PAA110L 400V, 150mA Dual Single-Pole Normally Open Relays INTEGRATED CIRCUITS DIVISION Parameters Ratings Units Description Blocking Voltage 400 V PAA110L is a dual 400V, 150mA, 25 1-Form-A P Load Current 150 mA / mA (normally open) relay. This performance leader rms DC provides high peak load voltage handling capability On-Resistance (max) 25 and improved peak load current handling. Integrated current-limiting circuitry limits current to 280mA at room temperature. Features Current Limiting 3750V Input/Output Isolation Approvals rms Low Drive Power Requirements UL Recognized Component: File E76270 100% Solid State CSA Certified Component: Certificate 1175739 No EMI/RFI Generation TUV EN 62368-1: Certificate B 082667 0008 Small 8-Pin DIP Package Flammability Rating UL 94 V-0 Surface Mount and Tape Reel Versions Available. Ordering Information Part Description PAA110L 8-Pin DIP (50/Tube) Applications PAA110PL 8-Pin SOIC (Flatpack) (50/Tube) Telecommunications PAA110PLTR 8-Pin SOIC (Flatpack) (1000/Reel) Instrumentation PAA110LS 8-Pin Surface Mount (50/Tube) Multiplexers PAA110LSTR 8-Pin Surface Mount (1000/Reel) Data Acquisition Electronic Switching I/O Subsystems Pin Configuration Meters (Watt-Hour, Water, Gas) Medical Equipment-Patient/Equipment Isolation 1 8 + Control - Switch 1 Security Load - Switch 1 Industrial Controls 2 7 Control - Switch 1 Load - Switch 1 3 6 + Control - Switch 2 Load - Switch 2 4 5 Control - Switch 2 Load - Switch 2 Switching Characteristics of Normally Open (Form A) Devices Form-A I F 90% 10% I LOAD t t on off DS-PAA110L-R09 1 www.ixysic.comPAA110L INTEGRATED CIRCUITS DIVISION Absolute Maximum Ratings 25C Absolute Maximum Ratings are stress ratings. Stresses in Parameter Ratings Units excess of these ratings can cause permanent damage to Blocking Voltage 400 V P the device. Functional operation of the device at conditions Reverse Input Voltage 5 V beyond those indicated in the operational sections of this Input Control Current 50 mA data sheet is not implied. Peak (10ms) 1 A 1 Typical values are characteristic of the device at +25C, Input Power Dissipation 150 mW 2 and are the result of engineering evaluations. They are Total Power Dissipation 800 mW provided for information purposes only, and are not part of Isolation Voltage Input to Output 3750 V rms the manufacturing testing requirements. Operational Temperature, Ambient -40 to +85 C Storage Temperature -40 to +125 C 1 Derate linearly 1.33 mW / C 2 Derate output power linearly 6.67 mW / C Electrical Characteristics 25C Parameter Conditions Symbol Min Typ Max Units Output Characteristics Blocking Voltage I =1AV 400 - - V L DRM P 1 Load Current Continuous - I - - 150 L mA / mA rms DC Current Limiting - I 190 235 280 CL 2 On-Resistance I =150mA R -18 25 L ON Off-State Leakage Current V =400V I -- 1 A L LEAK Switching Speeds Turn-On t - 0.3 1 on I =5mA, V =10V ms F L Turn-Off t - 0.058 0.5 off Output Capacitance I =0mA, V=50V, f=1MHz C -25- pF F OUT Input Characteristics Input Control Current to Activate I =150mA I -- 5 mA L F Input Control Current to Deactivate - I 0.4 - - mA F Input Voltage Drop I =5mA V 0.9 1.36 1.5 V F F Reverse Input Current V =5V I -- 10 A R R Common Characteristics Input to Output Capacitance V =0V, f=1MHz C -3- pF IO IO 1 If both poles operate simultaneously load current must be derated in order not to exceed the package power dissipation value. 2 Measurement taken within one second of on-time. 2 R09 www.ixysic.com