40W Single Output with Battery Charger (UPS Function) DRC-40 series Bauar t gepruft Sicherheit egelma ge od o s be wac g w w w .t u v.c o m LPS ID 2000000000 UL62368-1 BS EN/EN62368-1 IEC62368-1 TPTC004 File Name:DRC-40-SPEC 2 0 2 1 - 0 6 - 0 140W Single Output with Battery Charger (UPS Function) DRC-40 series SPECIFICATION MODEL DRC-40A DRC-40B OUTPUT NUMBER CH1 CH2 CH1 CH2 DC VOLTAGE 13.8V 13.8V 27.6V 27.6V RATED CURRENT 1.9A 1A 0.95A 0.5A CURRENT RANGE 0 ~ 2.9A -------- 0 ~ 1.45A -------- RATED POWER 40.02W 40.02W RIPPLE & NOISE (max.) Note.2 120mVp-p -------- 200mVp-p -------- OUTPUT VOLTAGE ADJ. RANGE CH1:12 ~ 15V CH1:24 ~ 30V VOLTAGE TOLERANCE Note.3 1.0% -------- 1.0% -------- LINE REGULATION 0.5% -------- 0.5% -------- LOAD REGULATION 0.5% -------- 0.5% -------- SETUP, RISE TIME Note.4 400ms, 50ms/230VAC 800ms, 50ms/115VAC at full load HOLD UP TIME (Typ.) 50ms/230VAC 10ms/115VAC at full load VOLTAGE RANGE 90 ~ 264VAC 127 ~ 370VDC DC input operation possible by connecting AC/L(+), AC/N(-) FREQUENCY RANGE 47 ~ 63Hz INPUT EFFICIENCY (Typ.) 86% 87% 0.8A/115VAC 0.6A/230VAC AC CURRENT (Typ.) INRUSH CURRENT (Typ.) COLD START 30A/115VAC 60A/230VAC 105 ~ 150% rated output power OVERLOAD Protection type : Hiccup mode, recovers automatically after fault condition is removed CH1:14.49 ~ 18.63V CH1:28.98 ~ 37.26V PROTECTION OVER VOLTAGE Protection type : Shut down o/p voltage, re-power on to recover 100.5V 201V BATTERY CUT OFF Open collector output, CONTACT : AC OK CUT OFF : AC Fail max. rating : 50V/30mA AC OK FUNCTION Open collector output, CUT OFF : Battery CONTACT : Battery Low max. rating : 50V/30mA BATTERY LOW Battery low voltage : < 11V Battery low voltage : < 22V -30 ~ +70 (Refer toDerating Curv) WORKING TEMP. 20 ~ 90% RH non-condensing WORKING HUMIDITY STORAGE TEMP., HUMIDITY -40 ~ +85, 10 ~ 95% RH ENVIRONMENT TEMP. COEFFICIENT 0.03%/ (0 ~ 55) on CH1 output VIBRATION 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes UL62368-1, TUV BS EN/EN62368-1, EAC TP TC 004, AS/NZS 60950.1 approved SAFETY STANDARDS WITHSTAND VOLTAGE I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC SAFETY & EMC ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH (Note 5) EMC EMISSION Compliance to BS EN/EN55032 (CISPR32) Class B, BS EN/EN61000-3-2,-3, EAC TP TC 020 Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN55024, BS EN/EN61204-3, light industry level, EMC IMMUNITY criteria A, EAC TP TC 020 MTBF 536.6K hrs min. MIL-HDBK-217F (25) OTHERS DIMENSION 40*90*100mm (W*H*D) 0.3Kg 42pcs/13.6Kg/0.82CUFT PACKING NOTE (as available on