LCA701 100V, 1.5A Single-Pole Normally Open Relay INTEGRATED CIRCUITS DIVISION Description Parameter Rating Units IXYS Integrated Circuits LCA701 is a 100V, 1.5A, Blocking Voltage 100 V P 0.3, normally open (1-Form-A) solid state relay Load Current 1.5 A / A rms DC that uses optically coupled MOSFET technology to On-Resistance (max) 0.3 provide 3750V of input-to-output isolation. Input Control Current 2 mA rms Its optically coupled outputs, which use the patented OptoMOS architecture, are controlled by a highly efficient infrared LED. Features 100V Blocking Voltage P LCA701 is designed to replace electromechanical Operational Temperature Range: -40C to +85C relays, and offers fast, reliable, bounce-free operation, 3750V Input/Output Isolation rms as well as the superior reliability associated with solid Low Drive Power Requirements state devices. No EMI/RFI Generation Small 6-Pin Package Flammability Rating UL 94 V-0 Approvals Surface Mount and Tape & Reel Version Available UL Recognized Component: File E76270 TUV EN 62368-1: Certificate B 082667 0008 Applications Ordering Information Instrumentation Part Description Multiplexers LCA701 6 Pin DIP (50/Tube) Data Acquisition LCA701S 6 Pin Surface Mount (50/Tube) Electronic Switching LCA701STR 6 Pin Surface Mount (1000/Reel) I/O Subsystems Meters (Watt-Hour, Water, Gas) Medical EquipmentPatient/Equipment Isolation Pin Configuration Security Industrial Controls AC/DC Configuration 1 6 + Control Load 2 5 Control Do Not Use 3 4 Do Not Use Load DC-Only Configuration 1 6 + Control + Load 2 5 Control Load 3 4 Do Not Use Switching Characteristics of Normally Open (Form A) Devices Form-A I F 90% 10% I LOAD t t on off DS-LCA701-R05 1 www.ixysic.comINTEGRATED CIRCUITS DIVISION LCA701 Absolute Maximum Ratings 25C Absolute Maximum Ratings are stress ratings. Stresses in Parameter Ratings Units excess of these ratings can cause permanent damage to Blocking Voltage 100 V P the device. Functional operation of the device at conditions Reverse Input Voltage 5 V beyond those indicated in the operational sections of this Input Control Current 50 mA data sheet is not implied. Peak (10ms) 1 A 1 Input Power Dissipation 150 mW Typical values are characteristic of the device at +25C, 2 and are the result of engineering evaluations. They are Total Power Dissipation 800 mW provided for information purposes only, and are not part of ESD Rating, Human Body Model 8 kV the manufacturing testing requirements. Isolation Voltage, Input to Output (60 Seconds) 3750 V rms Operational Temperature, Ambient -40 to +85 C Storage Temperature -40 to +125 C 1 Derate linearly 1.33 mW / C 2 Derate output power linearly 6.67 mW / C Electrical Characteristics 25C Parameter Conditions Symbol Min Typ Max Units Output Characteristics Blocking Voltage I =1AV 100 - - V L DRM P Load Current 1 Continuous, AC/DC Configuration 1.5 A / A rms DC -I -- L Continuous, DC-Only Configuration 2.5 A DC Peak t=10ms I -- 5 A LPK P 2 On-Resistance AC/DC Configuration I =5mA, I =1.5A - 0.2 0.3 F L R ON DC-Only Configuration I =5mA, I =2.5A - 0.06 0.09 F L Off-State Leakage Current V =100V I -- 1 A L P LEAK Switching Speeds Turn-On t - 1.95 4 on I =5mA, V =10V ms F L Turn-Off t - 0.45 1 off Output Capacitance I =0mA, V =0V, f=1MHz - - 200 - pF F L Input Characteristics 3 Input Control Current to Activate I =1A I - 0.14 2 mA L F Input Control Current to Deactivate - I 0.1 - - mA F Input Voltage Drop I =5mA V 0.9 1.36 1.5 V F F Reverse Input Current V =5V I -- 10 A R R Common Characteristics Input to Output Capacitance V =0V, f=1MHz C -3 - pF IO IO 1 Load current derates linearly from 1.5A 25C to 0.75A 85C. 2 Measurement taken within one second of turn-on time. 3 For applications requiring high temperature operation (T > 60C) a minimum LED drive current of 5mA is recommended. A 2 R05 www.ixysic.com