PLB190 Single-Pole, Normally Closed OptoMOS Relay INTEGRATED CIRCUITS DIVISION Parameter Rating Units Description Blocking Voltage 400 V The PLB190 is a single-pole, normally closed P (1-Form-B) solid state relay that uses optically Load Current 130 mA / mA rms DC coupled relay technology to provide an enhanced On-Resistance (max) 25 5000V isolation barrier between the input and rms output of the relay. Features Its optically coupled outputs, which use the patented 5000V Input/Output Isolation rms OptoMOS architecture, are controlled by a highly Low Drive Power Requirements efficient GaAIAs infrared LED. (TTL/CMOS Compatible) No Moving Parts High Reliability Approvals Arc-Free With No Snubbing Circuits UL Recognized Component: File E76270 FCC Compatible CSA Certified Component: Certificate 1175739 VDE Compatible EN/IEC 60950-1 Certified Component: No EMI/RFI Generation TUV Certificate B 09 07 49410 004 Small 6-Pin Package Machine Insertable, Wave Solderable Surface Mount Tape & Reel Version Available Ordering Information Part Number Description Applications PLB190 6-Pin DIP (50/Tube) Telecommunications PLB190S 6-Pin Surface Mount (50/Tube) Telecom Switching PLB190STR 6-Pin Surface Mount (1,000/Reel) Tip/Ring Circuits Modem Switching (Laptop, Notebook, Pocket Size) Dial Pulsing Instrumentation Pin Configuration Multiplexers Data Acquisition AC/DC Configuration DC-Only Configuration Electronic Switching 1 1 6 6 + Control + Control Load + Load I/O Subsystems 2 5 2 5 - Control - Control - Load Do Not Use Meters (Watt-Hour, Water, Gas) 3 4 3 4 NC Load NC Medical EquipmentPatient/Equipment Isolation Security Systems Aerospace Industrial Controls Switching Characteristics of Normally Closed Devices Form-B I F I LOAD 90% 10% t t off on Pb e3 DS-PLB190-R03 1 www.ixysic.comPLB190 INTEGRATED CIRCUITS DIVISION Absolute Maximum Ratings 25C Absolute Maximum Ratings are stress ratings. Stresses in Parameter Ratings Units excess of these ratings can cause permanent damage to Blocking Voltage 400 V P the device. Functional operation of the device at conditions Reverse Input Voltage 5 V beyond those indicated in the operational sections of this Input Control Current 50 mA data sheet is not implied. Peak (10ms) 1 A 1 Input Power Dissipation 150 mW 2 Total Power Dissipation 800 mW Isolation Voltage, Input to Output (60 sec.) 5000 V rms Operational Temperature -40 to +85 C Storage Temperature -40 to +125 C 1 Derate linearly 1.33 mW / C 2 Derate linearly 6.67 mW / C Electrical Characteristics 25C (Unless Otherwise Noted) Parameter Conditions Symbol Min Typ Max Units Output Characteristics Load Current (Continuous) AC/DC Configuration - - 130 mA / mA rms DC I =0mA I F L DC Configuration - - 250 mA DC Peak Load Current t=10ms I - - 400 mA LPK P 1 On-Resistance AC/DC Configuration I =0mA, I =130mA -- 25 F L R ON DC Configuration I =0mA, I =250mA - - 10 F L Off-State Leakage Current I =2mA, V =400V I -- 1 A F L P LEAK Switching Speeds Turn-On t -- 1 on I =5 mA, V =10V ms F L Turn-Off t - - 2.5 off Output Capacitance I =5mA, V =50V, f=1MHz C -11 - pF F L OUT Input Characteristics 2 Input Control Current to Activate I =130mA I - 0.38 2 mA L F Input Control Current to Deactivate - I 0.2 0.35 - mA F Input Voltage Drop I =5mA V 0.9 1.2 1.4 V F F Reverse Input Current V =5V I - - 10 A R R Common Characteristics Input to Output Capacitance - C -3 - pF I/O 1 Measurement taken within 1 second of on-time. 2 For high temperature operation (>60C), a LED current of 4mA is recommended. R03 2 www.ixysic.com