60W Single Output with Battery Charger (UPS Function) DRC-60 series Bauar t gep r u f t S i c h e r h e i t e g e l m a ge o d o s b e w a c g w w w .t u v.c o m LPS ID 2000000000 UL62368-1 BS EN/EN62368-1 IEC62368-1 TPTC004 File Name:DRC-60-SPEC 2 0 2 1 - 0 6 - 0 160W Single Output with Battery Charger (UPS Function) DRC-60 series SPECIFICATION MODEL DRC-60A DRC-60B OUTPUT NUMBER CH1 CH2 CH1 CH2 DC VOLTAGE 13.8V 13.8V 27.6V 27.6V RATED CURRENT 2.8A 1.5A 1.4A 0.75A CURRENT RANGE 0 ~ 4.3A -------- 0 ~ 2.15A -------- RATED POWER 59.34W 59.34W RIPPLE & NOISE (max.) Note.2 120mVp-p -------- 200mVp-p -------- OUTPUT VOLTAGE ADJ. RANGE CH1:12 ~ 15V CH1:24 ~ 30V VOLTAGE TOLERANCE Note.3 1.0% -------- 1.0% -------- LINE REGULATION 0.5% -------- 0.5% -------- LOAD REGULATION 0.5% -------- 0.5% -------- SETUP, RISE TIME Note.4 400ms, 50ms/230VAC 800ms, 50ms/115VAC at full load HOLD UP TIME (Typ.) 50ms/230VAC 10ms/115VAC at full load VOLTAGE RANGE 90 ~ 264VAC 127 ~ 370VDC DC input operation possible by connecting AC/L(+), AC/N(-) FREQUENCY RANGE 47 ~ 63Hz INPUT EFFICIENCY (Typ.) 86% 88% 1.3A/115VAC 0.8A/230VAC AC CURRENT (Typ.) INRUSH CURRENT (Typ.) COLD START 30A/115VAC 60A/230VAC 105 ~ 150% rated output power OVERLOAD Protection type : Hiccup mode, recovers automatically after fault condition is removed CH1:14.49 ~ 18.63V CH1:28.98 ~ 37.26V PROTECTION OVER VOLTAGE Protection type : Shut down o/p voltage, re-power on to recover 100.5V 201V BATTERY CUT OFF AC OK Relay contact output, ON : AC OK OFF : AC Fail max. rating : 30V/1A Relay contact output, OFF : Battery OK ON : Battery Low max. rating : 30V/1A FUNCTION BATTERY LOW Battery low voltage : < 11V Battery low voltage : < 22V -30 ~ +70 (Refer toDerating Curv) WORKING TEMP. 20 ~ 90% RH non-condensing WORKING HUMIDITY STORAGE TEMP., HUMIDITY -40 ~ +85, 10 ~ 95% RH ENVIRONMENT TEMP. COEFFICIENT 0.03%/ (0 ~ 50) on CH1 output VIBRATION 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes SAFETY STANDARDS UL62368-1, TUV BS EN/EN62368-1, EAC TP TC 004, AS/NZS 60950.1 approved WITHSTAND VOLTAGE I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC SAFETY & EMC ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH (Note 5) EMC EMISSION Compliance to BS EN/EN55032 (CISPR32) Class B, BS EN/EN61000-3-2,-3, EAC TP TC 020 Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN55024, BS EN/EN61204-3, light industry level, EMC IMMUNITY criteria A, EAC TP TC 020 MTBF 504.1K hrs min. MIL-HDBK-217F (25) OTHERS DIMENSION 40*90*100mm (W*H*D) PACKING 0.3Kg 42pcs/13.6Kg/0.82CUFT NOTE