120W Single Output Power Supply or Battery Charger PA/ PB-120 series UL60950-1 UL60950-1 TPTC004 (for PA/PB-120P-C) (for PA/PB-120-C) (for PA/PB-120-P) P A 120 P 13 C S:Power Supply A:Voltage detector :O.D.M. number B:Current detector P:Open P.C.B. C:With case P:With PFC N:None PFC 13:13.8V 27:27.6V 54:55.2V SPECIFICATION MODEL PA/PB-120-13 PA/PB-120-27 PA/PB-120-54 DC VOLTAGE 13.8V 27.6V 55.2V RATED CURRENT 7.2A 4.3A 2.2A CURRENT RANGE 0 ~ 7.2A 0 ~ 4.3A 0 ~ 2.2A OUTPUT RATED POWER 99.36W 118.68W 121.44W PA series voltage 105%1%: RED / 105%1%:GREEN LED INDICATED PB series load 46%10%: GREEN / 46%10%:RED VOLTAGE RANGE 88 ~ 132VAC / 176 ~ 264VAC selected by switch 248 ~ 370VDC FREQUENCY RANGE 47 ~ 63Hz POWER FACTOR (Typ.) >0.65 (with PFC series) INPUT EFFICIENCY (Typ.) 73% 79% 79% 3A/115VAC 1.5A/230VAC AC CURRENT (Typ.) INRUSH CURRENT (Typ.) COLD START 25A/115VAC 50A/230VAC LEAKAGE CURRENT <1.5mA / 240VAC 90 ~ 110% rated output power OVERLOAD Protection type : Constant current limiting, recovers automatically after fault condition is removed 15 ~ 17V 30 ~ 35V 60 ~ 66V PROTECTION OVER VOLTAGE Protection type : Hiccup mode, recovers automatically after fault condition is removed RTH270 10 detect on RTH2 thermistor OVER TEMPERATURE Protection type : Shut down o/p voltage, recovers automatically after temperature goes down -10 ~ +45 (Refer toDerating Curv) WORKING TEMP. 20 ~ 90% RH non-condensing WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY -20 ~ +85, 10 ~ 95% RH TEMP. COEFFICIENT 0.05%/ (0 ~ 45) VIBRATION 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes SAFETY STANDARDS UL60950-1, LVD BS EN/EN62368-1, EAC TP TC 004 approved WITHSTAND VOLTAGE I/P-O/P:3KVAC I/P-FG:2.0KVAC O/P-FG:0.5KVAC SAFETY & ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25/ 70% RH EMC (Note 4) EMC EMISSION Compliance to BS EN/EN55032 (CISPR32) Class B, BS EN/EN61000-3-2,-3, EAC TP TC 020 EMC IMMUNITY Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN55024, light industry level, criteria A, EAC TP TC 020 149.6K hrs min. MIL-HDBK-217F (25) MTBF PCB Type:144*90*33mm External case type:180*96*49mm (L*W*H) OTHERS DIMENSION External case type: 1.1Kg 16pcs / 17.9Kg / 1.56CUFT(without PFC) 1.24Kg 16pcs / 20.1Kg / 1.56CUFT(with PFC) PACKING PCB Type : 0.36Kg 36pcs / 14Kg / 0.99CUFT(without PFC) 0.5Kg 36pcs / 19Kg / 0.99CUFT(with PFC) NOTE FUSE 4-3.8 120W Single Output Power Supply or Battery Charger PA/ PB-120 series Mechanical Specification Case No. PS-120A Unit:mm 3 pin XLR 1 2 3 CASE: Output cable length=183cm 5cm Pin No. Assignment 1 DC OUTPUT +V 2,3 DC OUTPUT -V PCB: AC Input Connector (CN1) : JST B3P-VH or equivalent Pin No. Assignment Mating Housing Terminal 180 1 AC/L JST VHR JST SVH-21T-P1.1 2 No Pin or equivalent or equivalent 144 3 AC/N 134 5 DC Output Connector (CN3) : JST B4P-VH or equivalent Pin No. Assignment Mating Housing Terminal CN3 1,2 -V JST VHR JST SVH-21T-P1.1 or equivalent or equivalent 3,4 +V 12VDC FAN Output Connector (CN4) : JST B2B-XH or equivalent ADJ. Pin No. Assignment Mating Housing Terminal CN4 LED 1 +V JST XHP JST SXH-001T-P0.6 1 2 or equivalent or equivalent 2 -V + - CN5 1 2 3 SHORT FOR 115V CN1 OPEN FOR 230V 115/230V selected by switch Connector (CN5) : JST B2P-VH or equivalent Switch Assignment Mating Housing Terminal 115V Short JST VHR JST SVH-21T-P1.1 or equivalent or equivalent 230V Open Derating Curve Charging Curve Vout Iout Bat. Voltage 105% 100% 100 Charging Current Open frame series 100% 17.8CFM air cooling 80 (L=15cm face HS) 45% Other series T Red Green 60 LED COLOR Type A:Voltage detecter,pulse charger 40 Vout Iout Bat. Voltage 105% 100% 20 Charging Current 100% -10 0 10 20 30 40 50 60 (HORIZONTAL) T AMBIENT TEMPERATURE () Red Green LED COLOR Type B:Current detecter,2 voltage section File Name:PA,PB-120-SPEC 2021-06-01 LOAD (%) 90 3 max. 33 80 5 F4A/250V 1 2 3 4 -V +V 49 115