2000W Rack Mountable Front End Rectifier RCP-2000 series Users Manual B C C +( C & 2 C .& 7& 9 &&)- C C &)-&7& 9 ( Bauart gepruft Sicherheit egelma ge od os be wac g www.tuv.com ID 2000000000 UL62368-1 BS EN/EN62368-1 TPTC004 IEC62368-1 % : 7 0 /% ( 9 6 : + < : = 6 = : *1 7 9 % - &+ 6 1 56 > = = = = ( % & 0 ( ) * + , -./% ) 1 2 ) 3 4 56 1 1 7 &8 &+ 1 & 91 1 3 1 1 3 5 &1 ) 5 3 + ) = = &> &+A 1 & 1 ) > ) ) > 5 1 5 &1 ) > ) ) File Name:RCP-2000-SPEC 2021-2021-08-272000W Rack Mountable Front End Rectifier RCP-2000 series SPECIFICATION MODEL RCP-2000-12 RCP-2000-24 RCP-2000-48 DC VOLTAGE 12V 24V 48V RATED CURRENT 100A 80A 42A CURRENT RANGE 0 ~ 100A 0 ~ 80A 0 ~ 42A RATED POWER 1200W 1920W 2016W RIPPLE & NOISE (max.) Note.2 150mVp-p 200mVp-p 300mVp-p OUTPUT VOLTAGE ADJ. RANGE 10.5 ~ 14V 21 ~ 28V 42 ~ 56V VOLTAGE TOLERANCE Note.4 2.0% 1.0% 1.0% LINE REGULATION 1.0% 0.5% 0.5% LOAD REGULATION 1.0% 0.5% 0.5% SETUP, RISE TIME 1500ms, 60ms/230VAC at full load HOLD UP TIME (Typ.) 16ms/230VAC at 75% load 10ms/230VAC at full load VOLTAGE RANGE Note.5,6 90 ~ 264VAC 127 ~ 320VDC FREQUENCY RANGE 47 ~ 63Hz POWER FACTOR (Typ.) 0.98/230VAC at full load EFFICIENCY (Typ.) 86% 90.5% 92% INPUT 13A/115VAC 7A/230VAC 16A/115VAC 10A/230VAC 16A/115VAC 10A/230VAC AC CURRENT (Typ.) INRUSH CURRENT (Typ.) COLD START 50A LEAKAGE CURRENT <1.1mA / 230VAC 105 ~ 125% rated output power OVERLOAD Protection type : Constant current limiting, unit will shut down o/p voltage after 5 sec. re-power on to recover 14.7 ~ 17.5V 29.5 ~ 35V 57.6 ~ 67.2V PROTECTION OVER VOLTAGE Protection type : Shut down o/p voltage, re-power on to recover OVER TEMPERATURE Shut down o/p voltage, recovers automatically after temperature goes down 5V 0.3A, 12V 0.8A AUXILIARY POWER REMOTE ON-OFF CONTROL Please refer to the Function Manual Compensate voltage drop on the load wiring up to 0.5V REMOTE SENSE OUTPUT VOLTAGE PROGRAMMABLE Adjustment of output voltage is allowable to 90 ~ 110% of nominal output voltage. Please refer to the Function Manual. FUNCTION The isolated TTL signal out, Please refer to the Installation Manual DC OK SIGNAL The isolated TTL signal out, Please refer to the Installation Manual AC OK SIGNAL Logic Hig for over temperature warning, Please refer to the Installation Manual, isolated signal OVER TEMP WARNING The isolated TTL signal out, Please refer to the Installation Manual FAN FAIL SIGNAL -35 ~ +70 (Refer toDerating Curv) WORKING TEMP. 20 ~ 90% RH non-condensing WORKING HUMIDITY STORAGE TEMP., HUMIDITY -40 ~ +85, 10 ~ 95% RH non-condensing ENVIRONMENT TEMP. COEFFICIENT 0.03%/ (0 ~ 50) VIBRATION 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes UL62368-1, CSA C22.2 No. 62368-1, TUV BS EN/EN62368-1, EAC TP TC 004 approved SAFETY STANDARDS I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.7KVDC WITHSTAND VOLTAGE ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25/ 70% RH Parameter Standard Test Level / Note Conducted BS EN/EN55032 (CISPR32) Class B EMC EMISSION Radiated BS EN/EN55032 (CISPR32) Class A Harmonic Current BS EN/EN61000-3-2 ----- Voltage Flicker BS EN/EN61000-3-3 ----- BS EN/EN55024, BS EN/EN61000-6-2 SAFETY & Parameter Standard Test Level / Note EMC ESD BS EN/EN61000-4-2 Level 3, 8KV air Level 2, 4KV contact (Note 7) Radiated BS EN/EN61000-4-3 Level 3 EFT / Burst BS EN/EN61000-4-4 Level 3 EMC IMMUNITY Surge BS EN/EN61000-4-5 Level 4, 4KV/Line-Earth Level 3, 2KV/Line-Line Conducted BS EN/EN61000-4-6 Level 3 Magnetic Field BS EN/EN61000-4-8 Level 4 >95% dip 0.5 periods, 30% dip 25 periods, Voltage Dips and Interruptions BS EN/EN61000-4-11 >95% interruptions 250 periods MTBF 145.1K hrs min. Telcordia SR-332 (Bellcore) 37.4K hrs min. MIL-HDBK-217F (25) OTHERS DIMENSION 295*127*41mm (L*W*H) PACKING 2Kg 6pcs/13Kg/1.04CUFT &) % =* 0 /% 1 ( ) NOTE ) D 5 E & A )& D .2 ) 0) 1 ) & <) .) * > 1 ) () ) ) -. Please contact MEANWELL for 320~370VDC application. 2) * 4 ) % 5 3 2 C0- & ) * 4 5 ) : 5 1 F 5 )G 7