PBB190 400V, 130mA Dual Single-Pole Normally Closed Relay INTEGRATED CIRCUITS DIVISION Parameter Ratings Units Description Blocking Voltage 400 V PBB190 is a dual single-pole, normally closed P (1-Form-B) solid state relay with two independently Load Current 130 mA / mA rms DC controlled switches that use optically coupled On-Resistance (max) 25 MOSFET technology to provide 5000V of input to rms output isolation. Features Its optically coupled outputs, which use the patented 5000V Input/Output Isolation OptoMOS architecture, are controlled by a highly rms Low Drive Power Requirements efficient infrared LED. Greater Reliability than Electromechanical Relays No EMI/RFI Generation Dual single-pole OptoMOS relays provide a more Small 8-Pin Package compact design solution than discrete single-pole Flammability Rating UL 94 V-0 relays in a variety of applications by incorporating Surface Mount, Tape & Reel Version Available both relays in a single 8-pin package. Approvals Applications UL Recognized Component: File E76270 Telecommunications TUV EN 62368-1: Certificate B 082667 0008 Telecom Switching Tip/Ring Circuits Modem Switching (Laptop, Notebook, Pocket Size) Ordering Information Hook Switch Part Description Dial Pulsing PBB190 8-Lead DIP (50/Tube) Ground Start PBB190S 8-Lead Surface Mount (50/Tube) Ringing Injection Instrumentation PBB190STR 8-Lead Surface Mount (1,000/Reel) Multiplexers Data Acquisition Electronic Switching Pin Configuration I/O Subsystems 1 8 Meters (Watt-Hour, Water, Gas) + Control - Switch 1 Load - Switch 1 Medical Equipment-Patient/Equipment Isolation 2 7 - Control - Switch 1 Security Load - Switch 1 3 6 Industrial Controls + Control - Switch 2 Load - Switch 2 4 5 - Control - Switch 2 Load - Switch 2 Switching Characteristics of Normally Closed Devices Form-B I F I LOAD 90% 10% t t off on DS-PBB190-R04 1 www.ixysic.comPBB190 INTEGRATED CIRCUITS DIVISION Absolute Maximum Ratings 25C Absolute Maximum Ratings are stress ratings. Stresses in Parameter Ratings Units excess of these ratings can cause permanent damage to Blocking Voltage 400 V P the device. Functional operation of the device at conditions Reverse Input Voltage 5 V beyond those indicated in the operational sections of this LED Forward Current 50 mA data sheet is not implied. Peak (10ms) 1 A 1 Typical values are characteristic of the device at +25C, Input Power Dissipation 150 mW and are the result of engineering evaluations. They are 2 Total Power Dissipation 800 mW provided for information purposes only, and are not part of Isolation Voltage, Input to Output the manufacturing testing requirements. 5000 V rms (60 Seconds) ESD Rating, Human Body Model 8 kV Operational Temperature, Ambient -40 to +85 C Storage Temperature -40 to +125 C 1 Derate linearly 1.33 mW / C 2 Derate output power linearly 6.67 mW / C Electrical Characteristics 25C Parameter Conditions Symbol Min Typ Max Units Output Characteristics Blocking Voltage I =1AV 400 - - V L DRM P 1 Load Current Continuous I =0mA - - 130 mA / mA F rms DC I L Peak I =0mA, t=10ms - - 400 mA F P 2 On-Resistance I =0mA, I =130mA R -- 25 F L ON Off-State Leakage Current I =2mA, V =400V I -- 1 A F L P LEAK Switching Speeds Turn-On t -- 1 on I =5 mA, V =10V ms F L Turn-Off t - - 2.5 off Output Capacitance I =5mA, V =50V, f=1MHz C -11 - pF F L OUT Input Characteristics LED Forward Current 3 To Activate I =130mA - 0.38 2 L I mA F To Deactivate - 0.2 0.35 - Input Voltage Drop I =5mA V 0.9 1.36 1.5 V F F Reverse Input Current V =5V I - - 10 A R R Common Characteristics Input to Output Capacitance V =0V, f=1MHz C -3 - pF IO IO 1 If both poles operate simultaneously, then the load current must be derated so that the package power dissipation value is not exceeded. 2 Measurement taken within 1 second of on-time. 3 For high temperature operation (>60C), a minimum LED drive current of 4mA is recommended. 2 R04 www.ixysic.com