XAA117 Dual Single-Pole, Normally Open OptoMOS Relay INTEGRATED CIRCUITS DIVISION Parameter Ratings Units Description Blocking Voltage 60 V The XAA117 is a dual, single-pole, normally open P (1-Form-A) Solid State Relay with two independently Load Current 150 mA / mA rms DC controlled, optically coupled MOSFET switches that On-Resistance (max) 16 feature 3750V of input to output isolation. LED Current to Operate 1 mA rms The optically coupled outputs, which use the patented OptoMOS architecture, are controlled by a highly efficient GaAIAs infrared LED. Features Low Input Control Current: 1mA This dual single-pole OptoMOS relay provides a more 3750V Input/Output Isolation rms compact design solution than discrete single-pole Low Drive Power Requirements (TTL/CMOS relays in a variety of applications, and saves board Compatible) space by incorporating both switches in a single 8-Pin Arc-Free With No Snubbing Circuits package. FCC Compatible VDE Compatible No EMI/RFI Generation Approvals Machine Insertable, Wave Solderable UL Recognized Component: File E76270 Surface Mount Tape & Reel Version Available CSA Certified Component: Certificate 1175739 EN/IEC 60950-1 Compliant Applications Security Ordering Information Passive Infrared Detectors (PIR) Part Description Data Signaling XAA117 8-Pin DIP (50/Tube) Sensor Circuitry XAA117S 8-Pin Surface Mount (50/Tube) Instrumentation XAA117STR 8-Pin Surface Mount (1,000/Reel) Multiplexers Data Acquisition XAA117P 8-Pin Flat Pack (50/Tube) Electronic Switching XAA117PTR 8-Pin Flat Pack (1,000/Reel) I/O Subsystems Meters (Watt-Hour, Water, Gas) Pin Configuration Medical Equipment-Patient/Equipment Isolation Security 1 8 + Control - Switch 1 Load - Switch 1 Aerospace 2 7 Control - Switch 1 Load - Switch 1 Industrial Controls 3 6 + Control - Switch 2 Load - Switch 2 4 5 Control - Switch 2 Load - Switch 2 Switching Characteristics of Normally Open Devices Form-A I F 90% 10% I LOAD t t on off Pb e 3 DS-XAA117-R03 1 www.ixysic.comXAA117 INTEGRATED CIRCUITS DIVISION Absolute Maximum Ratings 25C Absolute Maximum Ratings are stress ratings. Stresses in Parameter Ratings Units excess of these ratings can cause permanent damage to Blocking Voltage 60 V P the device. Functional operation of the device at conditions Reverse Input Voltage 5 V beyond those indicated in the operational sections of this Input Control Current 50 mA data sheet is not implied. Peak (10ms) 1 A 1 Input Power Dissipation 150 mW 2 Total Power Dissipation 800 mW Isolation Voltage, Input to Output 3750 V rms Operational Temperature -40 to +85 C Storage Temperature -40 to +125 C 1 Derate linearly 1.33 mW / C 2 Derate linearly 6.67 mW / C Electrical Characteristics 25C Parameter Conditions Symbol Min Typ Max Units Output Characteristics Load Current 1 Continuous -I - - 150 mA / mA L rms DC Peak t =10ms I - - 400 mA LPK P On-Resistance I =150mA R -7 16 L ON Off-State Leakage Current V =60V I -- 1 A L P LEAK Switching Speeds Turn-On t - 0.1 5 on I =5mA, V =10V ms F L Turn-Off t - 0.5 5 off Output Capacitance V =50V, f=1MHz C -25 - pF L OUT Input Characteristics Input Control Current to Activate I =150mA I -- 1 mA L F Input Control Current to Deactivate - - 0.05 - - mA Input Voltage Drop I =5mA V 0.9 1.2 1.4 V F F Reverse Input Current V =5V I - - 10 A R R Common Characteristics Input to Output Capacitance - C -3 - pF I/O 1 If both poles operate simultaneously, then the load current must be derated so as not to exceed the package power dissipation value. R03 2 www.ixysic.com