960W Three Phase Industrial DIN RAIL Power Supply DRT-960 series : % & ( & ( ( & ( ) * + , - ( - ./0 % &12 34 5* 6 ) , ( 708 8 9*70 59 9, )) ( - Bauart gepruft Sicherheit egelma ge od os be wac g www.tuv.com ID 2000000000 SPECIFICATION MODEL DRT-960-24 DRT-960-48 DC VOLTAGE 24V 48V RATED CURRENT 40A 20A CURRENT RANGE 0 ~ 40A 0 ~ 20A RATED POWER 960W 960W RIPPLE & NOISE (max.) Note.2 80mVp-p 80mVp-p OUTPUT VOLTAGE ADJ. RANGE 24 ~ 28V 48 ~ 55V VOLTAGE TOLERANCE Note.3 1.0% 1.0% LINE REGULATION 0.5% 0.5% LOAD REGULATION 0.5% 0.5% SETUP, RISE TIME 200ms, 60ms/400VAC 200ms, 60ms/500VAC at full load HOLD UP TIME (Typ.) 14ms/400VAC 30ms/500VAC at full load VOLTAGE RANGE Three-Phase 340 ~ 550VAC (Dual phase operation possible in connecting L1,L3,FG Note.5) FREQUENCY RANGE 47 ~ 63Hz EFFICIENCY (Typ.) 91% 92% INPUT AC CURRENT (Typ.) 2A/400VAC 1.6A/500VAC INRUSH CURRENT (max.) COLD START 50A LEAKAGE CURRENT <3.5mA / 530VAC 105 ~ 125% rated output power OVERLOAD Protection type : Constant current limiting, unit will shut down o/p voltage after 3 sec. , re-power on to recover 30 ~ 36V 59 ~ 66V PROTECTION OVER VOLTAGE Protection type : Shut down o/p voltage, re-power on to recover OVER TEMPERATURE Shut down o/p voltage, recovers automatically after temperature goes down -20 ~ +60 (Refer toDerating Curv) WORKING TEMP. 20 ~ 90% RH non-condensing WORKING HUMIDITY STORAGE TEMP., HUMIDITY -40 ~ +85, 10 ~ 95% RH non-condensing ENVIRONMENT TEMP. COEFFICIENT 0.03%/ (0 ~ 50) Component:10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes Mounting: Compliance to IEC60068-2-6 VIBRATION SAFETY STANDARDS UL508, UL60950-1, TUV EN60950-1, EAC TP TC 004 approved WITHSTAND VOLTAGE I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC SAFETY & ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25/ 70% RH EMC (Note 4) EMC EMISSION Compliance to EN55011 (CISPR11), EN55032 (CISPR32), EN61204-3 Class B, EN61000-3-2,-3, EAC TP TC 020 EMC IMMUNITY Compliance to EN61000-4-2,3,4,5,6,8,11, EN61204-3, EN61000-6-2 (EN50082-2), heavy industry level, criteria A, EAC TP TC 020 MTBF 122.5K hrs min. MIL-HDBK-217F (25) OTHERS DIMENSION 276*125.2*100mm (W*H*D) 3.3Kg 4pcs/14.2Kg/1.14CUFT PACKING 2 ) 0 ) ) 9 )- ) 2 NOTE 92 < = ) 9 > - - 9 ) 2 = 1 2 2 2 2 ) - 6 ) 2 6 ) ) - ) ) 7> ( 2 2 . * 4 4 :A, 2 ( 2 82 )- ) 2 & ) ) & ) ) 9 )*8 ,2 File Name:DRT-960-SPEC 2018-01-15960W Three Phase Industrial DIN RAIL Power Supply DRT-960 series Mechanical Specification Case No.934 Unit:mm 100 276 TB1 TB2 ALARM 43 2 1 625 4 31 LED +V ADJ Terminal Pin No. Assignment (TB1) Pin No. Assignment 1 AC/L1 2 AC/L2 35 3 AC/L3 4 FG ADMISSIBLE DIN-RAIL: TS35/7.5 OR TS35/15 Terminal Pin No. Assignment (TB2) Pin No. Assignment 1,2,3 DC OUTPUT +V 4,5,6 DC OUTPUT -V Block Diagram fosc : 55KHz RECTIFIERS RECTIFIERS POWER EMI +V I/P & & FILTER SWITCHING -V FILTER FILTER DETECTION O.T.P. CIRCUIT FG CURRENT PHASE-SHIFT LIMIT PWM CONTROL O.V.P. Derating Curve Static Characteristics 100 100 Three phase operation 90 80 80 Dual phase operation 70 60 50 60 40 50 20 40 (VERTICAL) -20 010203040455060 70 340 355 380 385 400 415 430 460 475 490 505 520 550 AMBIENT TEMPERATURE () INPUT VOLTAGE (VAC) 60Hz File Name:DRT-960-SPEC 2018-01-15 LOAD (%) LOAD (%) 125.2