PLA160 Single Pole, Normally Open OptoMOS Relay INTEGRATED CIRCUITS DIVISION Parameter Rating Units Description Maximum Turn-On/Turn-Off Times 50 s PLA160 is a 300V, 50mA, 100 1-Form-A relay. This performance leader features the fastest switching Blocking Voltage 300 V P speed (50s) available in an OptoMOS relay. Load Current 50 mA / mA rms DC On-Resistance (max) 100 Approvals UL Recognized Component: File E76270 Features CSA Certified Component: Certificate 1175739 Fastest Switching OptoMOS Relay, 50s EN/IEC 60950 Certified Component: 3750V Input/Output Isolation rms TUV Certificate B 12 11 82667 002 Low Drive Power Requirements (TTL/CMOS Compatible) No Moving Parts Ordering Information High Reliability Part Number Description Arc-Free With No Snubbing Circuits PLA160 6-Pin DIP (50/Tube) FCC Compatible PLA160S 6-Pin Surface Mount (50/Tube) No EMI/RFI Generation PLA160STR 6-Pin Surface Mount (1,000/Reel) Small 6-Pin DIP Package Machine Insertable, Wave Solderable Surface Mount Tape & Reel Version Available Flammability Classification Rating of V-0 Pin Configuration AC/DC Configuration 1 6 Applications + Control Load 2 5 Instrumentation Control Do Not Use Multiplexers 3 4 Do Not Use Load Data Acquisition Electronic Switching DC Only Configuration I/O Subsystems 1 6 Meters (Watt-Hour, Water, Gas) + Control + Load Medical EquipmentPatient/Equipment Isolation 2 5 Control Load Security Systems 3 4 Do Not Use Aerospace Industrial Controls Reed Relay Replacement Switching Characteristics of Normally Open (Form A) Devices Form-A I F 90% 10% I LOAD t t on off Pb e3 DS-PLA160-R06 1 www.ixysic.comPLA160 INTEGRATED CIRCUITS DIVISION Absolute Maximum Ratings 25C Absolute Maximum Ratings are stress ratings. Stresses in Parameter Ratings Units excess of these ratings can cause permanent damage to the Blocking Voltage 300 V P device. Functional operation of the device at conditions beyond Reverse Input Voltage 5 V those indicated in the operational sections of this data sheet is Input Control Current 50 mA not implied. Peak (10ms) 1 A 1 Input Power Dissipation 150 mW 2 Total Power Dissipation 800 mW Isolation Voltage, Input to Output 3750 V rms Operational Temperature -40 to +85 C Storage Temperature -40 to +125 C 1 Derate linearly 1.33 mW / C 2 Derate linearly 6.67 mW / C Electrical Characteristics 25C Parameter Conditions Symbol Min Typ Max Units Output Characteristics Load Current (Continuous) AC/DC Configuration - - 50 mA / mA rms DC -I L DC Configuration - - 80 mA DC Peak Load Current t=10ms I - - 200 mA LPK P On-Resistance AC/DC Configuration I =50mA - 60 100 F R ON DC Configuration I =80mA - 15 30 F Off-State Leakage Current V =300V -- 25 L I nA LEAK V =100V - 1 10 L Switching Speeds Turn-On t 25 on I =10mA, V =10V - 50 s F L Turn-Off t 42 off Output Capacitance 50V, f=1mHz C -3 - pF OUT Input Characteristics Input Control Current to Activate I =50mA I - 1.35 10 mA L F Input Control Current to Deactivate - I 0.4 1.25 - mA F Input Voltage Drop I =10mA V 1.8 2.4 2.8 V F F Reverse Input Current V =5V I - - 10 A R R Common Characteristics Input to Output Capacitance - C -3 - pF I/O R06 2 www.ixysic.com