190W Dual Output with PFC Function HDP-190 % & ( )* +,- ( SPECIFICATION MODEL HDP-190 OUTPUT NUMBER V1 V2 DC VOLTAGE +3.8V +2.8V RATED CURRENT 33A 20A CURRENT RANGE (max.) 0 ~ 40A 0 ~ 22A RATED POWER 181.4W (typ.) 192W (max.) 192W continue. V1 total power output shall not exceed 160W (max. 40A) V2 total power output shall not exceed 66W (max. 22A) OUTPUT POWER (max.) (The V1 & V2 combine total power output shall not exceed 192W) OUTPUT RIPPLE & NOISE (max.) Note.2 100mVp-p 100mVp-p VOLTAGE ADJ. RANGE Note.6 3.6 ~ 4V 2.5 ~ 3V VOLTAGE TOLERANCE Note.3 2.0% 2.0% LINE REGULATION 0.5% 0.5% LOAD REGULATION 2.0% 2.0% SETUP, RISE TIME 1000ms, 50ms/230VAC 2500ms, 50ms/115VAC at full load HOLD UP TIME (Typ.) 16ms/230VAC 16ms/115VAC at full load VOLTAGE RANGE Note.5 90 ~ 264VAC 127 ~ 370VDC FREQUENCY RANGE 47 ~ 63Hz POWER FACTOR (Typ.) PF0.94/230VAC PF 0.98/115VAC at full load INPUT EFFICIENCY (Typ.) 86% AC CURRENT (Typ.) 2.7A/115VAC 1.1A/230VAC INRUSH CURRENT (Typ.) 30A/115VAC 45A/230VAC LEAKAGE CURRENT <0.7mA / 240VAC V1+V2: 105 ~ 150% max. output power or V2: 125 ~ 170% rated current OVERLOAD Protection type: Hiccup mode, recovers automatically after fault condition is removed V1: 4.37 ~ 5.13V V2: 3.22 ~ 3.78V PROTECTION OVER VOLTAGE Protection type : Shut down o/p voltage, re-power on to recover OVER TEMPERATURE Shut down o/p voltage, re-power on to recovery WORKING TEMP. -30 ~ +70 (Refer toDerating Curv) 20 ~ 90% RH non-condensing WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY -40 ~ +85, 10 ~ 95% RH TEMP. COEFFICIENT 0.03%/ (0 ~ 50) VIBRATION 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes SAFETY STANDARDS UL60950-1, TUV EN60950-1, CCC GB4943.1 approved WITHSTAND VOLTAGE I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC SAFETY & ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25/ 70% RH EMC (Note 4) EMC EMISSION Compliance to EN55022 (CISPR22), GB9254, class B, EN61000-3-2,-3, GB17625.1 EMC IMMUNITY Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, EN61000-6-2, heavy industry level, criteria A MTBF 111.3K hrs min. MIL-HDBK-217F (25) OTHERS DIMENSION 215*115*36mm (L*W*H) PACKING 0.95Kg 15pcs/15.3Kg/0.7CUFT &. 0 1(2* 3 14 % . NOTE 1. 5 6 127 8 % % &19 2.& 6 : . (. 0 3 . :. 0 % < . 0 < % ,7 . 4. - % . = . . % *& *1 % &.2*>*& *1&.2* . File Name:HDP-190-SPEC 2015-02-28190W Dual Output with PFC Function HDP-190 Mechanical Specification Case No.206A Unit:mm 215 204.5 97.5 32.5 150 24 15.85 SVR1 Terminal Pin No. Assignment : 11 Pin No. Assignment Pin No. Assignment LED 10 1 AC/L 4,5 V2(+2.8V) 9 2 AC/N 6,7 V1(+3.8V) 8 3 FG 8,9,10,11 COM 7 4-M4 L=5mm SVR1: V1(+3.8V)ADJ. 6 SVR2 SVR2: V2(+2.8V)ADJ. 5 4 3 2 1 5-M3 L=3mm 15 215 150 32.5 16max. 4-M4 L=5mm Block Diagram PFC fosc : 65KHz PWM fosc : 80KHz ACTIVE RECTIFIERS RECTIFIERS EMI +V1 INRUSH POWER & & I/P FILTER CURRENT SWITCHING COM PFC FILTER LIMITING POWER O.T.P. O.L.P. & DETECTION SWITCHING CIRCUIT FG +V2 PFC PWM O.V.P. O.L.P. CONTROL CONTROL PWM DETECTION CONTROL CIRCUIT O.V.P. Derating Curve Output Derating VS Input Voltage 100 100 90 80 80 70 60 50 60 40 50 20 40 -30 010203040506070 (HORIZONTAL) 90 95 100 115 130 145 165 185 205 225 245 264 AMBIENT TEMPERATURE () INPUT VOLTAGE (V) 60Hz File Name:HDP-190-SPEC 2015-02-28 135 LOAD (%) 3.5 9.5 8.3 16 LOAD(%) 12.5 10 95 36 32.5 50 34.4 44.75 108 115