PLA194 Single-Pole, Normally Open OptoMOS Relay INTEGRATED CIRCUITS DIVISION Parameters Ratings Units Description Blocking Voltage 600 V The PLA194 is a single-pole, normally open P (1-Form-A) solid state relay that uses optically Load Current 130 mA / mA rms DC coupled relay technology to provide an enhanced On-Resistance (max) 35 5000V isolation barrier between the input and the rms output of the relay. Its optically coupled outputs, which use the patented Features OptoMOS architecture, are controlled by a highly 5000V Input/Output Isolation efficient GaAIAs infrared LED. rms Low Drive Power Requirements (TTL/CMOS Compatible) Approvals No Moving Parts UL-Recognized Component: File Number E76270 High Reliability CSA Certified Component: Certificate 1117539 Arc-Free With No Snubbing Circuits Certified to EN/IEC 60950-1: No EMI/RFI Generation TUV Certificate B 10 05 49410 006 Small 6-Pin Package Machine Insertable, Wave Solderable Ordering Information Part Description Applications PLA194 6-Pin DIP (50/Tube) Sensor Circuitry PLA194S 6-Pin Surface Mount (50/Tube) Instrumentation PLA194STR 6-Pin Surface Mount (1000/Reel) Multiplexers Data Acquisition Electronic Switching Pin Configuration I/O Subsystems AC/DC Configuration Meters (Watt-Hour, Water, Gas) 1 6 Medical Equipment: Patient/Equipment Isolation + Control Load Aerospace 2 5 - Control Do Not Use Industrial Controls 3 4 NC Load DC-Only Configuration 1 6 + Control + Load 2 5 - Control - Load 3 4 NC Switching Characteristics of Normally Open Devices Form-A I F 90% 10% I LOAD t t on off Pb e3 DS-PLA194-R02 1 www.ixysic.comPLA194 INTEGRATED CIRCUITS DIVISION Absolute Maximum Ratings 25C Absolute Maximum Ratings are stress ratings. Stresses in Parameter Min Max Units excess of these ratings can cause permanent damage to Blocking Voltage - 600 V P the device. Functional operation of the device at conditions Reverse Input Voltage - 5 V beyond those indicated in the operational sections of this Input Control Current - 50 mA data sheet is not implied. Peak (10ms) - 1 A 1 Input Power Dissipation - 150 mW 2 Total Package Dissipation - 800 mW ESD Rating, Human Body Model 8 - kV Isolation Voltage, Input to Output 5000 - V rms Operational Temperature -40 85 C Storage Temperature -40 125 C 1 Derate linearly 1.33 mW / C 2 Derate linearly 6.67 mW / C Electrical Characteristics 25C Parameters Conditions Symbol Min Typ Max Units Output Characteristics 1 Load Current Continuous, AC/DC Configuration - - - 130 mA / mA rms DC I L Continuous, DC-Only Configuration - - - 200 mA DC Peak t=10ms I - - 400 mA LPK P 2 On-Resistance AC/DC Configuration I =130mA -26 35 L R ON DC-Only Configuration I =200mA - - 18 L Off-State Leakage Current V =600V I -- 1 A L P LEAK Switching Speeds Turn-On t - 0.85 3 on I =5mA, V =10V ms F L Turn-Off t - 0.46 2 off Output Capacitance V =50V, f=1MHz C -5 - pF L OUT Input Characteristics 3 Input Control Current to Activate I =130mA I - 0.44 2 mA L F Input Control Current to Deactivate - I 0.1 - - mA F Input Voltage Drop I =5mA V 0.9 1.2 1.4 V F F Reverse Input Current V =5V I -- 10 A R R Common Characteristics Input to Output Capacitance - C -3 - pF I/O 1 Load current derates linearly from 130mA 25C to 65mA 85C. 2 Measurement taken within 1 second of on-time. 3 For applications requiring high temperature operation (greater than 60C), a LED drive current of 3mA is recommended. R02 2 www.ixysic.com