40W Single Output Industrial DIN Rail Power Supply M DR-40 series Bauar t gepruft Sicherheit egelma ge od o s be wac g www.tuv.com ID 2000000000 UL62368-1 SPECIFICATION TPTC004 BS EN/EN62368-1 IEC62368-1 MODEL MDR-40-5 MDR-40-12 MDR-40-24 MDR-40-48 DC VOLTAGE 5V 12V 24V 48V RATED CURRENT 6A 3.33A 1.7A 0.83A CURRENT RANGE 0 ~ 6A 0 ~ 3.33A 0 ~ 1.7A 0 ~ 0.83A RATED POWER 30W 40W 40.8W 39.8W RIPPLE & NOISE (max.) Note.2 80mVp-p 120mVp-p 150mVp-p 200mVp-p OUTPUT VOLTAGE ADJ. RANGE 5 ~ 6V 12 ~ 15V 24 ~ 30V 48 ~ 56V VOLTAGE TOLERANCE Note.3 2.0% 1.0% 1.0% 1.0% LINE REGULATION 1.0% 1.0% 1.0% 1.0% LOAD REGULATION 1.0% 1.0% 1.0% 1.0% SETUP, RISE TIME Note.5 500ms, 30ms/230VAC 500ms, 30ms/115VAC at full load HOLD UP TIME (Typ.) 50ms/230VAC 20ms/115VAC at full load VOLTAGE RANGE 85 ~ 264VAC 120 ~ 370VDC FREQUENCY RANGE 47 ~ 63Hz EFFICIENCY (Typ.) 78% 86% 88% 88% INPUT AC CURRENT (Typ.) 1.1A/115VAC 0.7A/230VAC INRUSH CURRENT (Typ.) COLD START 30A/115VAC 60A/230VAC <1mA / 240VAC LEAKAGE CURRENT 105 ~ 150% rated output power OVERLOAD Protection type : Constant current limiting, recovers automatically after fault condition is removed PROTECTION 6.25 ~ 7.25V 15.6 ~ 18V 31.2 ~ 36V 57.6 ~ 64.8V OVER VOLTAGE Protection type : Shut down o/p voltage, re-power on to recover FUNCTION DC OK SIGNAL Relay contact rating(max.): 30V/1A resistive -20 ~ +70 (Refer toDerating Curv) WORKING TEMP. 20 ~ 90% RH non-condensing WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY -40 ~ +85, 10 ~ 95% RH TEMP. COEFFICIENT 0.03%/ (0 ~ 50) Component : 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes Mounting : Compliance to IEC60068-2-6 VIBRATION UL508, UL62368-1, TUV BS EN/EN62368-1,Class I, Div. 2 Group A, B, C, D Hazardous Locations T4, EAC TP TC 004, SAFETY STANDARDS BSMI CNS14336-1, AS/NZS 60950.1 approved WITHSTAND VOLTAGE I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC SAFETY & I/P-O/P, I/P-FG, O/P-FG:>100M Ohms / 500VDC / 25/ 70% RH ISOLATION RESISTANCE EMC (Note 4) Compliance to BS EN/EN55032 (CISPR32), BS EN/EN61204-3 Class B, BS EN/EN61000-3-2,-3, EAC TP TC 020, CNS13438 Class B EMC EMISSION Compliance to BS EN/EN61000-4-2, 3, 4, 5, 6, 8, 11, BS EN/EN55024, BS EN/EN61000-6-2, BS EN/EN61204-3, heavy industry level, EMC IMMUNITY criteria A, EAC TP TC 020 MTBF 301.7K hrs min. MIL-HDBK-217F (25) 40*90*100mm (W*H*D) OTHERS DIMENSION 0.3Kg 42pcs/13.6Kg/0.82CUFT PACKING NOTE (as available on 40W Single Output Industrial DIN Rail Power Supply M DR-40 series Mechanical Specification Case No.962A Unit:mm 35 40 100 5 5 5 5 5 +V +V -V -V DC OK DC OK + +V ADJ N L 7.5 7.5 Install DIN rail TS35/7.5 or TS35/15 Block Diagram fosc : 60KHz DC OK RECTIFIERS RECTIFIERS +V EMI POWER I/P & & FILTER SWITCHING -V FILTER FILTER O.C.P. DETECTION FG CIRCUIT CONTROL O.L.P. O.V.P. DC OK Relay Contact Contact Close PSU turns on / DC OK. Contact Open PSU turns off / DC Fail. Contact Ratings (max.) 30V/1A resistive load. Derating Curve Output Derating VS Input Voltage 100 100 90 80 80 70 60 60 40 50 20 40 -20 0 10 20 30 45 55 60 70 (VERTICAL) 85 95 100 115 120 140 160 180 200 220 240 264 AMBIENT TEMPERATURE () INPUT VOLTAGE (VAC) 60Hz File Name:MDR-40-SPEC 2021-06-21 LOAD (%) 90 LOAD (%)