120W PWM Output LED Driver PWM-120 series 05 IP67 * 4 ( 67 1 11 8 9 : &) - 6 A 1 9 1 23 7 = > & 9 <( = > - ) ) % & ( )* * +,*&- % &). + /0 &- 1 23 % & 4 5 & B = + (2 +,*> B C File Name:PWM-120-SPEC 2016-06-21120W PWM Output LED Driver PWM-120 series SPECIFICATION MODEL PWM-120-12 PWM-120-24 PWM-120-36 PWM-120-48 DC VOLTAGE 12V 24V 36V 48V RATED CURRENT 10A 5A 3.4A 2.5A RATED POWER 120W 120W 122.4W 120W DIMMING RANGE 0 ~ 100% OUTPUT PWM FREQUENCY (Typ.) 300Hz SETUP, RISE TIME Note.2 500ms, 80ms/ 230VAC or 115VAC HOLD UP TIME (Typ.) 16ms/230VAC or 115VAC 90 ~ 305VAC 127 ~ 431VDC VOLTAGE RANGE Note.3 (Please refer toSTATIC CHARACTERISTI section) FREQUENCY RANGE 47 ~ 63Hz PF>0.97/115VAC, PF>0.96/230VAC, PF>0.94/277VAC full load POWER FACTOR (Typ.) (Please refer toPOWER FACTOR (PF) CHARACTERISTI section) THD< 20%( load60%/115VAC, 230VAC load 75%/277VAC) TOTAL HARMONIC DISTORTION (Please refer to TOTAL HARMONIC DISTORTION section) EFFICIENCY (Typ.) 88% 90% 90% 90.5% INPUT AC CURRENT (Typ.) 1.3A / 115VAC 0.65A / 230VAC 0.55A / 277VAC INRUSH CURRENT (Typ.) COLD START 60A(twidth=520 s measured at 50% Ipeak) at 230V AC Per NEMA 410 MAX. NO. of PSUs on 16A 4 units (circuit breaker of type B) / 6 units (circuit breaker of type C) at 230VAC CIRCUIT BREAKER LEAKAGE CURRENT <0.25mA / 277VAC <0.5W %& ( 108 ~ 120% rated output power OVERLOAD Hiccup mode, recovers automatically after fault condition is removed SHORT CIRCUIT Shut down o/p voltage, re-power on to recover 15 ~ 17V 28 ~ 34V 41 ~ 46V 54 ~ 60V PROTECTION OVER VOLTAGE Shut down o/p voltage, re-power on to recover Shut down o/p voltage, re-power on to recover OVER TEMPERATURE WORKING TEMP. Tcase=-40 ~ +90 (Please refer to OUTPUT LOAD vs TEMPERATURE section) MAX. CASE TEMP. Tcase=+90 20 ~ 95% RH non-condensing WORKING HUMIDITY ENVIRONMENT -40 ~ +80, 10 ~ 95% RH STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT 0.03%/ (0 ~ 45,except 0 ~ 40 for 12V) VIBRATION 10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes UL8750( type HL ), CSA C22.2 No. 250.13-12 ENEC EN61347-1, EN61347-2-13 independent, EN62384, SAFETY STANDARDS Note.5 IP67 approved Design refer to EN60335-1 WITHSTAND VOLTAGE I/P-O/P:3.75KVAC SAFETY & ISOLATION RESISTANCE I/P-O/P:100M Ohms / 500VDC / 25/ 70% RH EMC EMC EMISSION Note.6 Compliance to EN55015, EN61000-3-2 Class C ( load60%) EN61000-3-3 Compliance to EN61000-4-2,3,4,5,6,8,11 EN61547, light industry level (surge immunity Line-Line 2KV) EMC IMMUNITY MTBF 860.4K hrs min. Telcordia SR-332 (Bellcore) 228.7K hrs min. MIL-HDBK-217F (25) 191*63*37.5mm (L*W*H) OTHERS DIMENSION 0.97Kg 15pcs/15.6Kg/0.87CUFT PACKING & :D- ( * ) & NOTE & & C- -1 6 B - B1C-1 A & (& &- D: D99 & +&- 4 &C 4 4 & )&- =E8 ) & + E8 ) & E8 33+( E8 32 )& > & : & 2&- 5 ) - = - > 3) & 3& : F < & & File Name:PWM-120-SPEC 2016-06-21