300W Single Output with PFC Function HRP-300 series Users Manual ) % & ( & ) * + & + + , , - . /-,, +0 + 1 +2 , . Bauart gepruft Sicherheit egelma ge od os be wac g www.tuv.com ID 2000000000 AS/NZS 62368.1 BS EN/EN62368-1 TPTC004 IEC62368-1 SPECIFICATION MODEL HRP-300-3.3 HRP-300-5 HRP-300-7.5 HRP-300-12 HRP-300-15 HRP-300-24 HRP-300-36 HRP-300-48 DC VOLTAGE 3.3V 5V 7.5V 12V 15V 24V 36V 48V RATED CURRENT 60A 60A 40A 27A 22A 14A 9A 7A CURRENT RANGE 0 ~ 60A 0 ~ 60A 0 ~ 40A 0 ~ 27A 0 ~ 22A 0 ~ 14A 0 ~ 9A 0 ~ 7A RATED POWER 198W 300W 300W 324W 330W 336W 324W 336W RIPPLE & NOISE (max.) Note.2 80mVp-p 90mVp-p 100mVp-p 120mVp-p 150mVp-p 150mVp-p 250mVp-p 250mVp-p OUTPUT VOLTAGE ADJ. RANGE 2.8 ~ 3.8V 4.3 ~ 5.8V 6.8 ~ 9V 10.2 ~ 13.8V 13.5 ~ 18V 21.6 ~ 28.8V 28.8 ~ 39.6V 40.8 ~ 55.2V VOLTAGE TOLERANCE Note.3 2.5% 2.0% 2.0% 1.0% 1.0% 1.0% 1.0% 1.0% LINE REGULATION 0.5% 0.5% 0.5% 0.3% 0.3% 0.2% 0.2% 0.2% LOAD REGULATION 1.0% 1.0% 1.0% 0.5% 0.5% 0.5% 0.5% 0.5% SETUP, RISE TIME 1000ms, 50ms/230VAC 2500ms, 50ms/115VAC at full load HOLD UP TIME (Typ.) 16ms/230VAC 16ms/115VAC at full load VOLTAGE RANGE Note.5 85 ~ 264VAC 120 ~ 370VDC FREQUENCY RANGE 47 ~ 63Hz POWER FACTOR (Typ.) PF>0.95/230VAC PF>0.99/115VAC at full load INPUT EFFICIENCY (Typ.) 80% 82% 86% 88% 88% 87% 88% 89% AC CURRENT (Typ.) 3.5A/115VAC 1.8A/230VAC INRUSH CURRENT (Typ.) 35A/115VAC 70A/230VAC LEAKAGE CURRENT <1.2mA / 240VAC 105 ~ 135% rated output power OVERLOAD Protection type : Constant current limiting, recovers automatically after fault condition is removed 3.96 ~ 4.62V 6 ~ 7V 9.4 ~ 10.9V 14.4 ~ 16.8V 18.8 ~ 21.8V 30 ~ 34.8V 41.4 ~ 48.6V 57.6 ~ 67.2V PROTECTION OVER VOLTAGE Protection type : Shut down o/p voltage, re-power on to recover Shut down o/p voltage, recovers automatically after temperature goes down OVER TEMPERATURE PSU turns on : 3.3 ~ 5.6V PSU turns off : 0 ~ 1V DC OK SIGNAL FUNCTION Load 3515% or RTH2 50 Fan on FAN CONTROL (Typ.) -40 ~ +70 (Refer toDerating Curv) WORKING TEMP. 20 ~ 90% RH non-condensing WORKING HUMIDITY ENVIRONMENT -40 ~ +85, 10 ~ 95% RH STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT /0.03% (0 ~ 50) VIBRATION 10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes SAFETY STANDARDS UL62368-1, TUV BS EN/EN62368-1, EAC TP TC 004, AS/NZS 62368.1 approved WITHSTAND VOLTAGE I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC SAFETY & ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25/ 70% RH EMC (Note 4) EMC EMISSION Compliance to BS EN/EN55032 (CISPR32) Class B, BS EN/EN61000-3-2,-3, EAC TP TC 020 Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11,BS EN/EN55024,BS EN/EN61000-6-2,heavy industry level,criteria A,EAC TP TC 020 EMC IMMUNITY MTBF 176K hrs min. MIL-HDBK-217F (25) OTHERS DIMENSION 199*105*41mm (L*W*H) 0.95Kg 15pcs/15.3Kg/0.79CUFT PACKING - , 0+3 , & , & 4 ( & & & 4 ,5 , NOTE 4 6 7 , & 4 8 9 5 &. & 5 -4: . & . , & . - 7 / 3 ) & & & / 3 . & & , 5 & < , =8 5 > & 5 , A ,, A ,, , . -,, 3 < , , 5 , & , =8 & & . , =8 B=8C , . D (as available on 1 7 2 8 300W Single Output with PFC Function HRP-300 series Mechanical Specification Case No.980A Unit:mm 4-M4 L=6 168.5 12.25 199 12.25 168.5 120 42.5 1 4-M4 L=5 2 3 4 FAN Air flow Terminal Pin No. Assignment 5 direction 6 Pin No. Assignment Pin No. Assignment 1 AC/L 4,5 DC OUTPUT -V 7 LED 2 AC/N 6,7 DC OUTPUT +V CN100 3 SVR FG Connector Pin No. Assignment (CN100) : 167.5 12.25 HRS DF11-08DP-2DS or equivalent Pin No. Assignment Mating Housing Terminal 12.25 167.5 1,2,4,6 NC 17max. 3 DC-OK HRS DF11-8DS HRS DF11-**SC 5 GND or equivalent or equivalent 7 +S 4-M4 L=6 8 -S PWM fosc : 70KHz Block Diagram +S ACTIVE RECTIFIERS RECTIFIERS EMI +V INRUSH POWER & I/P & FILTER CURRENT SWITCHING -V PFC FILTER LIMITING -S O.T.P. O.L.P. DC OK DETECTION CIRCUIT FG PFC PWM O.V.P. CONTROL CONTROL Derating Curve Output Derating VS Input Voltage 100 100 90 80 80 70 60 50 60 40 50 20 40 -40 0 10 20 30 40 50 60 70 (HORIZONTAL) 85 100 125 135 155 264 AMBIENT TEMPERATURE () INPUT VOLTAGE (V) 60Hz File Name:HRP-300-SPEC 2021-09-15 LOAD (%) 9.2 11 LOAD(%) 12.5 75 18 12.5 18 15 105 41 125