MAAPSS0071
DECT Power Amplifier
Rev. V3
1880 - 1930 MHz
Features
Functional Schematic
Ideal for DECT Applications
VCC1 N/C VCC2
Saturated Output Power: +26 dBm Typical
Power Gain: 26 dB Typical
Low Current: 400 mA at P
SAT
RF OUT/
GND
Ramp Power Control VCC3
Micro-Amp Shutdown
Operates from 1.5 V to 4.0 V
V configurable for either 1.7 V or 2.5 V RF OUT/
EN
RF IN
VCC3
Lead-Free 3 mm 12-Lead PQFN Package
100% Matte Tin Plating over Copper
Halogen-Free Green Mold Compound
RF OUT/
Ven1
RoHS* Compliant 260C Reflow Compatible VCC3
Description
Ven2, 3 N/C
N/C
The MAAPSS0071 is a three stage power amplifier
designed for Cordless Telephone applications. This
power amplifier is mounted in a standard outline,
Pin Configuration
lead-free 3 mm 12-lead PQFN plastic package. The
MAAPSS0071 features an integrated power enable
Pin No. Pin Name Description
control pin.
1 GND Ground
1
2 RF RF Input
IN
Ordering Information
3 V Power Enable
EN1
Part Number Package
4 V Power Enable
EN2,3
MAAPSS0071 Bulk Packaging
5 N/C No Connection
MAAPSS0071TR-3000 3000 piece reel
6 N/C No Connection
Sample Test Board
MAAPSS0071SMB
(Includes 5 Samples)
7 RF / V RF Output, 3rd Stage Supply
OUT CC3
1. Reference Application Note M513 for reel size information. 8 RF / V RF Output, 3rd Stage Supply
OUT CC3
9 RF / V RF Output, 3rd Stage Supply
OUT CC3
2,3
Absolute Maximum Ratings
10 V 2nd Stage Supply
CC2
Parameter Absolute Maximum
11 N/C No Connection
Input Power + 5 dBm
12 V 1st Stage Supply
CC1
Operating Supply Voltage +4.0 Volts
4
Pad GND RF & DC Ground
Operating Control Voltage +3.0 Volts
4. The exposed pad centered on the package bottom must be
Operating Temperature -20C to +85C
connected to RF and DC ground.
Channel Temperature +150C
Storage Temperature -40C to +150C
2. Exceeding any one or combination of these limits may cause
permanent damage to this device.
3. M/A-COM does not recommend sustained operation near
these survivability limits.
* Restrictions on Hazardous Substances, European Union Directive 2002/95/EC.
1
ADVANCED: Data Sheets contain information regarding a product M/A-COM Technology Solutions
North America Tel: 800.366.2266 / Fax: 978.366.2266
is considering for development. Performance is based on target specifications, simulated results,
Europe Tel: 44.1908.574.200 / Fax: 44.1908.574.300
and/or prototype measurements. Commitment to develop is not guaranteed.
Asia/Pacific Tel: 81.44.844.8296 / Fax: 81.44.844.8298
PRELIMINARY: Data Sheets contain information regarding a product M/A-COM Technology
Visit www.macomtech.com for additional data sheets and product information.
Solutions has under development. Performance is based on engineering tests. Specifications are
typical. Mechanical outline has been fixed. Engineering samples and/or test data may be available.
M/A-COM Technology Solutions Inc. and its affiliates reserve the right to make
Commitment to produce in volume is not guaranteed.
changes to the product(s) or information contained herein without notice. MAAPSS0071
DECT Power Amplifier
Rev. V3
1880 - 1930 MHz
Electrical Specifications:
Frequency = 1905 MHz, P = -2 to 2 dBm, V = 2.4 V, V = 2.5 V, T = 25 C, Z = 50
IN CC EN A 0
Parameter Test Conditions Units Min. Typ. Max
Input Return Loss dB 15
Output Power dBm 24 26 27
Power Flatness 2.0 < V < 3.0 V dB 3
CC
PAE % 45
Current mA 400 500
Current, Off V = 0 V A 3 10
EN
Pdiss P = 26.0 dBm W 0.5
OUT
V Low V 0 0.5
EN,
Control Pins V High V 2.0 2.5
EN,
Current mA 2.0 4.0
2f dBc -35
Harmonics
3f dBc -40
Forward Isolation V = 0 V dB 39
EN
Duty Cycle % 100
Ton: RF burst to NTP-1 S 3
Turn on/off time
Toff: NTP-1 to off S 2
+1.5V < V < +3.5 V, P = -2 to 2 dBm, VSWR < 6:1
CC IN
Stability All spurs < -60 dBc
-20C < T < +70C, RBW = 3 MHz max hold
C
Lead-Free 3 mm 12-Lead PQFN
Reference Application Note M538 for lead-free solder reflow recommendations.
Meets JEDEC moisture sensitivity level 1 requirements.
Operating the MAAPSS0071
The MAAPSS0071 can be damaged by electrostatic
discharge (ESD). Use proper ESD control
techniques when handling this device. To operate
the MAAPSS0071, turn on the V before V for
CC EN
power on and turn off V after V for shutdown.
CC EN
2
ADVANCED: Data Sheets contain information regarding a product M/A-COM Technology Solutions
North America Tel: 800.366.2266 / Fax: 978.366.2266
is considering for development. Performance is based on target specifications, simulated results,
Europe Tel: 44.1908.574.200 / Fax: 44.1908.574.300
and/or prototype measurements. Commitment to develop is not guaranteed.
Asia/Pacific Tel: 81.44.844.8296 / Fax: 81.44.844.8298
PRELIMINARY: Data Sheets contain information regarding a product M/A-COM Technology
Visit www.macomtech.com for additional data sheets and product information.
Solutions has under development. Performance is based on engineering tests. Specifications are
typical. Mechanical outline has been fixed. Engineering samples and/or test data may be available.
M/A-COM Technology Solutions Inc. and its affiliates reserve the right to make
Commitment to produce in volume is not guaranteed.
changes to the product(s) or information contained herein without notice.