85 ~ 100W Ultra Slim Step Shape DIN Rail HDR-100 series Bauar t gep ruft Sicherheit egel ma ge od o s b e w a c g www. tuv. com ID 2000000000 UL60950-1 (Blank type only) UL508 EN61558 IEC60950-1 Features Ultra slim design with 70mm( ass LPS (Limited power source) for Blank type / ooling by free air convection (working temperature:-30~+70C) DIN rail TS-35/7.5 or 15 mountable ED indicator for power on File Name:HDR-100-SPEC 2017- 05-0385 ~ 100W Ultra Slim Step Shape DIN Rail HDR-100 series SPECIFICATION HDR-100-15N HDR-100-24N HDR-100-48N HDR-100-12 HDR-100-12N HDR-100-15 HDR-100-24 HDR-100-48 MODEL 12V 15V 24V 48V DC VOLTAGE RATED CURRENT 7.1A 7.5A 6.13A 6.5A 3.83A 4.2A 1.92A 2.1A CURRENT RANGE 0 ~ 7.1A 0 ~ 7.5A 0 ~ 6.13A 0 ~ 6.5A 0 ~ 3.83A 0 ~ 4.2A 0 ~1.92A 0 ~ 2.1A RATED POWER 85.2W 90W 92W 97.5W 92W 100.8W 92.2W 100.8W RIPPLE & NOISE (max.) Note.2 120mVp-p 120mVp-p 150mVp-p 240mVp-p OUTPUT Pass LPS 12 ~ 13V 15 ~ 17V 24 ~ 25.5V 48 ~ 48.7V VOLTAGE ADJ. RANGE Non LPS 12~ 13.8V 21.6 ~ 29V 13.5 ~ 18V 43.2 ~ 55.2V 2.0% VOLTAGE TOLERANCE Note.3 1.0% 1.0% 1.0% 1.0% 1.0% 1.0% 1.0% LINE REGULATION 1.0% 1.0% 1.0% 1.0% LOAD REGULATION SETUP, RISE TIME 500ms, 60ms/230VAC 500ms, 60ms/115VAC at full load HOLD UP TIME (Typ.) 30ms/230VAC 12ms/115VAC at full load VOLTAGE RANGE 85 ~ 264VAC (277VAC operational ) 120 ~ 370VDC (390VDC operational ) FREQUENCY RANGE 47 ~ 63Hz INPUT EFFICIENCY (Typ.) 88% 89% 90% 90% AC CURRENT (Typ.) 3A/115VAC 1.6A/230VAC INRUSH CURRENT (Typ.) COLD START 35A/115VAC 70A/230VAC HDR-100 : 102 ~ 110% rated output power HDR-100-xxN : 105 ~ 150% rated output power OVERLOAD Note.4 Protection type : Constant current limiting, recovers automatically after fault condition is removed PROTECTION 14.2 ~ 16.2V 18.8 ~ 22.5V 30 ~ 36V 56.5 ~ 64.8V OVER VOLTAGE Protection type : Shut down o/p voltage, re-power on to recover -30 ~ +70 (Refer toDerating Curv) WORKING TEMP. 20 ~ 90% RH non-condensing WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY -40 ~ +85 , 10 ~ 95% RH non-condensing 0.03%/ (0 ~ 50 ) RH non-condensing TEMP. COEFFICIENT VIBRATION 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes Mounting: Compliance to IEC60068-2-6 OPERATING ALTITUDE 2000 meters SAFETY STANDARDS UL60950-1, UL508, TUV EN61558-2-16, IEC60950-1 approved Design refer to EN50178,TUV EN60950-1 WITHSTAND VOLTAGE I/P-O/P:3KVAC ISOLATION RESISTANCE I/P-O/P:100M Ohms / 500VDC / 25 / 70% RH Standard Test Level / Note Parameter Conducted EN55032(CISPR32) Class B EMC EMISSION Radiated EN55032(CISPR32) Class B Harmonic Current (Note 5) EN61000-3-2 Class A SAFETY & Voltage Flicker EN61000-3-3 ------- EMC EN55024, EN61000-6-2, EN61204-3 (Note 6) Parameter Standard Test Level /Note Level 3, 8KV air Level 2, 4KV contact, criteria A ESD EN61000-4-2 Radiated Susceptibility EN61000-4-3 Level 3, criteria A EN61000-4-4 Level 3, criteria A EFT/Burest EMC IMMUNITY Surge Level 4,2KV/L-N, criteria A EN61000-4-5 Level 3, criteria A Conducted EN61000-4-6 Magnetic Field EN61000-4-8 Level 4, criteria A 95% dip 0 .5 periods, 30% dip 25 periods, EN61000-4-11 Voltage Dips and interruptions 95% interruptions 250 periods MTBF 856.5K hrs min. MIL-HDBK-217F (25 ) OTHERS DIMENSION 70*90*54.5mm (W*H*D) PACKING 0.27Kg 48pcs/14Kg/1.10CUFT NOTE File Name:HDR-100-SPEC 2017- 05-03