LCC120 1-Form-C OptoMOS Relay INTEGRATED CIRCUITS DIVISION Parameters Ratings Units Description Blocking Voltage 250 V P LCC120P is a 250V, 170mA, 20 1-Form-C relay. It Load Current 170 mA / mA is ideal for applications focused on peak load current rms DC On-Resistance (max) 20 handling capablilities. This device is perfect for applications where a signal needs to be switched between two different lines. The Features small 8-lead package makes it an ideal space-saving 3750V Input/Output Isolation rms replacement for a 1-Form-C electromechanical relay 1-Form-C Solid State Relay (EMR). Low Drive Power Requirements (TTL/CMOS Compatible) High Reliability Approvals Arc-Free With No Snubbing Circuits UL Recognized Component: File E76270 FCC Compatible CSA Certified Component: Certificate 1175739 VDE Compatible EN/IEC 60950-1 Certified Component: No EMI/RFI Generation TUV Certificate B 09 07 49410 004 Small 8-pin Package Machine Insertable, Wave Solderable Ordering Information Surface Mount Tape & Reel Versions Available Part Description LCC120 8-Pin DIP (50/Tube) Applications LCC120S 8-Pin Surface Mount (50/Tube) Telecommunications LCC120STR 8-Pin Surfact Mount Tape & Reel (1000/Reel) Telecom Switching Tip/Ring Circuits Modem Switching (Laptop, Notebook, Pocket Size) Pin Configuration Hook Switch AC/DC Configuration Dial Pulsing 1 8 Ground Start Do Not Use Normally Closed Pole Ringing Injection 2 7 + Control Instrumentation 3 6 Multiplexers Control Normally Open Pole Data Acquisition 4 5 Electronic Switching Do Not Use I/O Subsystems Meters (Watt-Hour, Water, Gas) Medical EquipmentPatient/Equipment Isolation Switching Characteristics for a Security Form-C Device Aerospace Industrial Controls I F 90% 10% Form-A I LOAD t t on off Form-B I LOAD 90% 10% t t off on Pb e3 DS-LCC120-R09 1 www.ixysic.comLCC120 INTEGRATED CIRCUITS DIVISION Absolute Maximum Ratings 25C Absolute Maximum Ratings are stress ratings. Stresses in Parameter Min Max Unit excess of these ratings can cause permanent damage to Blocking Voltage - 250 V P the device. Functional operation of the device at conditions Reverse Input Voltage - 5 V beyond those indicated in the operational sections of this Input control Current - 50 mA data sheet is not implied. Peak (10ms) - 1 A 1 Input Power Dissipation - 150 mW 2 Total Power Dissipation - 800 mW Isolation Voltage, Input to Output 3750 - V rms Operating Temperature -40 +85 C Storage Temperature -40 +125 C 1 Derate linearly 1.33mW / C. 2 Derate linearly 6.67mW / C. Electrical Characteristics 25C Parameter Conditions Symbol Min Typ Max Units Output Characteristics Load Current Continuous, AC/DC Con guration - I - - 170 mA / mA L rms DC Peak t=10ms I -- 400 mA LPK P On-Resistance, AC/DC Con guration I =170mA R -16 20 L ON Off-State Leakage Current V =250V I -- 1 A L P LEAK Switching Speeds Turn-On t -- 5 on I =10mA, V =10V ms F L Turn-Off t -- 5 off Output Capacitance V =50V, f=1MHz C -50 - pF L OUT Input Characteristics Input Control Current to Activate I =170mA I - - 10 mA L F Input Control Current to Deactivate - I 0.4 0.7 - mA F Input Voltage Drop I =10mA V 0.9 1.2 1.4 V F F Reverse Input Current V =5V I -- 10 A R R Common Characteristics Capacitance, Input to Output - C -3 - pF I/O R09 2 www.ixysic.com