LCA717 Single-Pole, Normally Open OptoMOS Relay INTEGRATED CIRCUITS DIVISION Description Parameter Ratings Units Blocking Voltage 30 V The LCA717 is a 30V single-pole, normally open P Load Current 2 A / A (1-Form-A) Solid State Relay. It uses optically rms DC On-Resistance (max) 0.15 coupled MOSFET technology to provide 3750V rms of input to output isolation, and features an ultra-low on-resistance for high-current operation. Features Very Low Maximum On-Resistance: 0.15 Its optically coupled outputs, which use the patented High Load Current: 2A OptoMOS architecture, are controlled by a highly 3750V Input/Output Isolation rms efficient GaAIAs infrared LED. Low Drive Power Requirements (TTL/CMOS Compatible) Offering the superior reliability associated with No Moving Parts semiconductor devices, the LCA717 can be used to High Reliability replace mechanical relays. Because it has no moving Arc-Free With No Snubbing Circuits parts, it can offer faster, bounce-free switching in a No EMI/RFI Generation more compact surface mount or thru-hole package. Small 6-Pin DIP Package Machine Insertable, Wave Solderable Approvals Surface Mount, Tape & Reel Version Available UL Recognized Component: File E76270 CSA Certified Component: Certificate 1175739 Applications EN/IEC 60950-1 Certified Component: Sensor Circuitry TUV Certificate B 09 07 49410 006 Instrumentation Multiplexers Ordering Information Data Acquisition Part Description Electronic Switching LCA717 6-Pin DIP (50/Tube) I/O Subsystems LCA717S 6-Pin Surface Mount (50/Tube) Meters (Watt-Hour, Water, Gas) Medical Equipment: Patient/Equipment Isolation LCA717STR 6-Pin Surface Mount (1000/Reel) Aerospace Industrial Controls Pin Configuration AC/DC Configuration Switching Characteristics 1 6 + Control of Normally Open Devices Load 2 5 Control Do Not Use Form-A 3 4 Do Not Use Load I F DC Only Configuration 90% 10% 1 6 I LOAD + Control + Load t t on off 2 5 Control Load 3 4 Do Not Use Pb e3 DS-LCA717-R04 1 www.ixysic.comLCA717 INTEGRATED CIRCUITS DIVISION Absolute Maximum Ratings 25C Absolute Maximum Ratings are stress ratings. Stresses in Parameter Ratings Units excess of these ratings can cause permanent damage to Blocking Voltage 30 V P the device. Functional operation of the device at conditions Reverse Input Voltage 5 V beyond those indicated in the operational sections of this Input Control Current 50 mA data sheet is not implied. Peak (10ms) 1 A 1 Input Power Dissipation 100 mW 2 Total Power Dissipation 800 mW Isolation Voltage, Input to Output 3750 V rms Operational Temperature -40 to +85 C Storage Temperature -40 to +125 C 1 Derate linearly 1.33 mW / C 2 Derate linearly 6.67 mW / C Electrical Characteristics 25C Parameter Conditions Symbol Min Typ Max Units Output Characteristics Load Current, Continuous AC/DC Configuration 2A / A rms DC -I -- L DC Configuration 4A DC Peak Load Current t=10ms I -- 5 A LPK P 1 On-Resistance AC/DC Configuration 0.083 0.15 I =1A R - L ON DC Configuration 0.023 0.04 Off-State Leakage Current V =30V I -- 1 A L P LEAK Switching Speeds Turn-On t 0.92 3 on I =5mA, V =10V - ms F L Turn-Off t 0.44 3 off Output Capacitance V =15V, f=1MHz C - 100 - pF L OUT Input Characteristics Input Control Current to Activate I =1A I - 0.115 2 mA L F Input Control Current to Deactivate - I 0.1 - - mA F Input Voltage Drop I =5mA V 0.9 1.2 1.4 V F F Reverse Input Current V =5V I - - 10 A R R Common Characteristics Input to Output Capacitance - C -3 - pF I/O 1 Measurement taken within 1 second of on-time. ESD Rating ESD Rating (Human Body Model) 1000 Volts R04 2 www.ixysic.com