PBA150 Dual Single-Pole OptoMOS Relay INTEGRATED CIRCUITS DIVISION Parameter Ratings Units Description Blocking Voltage 250 V PBA150 comprises two independent 250V, 250mA, P 7 solid state relays: one single-pole, normally Load Current 250 mA / mA rms DC open (1-Form-A) relay and one single-pole, normally On-Resistance (max) 7 closed (1-Form-B) relay. Featuring low on-resistance, the PBA150 is designed Features to provide an ideal solution where a complementary 3750V Input/Output Isolation rms Form-A/Form-B relay pair is required. Low Drive Power Requirements (TTL/CMOS Compatible) Approvals High Reliability UL Recognized Component: File E76270 Arc-Free With No Snubbing Circuits CSA Certified Component: Certificate 1175739 FCC Compatible EN/IEC 60950-1 Certified Component: VDE Compatible TUV Certificate B 09 07 49410 004 No EMI/RFI Generation Small 8-Pin Package Ordering Information Machine Insertable, Wave Solderable Surface Mount, Tape & Reel Versions Available Part Description PBA150 8-Lead DIP (50/Tube) PBA150S 8-Lead Surface Mount (50/Tube) Applications PBA150STR 8-Lead Surface Mount (1,000/Reel) Telecommunications Telecom Switching Pin Configuration Tip/Ring Circuits Modem Switching (Laptop, Notebook, Pocket Size) AC/DC Configuration Hook Switch 1 8 + Control - Normally Closed Dial Pulsing Normally Closed Pole 2 7 Ground Start - Control - Normally Closed 3 6 Ringing Injection + Control - Normally Open Normally Open Pole Instrumentation 4 5 - Control - Normally Open Multiplexers Data Acquisition Switching Characteristics Electronic Switching of Normally Open Devices I/O Subsystems Meters (Watt-Hour, Water, Gas) Form-A Medical Equipment-Patient/Equipment Isolation Security I F Aerospace 90% Industrial Controls 10% I LOAD t t on off Switching Characteristics of Normally Closed Devices Form-B I F I LOAD 90% 10% t t off on Pb e3 DS-PBA150-R05 1 www.ixysic.comPBA150 INTEGRATED CIRCUITS DIVISION Absolute Maximum Ratings 25C Absolute Maximum Ratings are stress ratings. Stresses in Parameter Ratings Units excess of these ratings can cause permanent damage to Blocking Voltage 250 V P the device. Functional operation of the device at conditions Reverse Input Voltage 5 V beyond those indicated in the operational sections of this Input Control Current 50 mA data sheet is not implied. Peak (10ms) 1 A 1 Input Power Dissipation 150 mW 2 Total Power Dissipation 800 mW Isolation Voltage, Input to Output 3750 V rms Operational Temperature -40 to +85 C Storage Temperature -40 to +125 C 1 Derate linearly 1.33 mW / C 2 Derate linearly 6.67 mW / C Electrical Characteristics 25C Parameter Conditions Symbol Min Typ Max Units Output Characteristics 1 Load Current Continuous, AC/DC Configuration - I - - 250 mA / mA L rms DC Peak 10ms I - - 500 mA LPK P On-Resistance I =250mA R -- 7 L ON Off-State Leakage Current V =250V I -- 1 A L P LEAK Switching Speeds Turn-On t - - 2.5 on I =5mA, V =10V ms F L Turn-Off t - - 2.5 off Output Capacitance V =50V, f=1MHz C - 110 - pF L OUT Input Characteristics Input Control Current to Activate I =250mA I -- 5 mA L F Input Control Current to Deactivate - I 0.4 0.7 - mA F Input Voltage Drop I =5mA V 0.9 1.2 1.4 V F F Reverse Input Current V =5V I -- 10 A R R Common Characteristics Capacitance, Input to Output - C -3 - pF I/O 1 If both poles operate simultaneously, then the load current must be derated in order not to exceed the package power dissipation value. R05 2 www.ixysic.com