60W Ultra Slim Step Shape DIN Rail HDR-60 series Bauar t gep ruft Sicherheit egel ma ge od o s b e w a c g www. tuv. com ID 2000000000 UL60950-1 UL508 EN61558 IEC60950-1 Ultra slim design with 52.5mm( ass LPS (Limited power source) / ooling by free air convection (working temperature:-30~+70C) DIN rail TS-35/7.5 or 15 mountable ED indicator for power on File Name:HDR-60-SPEC 2016-10-2860W Ultra Slim Step Shape DIN Rail HDR-60 series SPECIFICATION MODEL HDR-60-5 HDR-60-12 HDR-60-15 HDR-60-24 HDR-60-48 DC VOLTAGE 5V 12V 15V 24V 48V RATED CURRENT 6.5A 4.5A 4A 2.5A 1.25A CURRENT RANGE 0 ~ 6.5A 0 ~ 4.5A 0 ~ 4A 0 ~ 2.5A 0 ~ 1.25A 32.5W RATED POWER 54W 60W 60W 60W RIPPLE & NOISE (max.) Note.2 80mVp-p 120mVp-p 120mVp-p 150mVp-p 240mVp-p OUTPUT VOLTAGE ADJ. RANGE 5.0 ~ 5.5V 10.8 ~ 13.8V 13.5 ~ 18V 21.6 ~ 29V 43.2 ~ 55.2V VOLTAGE TOLERANCE Note.3 2.0% 1.0% 1.0% 1.0% 1.0% LINE REGULATION 1.0% 1.0% 1.0% 1.0% 1.0% LOAD REGULATION 1.0% 1.0% 1.0% 1.0% 1.0% SETUP, RISE TIME 500ms, 50ms/230VAC 500ms, 50ms/115VAC at full load HOLD UP TIME (Typ.) 30ms/230VAC 12ms/115VAC at full load VOLTAGE RANGE 85 ~ 264VAC (277VAC available ) 120 ~ 370VDC (390VDC available ) FREQUENCY RANGE 47 ~ 63Hz INPUT EFFICIENCY (Typ.) 85% 88% 89% 90% 91% AC CURRENT (Typ.) 1.2A/115VAC 0.8A/230VAC INRUSH CURRENT (Typ.) COLD START 30A/115VAC 60A/230VAC 105 ~ 160% rated output power OVERLOAD Note.4 Protection type : Constant current limiting, recovers automatically after fault condition is removed PROTECTION 5.75 ~ 6.75V 14.2 ~ 16.2V 18.8 ~ 22.5V 30 ~ 36V 56.5 ~ 64.8V OVER VOLTAGE Protection type : Shut down o/p voltage, re-power on to recover WORKING TEMP. -30 ~ +70 (Refer toDerating Curv) 20 ~ 90% RH non-condensing WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY -40 ~ +85 , 10 ~ 95% RH non-condensing 0.03%/ (0 ~ 50 ) RH non-condensing TEMP. COEFFICIENT VIBRATION 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes Mounting: Compliance to IEC60068-2-6 OPERATING ALTITUDE 2000 meters SAFETY STANDARDS UL60950-1, UL508, TUV EN61558-2-16, IEC60950-1 approved Design refer to EN50178,TUV EN60950-1 WITHSTAND VOLTAGE I/P-O/P:3KVAC SAFETY & ISOLATION RESISTANCE I/P-O/P:100M Ohms / 500VDC / 25 / 70% RH EMC (Note 5) Parameter Standard Test Level / Note Conducted EN55032(CISPR32) Class B EMC EMISSION Radiated EN55032(CISPR32) Class B Harmonic Current EN61000-3-2 Class A Voltage Flicker ------- EN61000-3-3 EN55024, EN55035, EN61000-6-2, EN61204-3 Parameter Standard Test Level /Note ESD EN61000-4-2 Level 3, 8KV air Level 2, 4KV contact, criteria A EN61000-4-3 Level 3, criteria A Radiated Susceptibility Level 3, criteria A EFT/Burest EN61000-4-4 EMC IMMUNITY Surge Level 4,2KV/L-N, criteria A EN61000-4-5 Conducted EN61000-4-6 Level 3, criteria A EN61000-4-8 Level 4, criteria A Magnetic Field 95% dip 0 .5 periods, 30% dip 25 periods, EN61000-4-11 Voltage Dips and interruptions 95% interruptions 250 periods MTBF 927.6K hrs min. MIL-HDBK-217F (25 ) OTHERS DIMENSION 52.5*90*54.5mm (W*H*D) 190g 60pcs/12.4Kg/0.97CUFT PACKING NOTE File Name:HDR-60-SPEC 2016-10-28