PLA172P 800V, 100mA Single-Pole Normally Open Relay INTEGRATED CIRCUITS DIVISION Parameter Rating Units Description Blocking Voltage 800 V P IXYS Integrated Circuits PLA172P is a single-pole, Load Current 100 mA rms normally-open (1-Form-A) Solid State Relay, rated 85 mA DC for operation up to 105C, that uses optically coupled On-Resistance (max) 50 MOSFET technology to provide an en hanced input to Input Control Current 2 mA output isolation of 5000V . rms The unique device pinout provides more than 6.8mm of pad-to-pad separation between the high voltage Features output pins. Guaranteed Specifications at 105C Control of the optically coupled output is by the input -40C to +105C Operational Temperature Range infrared LED. The PLA172P is designed to replace 5mA Input Control Current Over Operating electromechanical relays, and provides bounce-free Temperature Range switching in a compact, surface-mount package. 800V Blocking Voltage P 6.8mm Pad-to-Pad Separation of Output Pins 5000V Input/Output Isolation Approvals rms Small Surface Mount Package UL Recognized Component: File E76270 No EMI/RFI Generation TUV EN 62368-1: Certificate B 082667 0008 Flammability Rating UL 94 V-0 Ordering Information Applications Part Description Industrial Controls PLA172P 6-Pin (8-Pin Body) Flatpack (50/Tube) Instrumentation PLA172PTR 6-Pin (8-Pin Body) Flatpack, Tape & Reel (1000/Reel) Multiplexers Data Acquisition Pin Configuration Electronic Switching I/O Subsystems 1 8 Meters (Watt-Hour, Water, Gas) NC Load Medical EquipmentPatient/Equipment Isolation 2 + Control 3 Control 5 4 NC Load Switching Characteristics of Normally-Open Devices Form-A I F 90% 10% I LOAD t t on off DS-PLA172P-R03 1 www.ixysic.comPLA172P INTEGRATED CIRCUITS DIVISION Absolute Maximum Ratings ( 25C Unless otherwise noted) Absolute Maximum Ratings are stress ratings. Stresses in Parameter Ratings Units excess of these ratings can cause permanent damage to the Blocking Voltage (-40C to +105C) 800 V P device. Functional operation of the device at conditions beyond Reverse Input Voltage 5 V those indicated in the operational sections of this data sheet is Input Control Current 50 mA not implied. Peak (10ms) 1 A 1 Input Power Dissipation 150 mW Typical values are characteristic of the device at the specified Output Power Dissipation temperatures and are the result of engineering evaluations. 2 AC Load Current 890 mW They are provided for information purposes only and are not 3 DC Load Current 667 part of the manufacturing testing requirements. Isolation Voltage, Input to Output (60 Seconds) 5000 V rms Operational Temperature, Ambient -40 to +105 C Storage Temperature -40 to +125 C 1 Derate linearly 1.33 mW / C 2 Derate output power linearly 8.9 mW / C 3 Derate output power linearly 6.67 mW / C Electrical Characteristics Parameter Conditions Symbol Min Typ Max Units Output Characteristics 25C Blocking Voltage I =1AV 800 - - V L DRM P Load Current 1 Continuous, AC - - 100 mA rms I =2mA I 2 F L Continuous, DC - - 85 mA DC Peak I =2mA, t=10ms I - - 350 mA F LPK P 3 On-Resistance I =2mA, I = 100mA -37 50 F L R ON I =2mA, I =1mA - 57 85 F L Off-State Leakage Current V =800V I -- 1 A L LEAK Switching Speeds Turn-On t - 1.2 5 on I =5mA, I =100mA ms F L Turn-Off t - 0.5 5 off Output Capacitance I =0mA, V =20V, f=1MHz C -10 - pF F L OUT Output Characteristics 105C 3 On-Resistance I =5mA, I =30mA - 70 110 F L R ON I =5mA, I =1mA - 110 140 F L Off-State Leakage Current V =800V I -- 5 A L LEAK Switching Speeds Turn-On t -- 10 on I =5mA, I =30mA ms F L Turn-Off t -- 10 off Input Characteristics 25C 4 Input Control Current to Activate I =100mA I - 0.35 2 mA L F Input Control Current to Deactivate - I 0.05 - - mA F Input Voltage Drop I =5mA V 0.9 1.36 1.5 V F F Reverse Input Current V =5V I -- 10 A R R Input Characteristics 105C Input Control Current to Activate I =30mA I -- 5 mA L F Common Characteristics 25C Input to Output Capacitance V =0V, f=1MHz C - 1 -pF IO IO 1 o o Load derates linearly from 100mA 25 C to 44mA 105 C (0.7mA/C). 2 Load derates linearly from 85mA 25C to 38mA 105C (0.59mA/C). 3 Measurement taken within 1 second of on-time. 4 o For applications requiring high temperature operation (greater than 60 C) a minimum LED drive current of 5mA is recommended. 2 R03 www.ixysic.com