45W Single Output Industrial DIN Rail Power Supply DR-45 series 6 - 5 0 16 ( 7 - 8 1 0 1 0 0 ( 1 0 ( 0 9: 8* 1, 5 <2 . 4 0 /9 & = * 6 > & ( . % & Bauart gepruft Sicherheit egelma ge od os be wac g www.tuv.com ID 2000000000 SPECIFICATION MODEL DR-4505 DR-4512 DR-4515 DR-4524 DC VOLTAGE 5V 12V 15V 24V RATED CURRENT 5A 3.5A 2.8A 2A CURRENT RANGE 0 ~ 5A 0 ~3. 5A 0 ~ 2.8A 0 ~ 2A RATED POWER 25W 42W 42W 48W RIPPLE & NOISE (max.) Note.2 100mVp-p 200mVp-p 240mVp-p 480mVp-p OUTPUT VOLTAGE ADJ. RANGE 4.75 ~ 5.5V 10.8 ~ 13.2V 13.5 ~ 16.5V 21.6 ~ 26.4V VOLTAGE TOLERANCE Note.3 2.0% 1.0% 1.0% 1.0% LINE REGULATION 1.0% 1.0% 1.0% 1.0% LOAD REGULATION 1.0% 1.0% 1.0% 1.0% SETUP, RISE TIME 800ms, 60ms/230VAC at full load HOLD UP TIME (Typ.) 60ms/230VAC at full load VOLTAGE RANGE 85 ~ 264VAC 120 ~ 370VDC FREQUENCY RANGE 47 ~ 63Hz EFFICIENCY (Typ.) 72% 77% 77% 80% INPUT AC CURRENT (Typ.) 1.5A/115VAC 0.75A/230VAC INRUSH CURRENT (Typ.) COLD START 28A/115VAC 56A/230VAC LEAKAGE CURRENT <1mA / 240VAC 105 ~ 150% rated output power OVERLOAD Protection type : Constant current limiting, recovers automatically after fault condition is removed 5.75 ~ 6.75V 13.8 ~ 16.2V 17.25 ~ 20.25V 27.6 ~ 32.4V PROTECTION OVER VOLTAGE Protection type : Shut off o/p voltage, clamping by zener diode Tj 135 typically (U1) detect on heat sink of power transistor OVER TEMPERATURE Protection type : Shut down o/p voltage, re-power on to recover -10 ~ +50 (Refer toDerating Curv) WORKING TEMP. 20 ~ 90% RH non-condensing WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY -20 ~ +85, 10 ~ 95% RH TEMP. COEFFICIENT 0.03%/ (0 ~ 50) 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes Mounting: Compliance to IEC60068-2-6 VIBRATION UL508, TUV EN60950-1, EAC TP TC 004 approved SAFETY STANDARDS WITHSTAND VOLTAGE I/P-O/P:3KVAC I/P-FG:2.0KVAC O/P-FG:0.5KVAC SAFETY & ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH EMC (Note 4) EMC EMISSION Compliance to EN55011,EN55032 (CISPR32), EN61000-3-2,-3, EAC TP TC 020 Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, EN61000-6-2 (EN50082-2), heavy industry level, criteria A, EAC TP TC 020 EMC IMMUNITY MTBF 364.6K hrs min. MIL-HDBK-217F (25) OTHERS DIMENSION 93*78*67mm (L*W*H) 0.31Kg 48pcs/17.5Kg/1.3CUFT PACKING NOTE % & ( ) & *& & +, - ( ( + & & & * / 0 ( 1 & 1 & ( ( 23 4 File Name:DR-45-SPEC 2018-01-1235 45W Single Output Industrial DIN Rail Power Supply DR-45 series Mechanical Specification Case No. 918A Unit:mm 46.5 46.5 9 8 7 6 5 4 3 Install DIN rail TS35/7.5 or TS35/15 2 1 Terminal Pin No. Assignment 77 93 Pin No. Assignment Pin No. Assignment 1 AC/L 6,7 DC OUTPUT+V 2 AC/N 8 LED 3 FG 9 +V ADJ. 4,5 DC OUTPUT -V Block Diagram fosc : 100KHz RECTIFIERS POWER RECTIFIERS +V EMI I/P & SWITCH- & FILTER -V FILTER ING FILTER PWM CONTROL DETECTION FG CIRCUIT Derating Curve Static Characteristics (24V) Ta=25 32 350 100 28 300 80 24 250 60 20 200 16 150 40 12 100 20 8 50 -10 0102030405060(VERTICAL) 70 80 100 120 140 160 180 200 220 240 260 AMBIENT TEMPERATURE () INPUT VOLTAGE (V) 60Hz File Name:DR-45-SPEC 2018-01-12 LOAD (%) 78 67 OUTPUT VOLTAGE (V) 7.5 8.5 29 OUTPUT RIPPLE (mVp-p)