LCC110 350V, 120mA 1-Form-C Relay INTEGRATED CIRCUITS DIVISION Parameters Ratings Units Description Blocking Voltage 350 V LCC110P is a 350V, 120mA, 35 1-Form-C relay. P This device is ideal for applications where a signal Load Current 120 mA / mA rms DC needs to be switched between two different lines. The On-Resistance (max) 35 small 8-lead package makes it an ideal space-saving replacement for a 1-Form-C electromechanical relay (EMR). Featurges 3750V Input/Output Isolation rms 1-Form-C Solid State Relay Approvals Low Drive Power Requirements UL Recognized Component: File E76270 Greater Reliability than Electromechanical Relays CSA Certified Component: Certificate 1175739 FCC Compatible TUV EN 62368-1: Certificate B 082667 0008 VDE Compatible No EMI/RFI Generation Small 8-pin Packages Ordering Information Flammability Rating UL 94 V-0 Part Description Surface Mount Tape & Reel Versions Available LCC110 8-Pin DIP (50/Tube) LCC110P 8-Pin Flatpack (50/Tube) LCC110PTR 8-Pin Flatpack Tape & Reel (1000/Reel) Applications LCC110S 8-Pin Surface Mount (50/Tube) Telecommunications Telecom Switching LCC110STR 8-Pin Surfact Mount Tape & Reel (1000/Reel) Tip/Ring Circuits Modem Switching (Laptop, Notebook, Pocket Size) Pin Configuration Hook Switch Dial Pulsing 1 8 Ground Start Do Not Use Normally Closed Pole Ringing Injection 2 7 + Control Instrumentation 3 6 Multiplexers Control Normally Open Pole Data Acquisition 4 5 Electronic Switching Do Not Use I/O Subsystems Meters (Watt-Hour, Water, Gas) Medical EquipmentPatient/Equipment Isolation Switching Characteristics for a Security 1-Form-C Device Industrial Controls I F 90% 10% Form-A I LOAD t t on off Form-B I LOAD 90% 10% t t off on DS-LCC110-R08 1 www.ixysic.comLCC110 INTEGRATED CIRCUITS DIVISION Absolute Maximum Ratings 25C Absolute Maximum Ratings are stress ratings. Stresses in Parameter Min Max Unit excess of these ratings can cause permanent damage to Blocking Voltage - 350 V P the device. Functional operation of the device at conditions Reverse Input Voltage - 5 V beyond those indicated in the operational sections of this Input control Current - 50 mA data sheet is not implied. Peak (10ms) - 1 A Typical values are characteristic of the device at +25C, 1 Input Power Dissipation - 150 mW and are the result of engineering evaluations. They are 2 Total Power Dissipation - 800 mW provided for information purposes only, and are not part of Isolation Voltage, Input to Output 3750 - V the manufacturing testing requirements. rms Operating Temperature, Ambient -40 +85 C Storage Temperature -40 +125 C 1 Derate linearly 1.33mW / C. 2 Derate output power linearly 6.67mW / C. Electrical Characteristics 25C Parameter Conditions Symbol Min Typ Max Units Output Characteristics Blocking Voltage I =1AV 350 - - V L DRM P 1 Load Current Continuous - I - - 120 mA / mA L rms DC Peak t=10ms I - - 350 mA LPK P 2 On-Resistance I =120mA R -23 35 L ON Off-State Leakage Current V =350V I -- 1 A L P LEAK Switching Speeds Turn-On t -- 4 on I =8mA, V =10V ms F L Turn-Off t -- 4 off Output Capacitance V =50V, f=1MHz C -25 - pF L OUT Input Characteristics Input Control Current to Activate I =120mA I -- 8 mA L F Input Control Current to Deactivate - I 0.4 0.7 - mA F Input Voltage Drop I =10mA V 0.9 1.42 1.56 V F F Reverse Input Current V =5V I -- 10 A R R Common Characteristics Capacitance, Input to Output - C -3 - pF I/O 1 If both poles operate simultaneously, then load current must be derated in order not to exceed package power dissipation value. 2 Measurement taken within one second of on-time. www.ixysic.com 2 R08