XBA170 Dual Single-Pole, Normally Open OptoMOS Relay INTEGRATED CIRCUITS DIVISION Parameter Rating Units Description Load Voltage 350 V XBA170 comprises two independent 350V, 100mA, Load Current 100 mA / mA rms DC 50 solid state relays: one single-pole, normally On-Resistance (max) 50 open (1-Form-A) relay and one single-pole, normally Input Control Current 5 mA closed (1-Form-B) relay. Featuring low on-resistance combined with enhanced Features peak load current handling capabilities, XBA170 3750V Input/Output Isolation is designed to provide an ideal solution where a rms Low Drive Power Requirements (TTL/CMOS complementary Form-A/Form-B relay pair is required. Compatible) No Moving Parts Approvals High Reliability UL Recognized Component: File E76270 Arc-Free With No Snubbing Circuits CSA Certified Component: Certificate 1175739 VDE Compatible EN/IEC 60950-1 Compliant FCC Compatible No EMI/RFI Generation Small 8-Pin Package Ordering Information Machine Insertable, Wave Solderable Part Description Surface Mount & Tape & Reel Version Available XBA170 8-Pin DIP (50/Tube) XBA170P 8-Pin Flatpack (50/Tube) Applications XBA170PTR 8-Pin Flatpack (1000/Reel) Telecommunications XBA170S 8-Pin Surface Mount (50/Tube) Telecom Switching XBA170STR 8-Pin Surface Mount (1000/Reel) Tip/Ring Circuits Modem Switching (Laptop, Notebook, Pocket Size) Hook Switch Pin Configuration Dial Pulsing Ground Start AC/DC Configuration Ringing Injection 1 8 + Control - Normally Closed Instrumentation Normally Closed Pole 2 7 Multiplexers Control - Normally Closed 3 6 Data Acquisition + Control - Normally Open Normally Open Pole Electronic Switching 4 5 Control - Normally Open I/O Subsystems Utility Meters (gas, oil, electric and water) Medical Equipment-Patient/Equipment Isolation Security Switching Characteristics Switching Characteristics Aerospace of Normally Open Devices of Normally Closed Devices Industrial Controls Form-A Form-B I I F F I LOAD 90% 90% 10% 10% I LOAD t t t t off on on off Pb e3 DS-XBA170-R04 1 www.ixysic.comXBA170 INTEGRATED CIRCUITS DIVISION Absolute Maximum Ratings 25C Absolute Maximum Ratings are stress ratings. Stresses in Parameter Ratings Units excess of these ratings can cause permanent damage to Blocking Voltage 350 V P the device. Functional operation of the device at conditions Reverse Input Voltage 5 V beyond those indicated in the operational sections of this Input Control Current 50 mA data sheet is not implied. 1A Peak (10ms) 1 Input Power Dissipation 150 mW 2 Total Power Dissipation 800 mW Isolation Voltage, Input to Output 3750 V rms Operational Temperature -40 to +85 C Storage Temperature -40 to +125 C 1 Derate linearly 1.33 mW / C 2 Derate linearly 6.67 mW / C Electrical Characteristics 25C Parameter Conditions Symbol Min Typ Max Units Output Characteristics Load Current AC/DC Configuration, Continuous - I - - 100 mA / mA L rms DC Peak t=10ms I - - 350 mA LPK P On-Resistance, AC/DC Configuration I =100mA R -33 50 L ON Off-State Leakage Current V =350V I -- 1 A L P LEAK Switching Speeds Turn-On t -- 5 on I =5mA, V =10V ms F L Turn-Off t -- 5 off Output Capacitance V =50V, f=1MHz C -25- pF L OUT Input Characteristics Input Control Current to Activate I =100mA I -- 2 mA L F Input Control Current to Deactivate - I 0.4 0.7 - mA F Input Voltage Drop I =5mA V 0.9 1.2 1.4 V F F Reverse Input Current V =5V I -- 10 A R R Common Characteristics Capacitance, Input to Output - C -3- pF I/O *NOTE: If both poles operate simultaneously, then the load current must be derated in order not to exceed the package power dissipation value. R04 2 www.ixysic.com