GaN Amplifier 50 V, 300 W DC - 2.7 GHz MAGX-100027-300C0P Rev. V2 Features Suitable for Linear and Saturated Applications Pair of Isolated, Symmetric Amplifiers CW and Pulsed Operation: 300 W Output Power Internally Pre-Matched 260C Reflow Compatible 50 V Operation 100% RF Tested RoHS* Compliant Description Functional Schematic The MAGX-100027-300C0P is high power GaN on Si HEMT device optimized for DC - 2.7 GHz frequency operation. The device supports both CW and pulsed operation with peak output power levels RFIN/VG RFOUT/VD of 300 W (54.8 dBm) in a plastic package. The MAGX-100027-300C0P is ideally suited for a PAD multitude of applications including military radio communications, digital cellular infrastructure, RF energy, avionics, test instrumentation and RADAR. RFIN/VG RFOUT/VD Typical Performance: V = 50 V, I = 100 mA, T = 25C. One side DS DQ C Measured under pulsed load-pull at 2.5 dB Pin Configuration Compression, 100 s pulse width,1 ms period, 10% duty cycle 1 RF / V RF Input / Gate IN G1 1 2 2 Frequency Output Power Gain D 2 RF / V RF Output / Drain OUT D1 (GHz) (dBm) (dB) (%) 3 RF / V RF Input / Gate IN G2 0.9 53.5 20.0 71.1 4 RF / V RF Output / Drain OUT D2 1.4 53.3 17.6 74.8 3 2.0 53.5 15.0 64.3 5 Pad Ground / Source 2.5 53.5 13.5 64.8 3. The exposed pad centered on the package bottom must be connected to RF, DC and thermal ground. 2.7 53.4 13.5 65.3 1. Load impedance tuned for maximum output power. 2. Load impedance tuned for maximum drain efficiency. Ordering Information Part Number Package MAGX-100027-300C0P Bulk quantity MAGX-100027-300CTP Tape and Reel MAGX-1A0027-300C0P Sample board * Restrictions on Hazardous Substances, compliant to current RoHS EU directive. 11 1 MACOM Technology Solutions Inc. (MACOM) and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice. Visit www.macom.com for additional data sheets and product information. For further information and support please visit: GaN Amplifier 50 V, 300 W DC - 2.7 GHz MAGX-100027-300C0P Rev. V2 RF Electrical Characteristics: T = 25C, V = 50 V, I = 200 mA C DS DQ Note: Performance in MACOM Evaluation Test Fixture, 50 system Parameter Test Conditions Symbol Min. Typ. Max. Units 4 Small Signal Gain Pulsed , 2 GHz G - 16.3 - dB SS 4 Power Gain Pulsed , 2 GHz, 2.5 dB Gain Compression G - 14.0 - dBm SAT 4 Saturated Drain Efficiency Pulsed , 2 GHz, 2.5 dB Gain Compression - 57.5 - % SAT 4 Saturated Output Power Pulsed , 2 GHz, 2.5 dB Gain Compression P - 55.5 - dBm SAT 4 Pulsed , 2 GHz G - 0.02 - Gain Variation (-25C to +85C) dB/C 4 Power Variation (-25C to +85C) Pulsed , 2 GHz P2.5dB - 0.01 - dB/C 4 Gain Pulsed , 2 GHz, P = 41.2 dBm G - 14.5 - dB IN P 4 Drain Efficiency Pulsed , 2.0 GHz, P = 41.2 dBm - 57.5 - % IN Ruggedness: Output Mismatch All phase angles VSWR = 10:1, No Damage RF Electrical Specifications: T = 25C, V = 50 V, I = 200 mA A DS DQ Note: Performance in MACOM Production Test Fixture, 50 system Parameter Test Conditions Symbol Min. Typ. Max. Units 4 Power Gain Pulsed , 2 GHz, 2.5 dB Gain Compression G 13 14 - dB SAT 4 Saturated Drain Efficiency Pulsed , 2 GHz, 2.5 dB Gain Compression 52 57.5 - % SAT 4 Saturated Output Power Pulsed , 2 GHz, 2.5 dB Gain Compression P 54 55.4 - dBm SAT 4 Gain Pulsed , 2 GHz, P = 41.2 dBm G 13 14.2 - dB IN P 4 Drain Efficiency Pulsed , 2 GHz, P = 41.2 dBm 52 57.5 - dB IN 4. Pulse details: 100 s pulse width, 1 ms period, 10% Duty Cycle. DC Electrical Characteristics (Per Each Side of Symmetric Device) T = 25C A Parameter Test Conditions Symbol Min. Typ. Max. Units Drain-Source Leakage Current V = -8 V, V = 130 V I - - 29.2 mA GS DS DLK Gate-Source Leakage Current V = -8 V, V = 0 V I - - 29.2 mA GS DS GLK Gate Threshold Voltage V = 50 V, I = 29.2 mA V -2.6 -2.15 -1.6 V DS D T Gate Quiescent Voltage V = 50 V, I = 150 mA V -2.4 -2.05 -1.4 V DS D GSQ On Resistance V = 2 V, I = 200 mA R - 0.16 - GS D ON Maximum Drain Current V = 7 V pulsed, pulse width 300 s I - 17.0 - A DS D, MAX 22 2 MACOM Technology Solutions Inc. (MACOM) and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice. Visit www.macom.com for additional data sheets and product information. For further information and support please visit: