LBB127 250V, 200mA Dual Single-Pole Normally Closed Relays INTEGRATED CIRCUITS DIVISION Parameter Ratings Units Description Blocking Voltage 250 V LBB127 is a 250V, 200mA, 10 dual normally closed P (1-Form-B) Solid State Relay that comprises two Load Current 200 mA / mA rms DC independently controlled, optically coupled MOSFET On-Resistance (max) 10 switches. It is provided in an 8-pin package, and employs optically coupled MOSFET technology to provide 3750V of input to output isolation. rms Features 3750V Input/Output Isolation rms Its optically coupled outputs, which use the patented Low Drive Power Requirements OptoMOS architecture, are controlled by a highly Greater Reliability than Electromagnetic Relays efficient infrared LED. No EMI/RFI Generation Small 8-Pin Package This dual single-pole OptoMOS relay provides a more Flammability Rating UL 94 V-0 compact design solution than discrete single-pole Surface Mount Tape & Reel Versions Available relays in a variety of applications, and saves board space by incorporating both switches in a single 8-pin package. Applications Telecommunications Approvals Instrumentation UL Recognized Component: File E76270 Multiplexers CSA Certified Component: Certificate 1175739 Data Acquisition TUV EN 62368-1: Certificate B 082667 0008 Electronic Switching I/O Subsystems Meters (Watt-Hour, Water, Gas) Ordering Information Medical Equipment-Patient/Equipment Isolation Part Description Security LBB127 8-Pin DIP (50/Tube) Industrial Controls LBB127S 8-Pin Surface Mount (50/Tube) LBB127STR 8-Pin Surface Mount (1,000/Reel) LBB127P 8-Pin SOIC (Flatpack) (50/Tube) LBB127PTR 8-Pin SOIC (Flatpack) (1,000/Reel) Pin Configuration 1 8 + Control - Switch 1 Load - Switch 1 2 7 Control - Switch 1 Load - Switch 1 3 6 + Control - Switch 2 Load - Switch 2 4 5 Control - Switch 2 Load - Switch 2 Switching Characteristics of Normally Closed (Form B) Devices Form-B I F I LOAD 90% 10% t t off on DS-LBB127-R08 1 www.ixysic.comLBB127 INTEGRATED CIRCUITS DIVISION Absolute Maximum Ratings 25C Absolute Maximum Ratings are stress ratings. Stresses in Parameter Ratings Units excess of these ratings can cause permanent damage to Blocking Voltage 250 V P the device. Functional operation of the device at conditions Reverse Input Voltage 5 V beyond those indicated in the operational sections of this Input Control Current 50 mA data sheet is not implied. Peak (10ms) 1 A Typical values are characteristic of the device at +25C, 1 Input Power Dissipation 150 mW and are the result of engineering evaluations. They are 2 Total Power Dissipation 800 mW provided for information purposes only, and are not part of Isolation Voltage, Input to Output 3750 V the manufacturing testing requirements. rms Operational Temperature, Ambient -40 to +85 C Storage Temperature -40 to +125 C 1 Derate linearly 1.33 mW / C 2 Derate output power linearly 6.67 mW / C Electrical Characteristics 25C Parameter Conditions Symbol Min Typ Max Units Output Characteristics Blocking Voltage I =5mA, I =1AV 250 - - V F L DRM P Load Current, AC/DC 1 Continuous -I - - 200 mA / mA L rms DC Peak t =10ms I - - 400 mA LPK P On-Resistance I =200mA R -8 10 L ON Off-State Leakage Current V =250V I -- 1 A L P LEAK Switching Speeds Turn-On t -- 5 on I =5mA, V =10V ms F L Turn-Off t -- 5 off Output Capacitance I =5mA, V =50V, f=1MHz C -50 - pF F L OUT Input Characteristics Input Control Current to Activate I =200mA I -- 5 mA L F Input Control Current to Deactivate - I 0.4 0.7 - mA F Input Voltage Drop I =5mA V 0.9 1.36 1.5 V F F Reverse Input Current V =5V I -- 10 A R R Common Characteristics Input to Output Capacitance V =0V, f=1MHz C -3 - pF IO IO 1 If both poles operate, then the load current must be derated so as not to exceed the package power dissipation value. 2 R08 www.ixysic.com