total Power Dissipation 800 mW Isolation Voltage, Input to Output 3750 V rms Operational Temperature -40 to +85 C Storage Temperature -40 to +125 C 1 Derate linearly 1.33 mW / C 2 Derate linearly 6.67 mW / C Electrical Characteristics 25C Parameter Conditions Symbol Min Typ Max Units Output Characteristics Load Current 1 Continuous -I - - 200 mA / mA L rms DC Peak t = 10ms I - - 400 mA LPK P 2 On-Resistance I =200mA R - 6.8 10 L ON Off-State Leakage Current V =250V I -- 1 A L P LEAK Switching Speeds Turn-On t -- 5 on I =5mA, V =10V ms F L Turn-Off t -- 5 off Output Capacitance V =50V, f=1MHz C - 110 - pF L OUT Input Characteristics Input Control Current to Activate I =200mA I -- 5 mA L F Input Control Current to Deactivate - I 0.4 0.7 - mA F Input Voltage Drop I =5mA V 0.9 1.2 1.4 V F F Reverse Input Current V =5V I -- 10 A R R Common Characteristics Input to Output Capacitance - C -3 - pF I/O 1 If both poles operate simultaneously, then the load current must be derated so as not to exceed the package power dissipation value. 2 Measurement taken within 1 second of on-time. R12 2 www.ixysic.com