PLA192 Single Pole, Normally Open OptoMOS Relay INTEGRATED CIRCUITS DIVISION Parameters Ratings Units Description Blocking Voltage 600 V IXYS Integrated Circuits Division s PLA192 is a P single-pole, normally open (1-Form-A) solid state Load Current 150 mA / mA rms DC relay that provides 5000V of input to output On-Resistance (max) 22 rms isolation. LED Current to Operate 5 mA In addition to all the features and benefits of the PLA192, the PLA192E meets the partial discharge Features demands of DIN EN 60747-5-5 (previously VDE PLA192E is 100% Tested for Partial Discharge: 0884). DIN EN 60747-5-5 All versions of the PLA192 can be used to replace 5000V Input/Output Isolation rms mechanical relays, while offering the superior Low Drive Power Requirements (TTL/CMOS reliability associated with semiconductor devices. Compatible) Optically coupled outputs that use the patented No Moving Parts OptoMOS architecture are controlled by a highly High Reliability efficient GaAIAs infrared LED. Because they have Arc-Free With No Snubbing Circuits no moving parts, they offer bounce-free switching in No EMI/RFI Generation more compact surface mount or thru-hole packages. Small 6-Pin Package Machine Insertable, Wave Solderable Approvals UL Recognized Component: File E76270 Applications CSA Certified Component: Certificate 1175739 Instrumentation EN/IEC 60950-1 Certified Component: Multiplexers TUV Certificate B 12 11 82667 002 Data Acquisition DIN EN 60747-5-5 Certified Suffix Only) Electronic Switching VDE Certificate 40036603 I/O Subsystems Meters (Watt-Hour, Water, Gas) Ordering Information Medical Equipment: Patient/Equipment Isolation Aerospace Part Description Industrial Controls PLA192E 6-Pin DIP (50/Tube) PLA192ES 6-Pin Surface Mount (50/Tube) PLA192ESTR 6-Pin Surface Mount (1000/Reel) Pin Configuration PLA192 6-Pin DIP (50/Tube) AC/DC Configuration PLA192S 6-Pin Surface Mount (50/Tube) PLA192STR 6-Pin Surface Mount (1000/Reel) 1 6 + Control Load 2 5 - Control Do Not Use Switching Characteristics of Normally Open Devices 3 4 Do Not Use Load Form-A DC Only Configuration 1 6 + Control + Load I F 2 5 - Control - Load 3 4 90% Do Not Use 10% I LOAD t t on off Pb e3 DS-PLA192-R07 1 www.ixysic.comPLA192 INTEGRATED CIRCUITS DIVISION Absolute Maximum Ratings 25C (Unless Otherwise Noted) Absolute Maximum Ratings are stress ratings. Stresses in Parameter Rating Units excess of these ratings can cause permanent damage to the Blocking Voltage 600 V P device. Functional operation of the device at conditions beyond Reverse Input Voltage 5 V those indicated in the operational sections of this data sheet is Input Control Current 50 mA not implied. Peak (10ms) 1 A 1 Input Power Dissipation 150 mW 2 Total Package Dissipation 800 mW Isolation Voltage, Input to Output 5000 V rms (60 Seconds) ESD Rating, Human Body Model 4 kV Operational Temperature -40 to +85 C Storage Temperature -40 to +125 C 1 Derate linearly 1.33 mW / C 2 Derate linearly 6.67 mW / C Electrical Characteristics 25C (Unless Otherwise Noted) Parameters Conditions Symbol Min Typ Max Units Output Characteristics Load Current Continuous, AC/DC Configuration - - - 150 mA / mA rms DC I L Continuous, DC-Only Configuration - - - 220 mA DC Peak t=10ms I - - 400 mA LPK P On-Resistance AC/DC Configuration I =150mA - 13.3 22 L R ON DC-Only Configuration I =220mA - 4.15 8 L Off-State Leakage Current V =600V I -- 1 A L P LEAK Switching Speeds Turn-On t -- 5 on I =5mA, V =10V ms F L Turn-Off t -- 5 off Output Capacitance V =50V, f=1MHz C -10 - pF L OUT Input Characteristics Input Control Current to Activate I =100mA I - 0.22 5 mA L F Input Control Current to Deactivate - I 0.1 0.21 - mA F Input Voltage Drop I =5mA V 0.9 1.2 1.4 V F F Reverse Input Current V =5V I -- 10 A R R Common Characteristics Input to Output Capacitance - C -3 - pF I/O PLA192E Safety and Insulation Ratings Parameters Conditions Symbol Min Max Units Pollution Degree 2 according to DIN VDE 0109 - ---- Highest Allowable Over-Voltage Transient Voltage V 7071 - V IOTM P Maximum Working Insulation Voltage Recurring Voltage V 1000 - V IORM P Partial Discharge Test Voltage DIN EN 60747-5-5 Method B V - 1875 V PR P Isolation Test Voltage - V - 5000 V ISO rms Creepage Distance - - 7.6 - mm Clearance Distance - - 7.6 - mm R07 2 www.ixysic.com