100W Single Output with PFC Function HRP-100 series Users Manual % % & % ( ) * + , - .(( ( / / - ( 0 1 , - Bauart gepruft Sicherheit egelma ge od os be wac g www.tuv.com ID 2000000000 SPECIFICATION UL62368-1 BS EN/EN62368-1 TPTC004 IEC62368-1 MODEL HRP-100-3.3 HRP-100-5 HRP-100-7.5 HRP-100-12 HRP-100-15 HRP-100-24 HRP-100-36 HRP-100-48 DC VOLTAGE 3.3V 5V 7.5V 12V 15V 24V 36V 48V RATED CURRENT 20A 17A 13.5A 8.5A 7A 4.5A 2.9A 2.2A CURRENT RANGE 0 ~ 20A 0 ~ 17A 0 ~ 13.5A 0 ~ 8.5A 0 ~ 7A 0 ~ 4.5A 0 ~ 2.9A 0 ~ 2.2A RATED POWER 66W 85W 101.3W 102W 105W 108W 104.4W 105.6W RIPPLE & NOISE (max.) Note.2 80mVp-p 80mVp-p 100mVp-p 120mVp-p 150mVp-p 150mVp-p 200mVp-p 240mVp-p OUTPUT VOLTAGE ADJ. RANGE 3.1 ~ 3.8V 4.75 ~ 5.8V 7.1 ~ 9V 11.4 ~ 13.8V 14.25 ~ 18V 22.8 ~ 28.8V 34.2 ~ 39.6V 45.6 ~ 55.2V VOLTAGE TOLERANCE Note.3 +2.5,-3.5% 2.5% 2.5% 1.5% 1.5% 1.5% 1.5% 1.5% LINE REGULATION 0.5% 0.5% 0.5% 0.3% 0.3% 0.2% 0.2% 0.2% LOAD REGULATION 2.0% 2.0% 1.5% 0.8% 0.8% 0.5% 0.5% 0.5% SETUP, RISE TIME 2500ms, 100ms/230VAC 2500ms, 100ms/115VAC at full load HOLD UP TIME (Typ.) 50ms/230VAC 20ms/115VAC at full load VOLTAGE RANGE Note.5 85 ~ 264VAC 120 ~ 370VDC FREQUENCY RANGE 47 ~ 63Hz POWER FACTOR (Typ.) PF>0.95/230VAC PF>0.98/115VAC at full load INPUT EFFICIENCY (Typ.) 78% 83% 84% 87.5% 88% 88.5% 89% 90% AC CURRENT (Typ.) 1.1A/115VAC 0.6A/230VAC INRUSH CURRENT (Typ.) 35A/115VAC 65A/230VAC LEAKAGE CURRENT <1mA / 240VAC 105 ~ 135% rated output power OVERLOAD Protection type : Constant current limiting for Vo=50 ~ 100% of rated voltage, recovers automatically after fault condition is removed 3.96 ~ 4.62V 6 ~ 7V 9.4 ~ 10.9V 14.4 ~ 16.8V 18.8 ~ 21.8V 30 ~ 34.8V 41.4 ~ 48.6V 57.6 ~ 67.2V PROTECTION OVER VOLTAGE Protection type : Shut down o/p voltage, re-power on to recover Shut down o/p voltage, recovers automatically after temperature goes down OVER TEMPERATURE FUNCTION RC+/RC- : 0 ~ 0.8V= power on 4 ~ 10V = power off REMOTE CONTROL -40 ~ +60 (Refer toDerating Curv) WORKING TEMP. 20 ~ 90% RH non-condensing WORKING HUMIDITY ENVIRONMENT -40 ~ +85, 10 ~ 95% RH STORAGE TEMP., HUMIDITY 0.04%/ (0 ~ 50) TEMP. COEFFICIENT VIBRATION 10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes SAFETY STANDARDS UL62368-1,TUV BS EN/EN62368-1, AS/NZS62368.1, EAC TP TC 004 approved WITHSTAND VOLTAGE I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC SAFETY & ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25/ 70% RH EMC (Note 4) EMC EMISSION Compliance to BS EN/EN55032 (CISPR32) Class B, EN61000-3-2,-3, EAC TP TC 020 EMC IMMUNITY Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11,BS EN/EN55024,BS EN/EN61000-6-2,heavy industry level,criteria A,EAC TP TC 020 MTBF 295.7K hrs min. MIL-HDBK-217F (25) OTHERS DIMENSION 159*97*38mm (L*W*H) PACKING 0.56Kg 24pcs/15Kg/0.9CUFT ,1 ( / 2 ( ( 3 4 3 (+ ( 1 NOTE 31 5 6 ( 3 7 8 + - + ,39 - - ( - 1, 6 : 11 2 % 4 1 :1 2 - ( - - + < ( 1 =7 + > + ( A ((A (( ( - ,(( 1 2 < ( ( + ( ( =7 1 - ( =7 4 B=7C ( - 1D (as available on 3.5 100W Single Output with PFC Function HRP-100 series Mechanical Specification Case No.901I Unit:mm 152.5 1 2 3 4 5 6 7 CN100 SVR1 4.5 Terminal Pin No. Assignment 24 78 Pin No. Assignment Pin No. Assignment 159 1 AC/L 4,5 DC OUTPUT -V 2 AC/N 6,7 DC OUTPUT +V 6.5 150 3 FG 10 max. Remote ON/OFF (CN100) : JST B-XH or equivalent Pin No. Assignment Mating Housing Terminal 6-M3(Both Sides) L=6 1 RC- JST XHP JST SXH-001T or equivalent or equivalent 2 RC+ 22 117 Block Diagram ACTIVE RECTIFIERS RECTIFIERS EMI +V INRUSH POWER & I/P & FILTER CURRENT SWITCHING -V PFC FILTER LIMITING DETECTION O.L.P. O.T.P. CIRCUIT FG O.V.P. PFC PWM CONTROL CONTROL RC+ REMOTE CONTROL RC- Derating Curve Output Derating VS Input Voltage 100 100 90 80 80 70 60 60 40 50 20 40 -40 0 1020304050 60 70 (HORIZONTAL) 85 100 125 135 155 264 AMBIENT TEMPERATURE () INPUT VOLTAGE (V) 60Hz File Name:HRP-100-SPEC 2021-09-15 3.5 2-M3 L=4 LOAD (%) 8.2 9.5 1 2 9 LOAD(%) 18.5 65 I I 18 9 3.5 3.5 28.5 84.5 7 38 97