480W Three Phase Industrial DIN RAIL with PFC Function T DR-480 series File Name:TDR-480-SPEC 2016-11-24480W Three Phase Industrial DIN RAIL with PFC Function T DR-480 series SPECIFICATION MODEL TDR-480-24 TDR-480-48 DC VOLTAGE 24V 48V RATED CURRENT 20A 10A CURRENT RANGE 0 ~ 20A 0 ~ 10A RATED POWER 480W 480W RIPPLE & NOISE (max.) Note.2 150mVp-p 150mVp-p OUTPUT VOLTAGE ADJ. RANGE 24 ~ 28V 48 ~ 55V VOLTAGE TOLERANCE Note.3 1.0% 1.0% LINE REGULATION 0.5% 0.5% LOAD REGULATION 1.0% 1.0% SETUP, RISE TIME 1200ms, 60ms/400VAC 800ms, 60ms/500VAC at full load HOLD UP TIME (Typ.) 20ms / 400VAC 20ms / 500VAC at full load VOLTAGE RANGE Note.4 Three-Phase 340 ~ 550VAC (Dual phase operation possible) 480 ~ 780VDC FREQUENCY RANGE 47 ~ 63Hz POWER FACTOR (Typ.) PF0.9/400VAC PF0.88/500VAC at full load EFFICIENCY (Typ.) 92.5% 93% INPUT 0.85A/400VAC 0.7A/500VAC AC CURRENT (Typ.) INRUSH CURRENT (Typ.) COLD START 50A LEAKAGE CURRENT <3.5mA / 530VAC 105 ~ 130% rated output power OVERLOAD Protection type : Constant current limiting, unit will shut down after 3 sec. ,re-power on to recover 29 ~ 33V 56 ~ 65V PROTECTION OVER VOLTAGE Protection type : Shut down o/p voltage, re-power on to recover OVER TEMPERATURE Shut down o/p voltage, recovers automatically after temperature goes down -30 ~ +70 (Refer toDerating Curv) WORKING TEMP. Note.5 20 ~ 95% RH non-condensing WORKING HUMIDITY STORAGE TEMP., HUMIDITY -40 ~ +85, 10 ~ 95% RH ENVIRONMENT TEMP. COEFFICIENT 0.03%/ (0 ~ 50) Component:10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes Mounting: Compliance to IEC60068-2-6 VIBRATION SAFETY STANDARDS UL508, IEC60950-1 CB approved by UL WITHSTAND VOLTAGE I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC O/P-DC OK(optional):0.5KVAC SAFETY & ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:>100M Ohms / 500VDC / 25/ 70% RH EMC (Note 4) Parameter Standard Test Level / Note Conducted EN55022 (CISPR22), EN55032(CISPR32) / EN61204-3 Class B EMC EMISSION Radiated EN55022 (CISPR22), EN55032(CISPR32) / EN61204-3 Class B Harmonic Current EN61000-3-2 Class A Voltage Flicker EN61000-3-3 ----- EN55024 , EN60601-1-2, EN61204-3 Parameter Standard Test Level / Note ESD EN61000-4-2 Level 4, 15KV air Level 4, 8KV contact Radiated Field EN61000-4-3 Level 3 EFT / Burst EN61000-4-4 Level 3 EMC IMMUNITY Surge EN61000-4-5 Level 4, 2KV / Line-Line, Level 4, 4KV/ Line-Earth Conducted EN61000-4-6 Level 3 Magnetic Field EN61000-4-8 Level 4 95% dip 0.5 periods, 30% dip 25 Voltage Dips and Interruptions EN61000-4-11 periods 95% interruptions 250 periods MTBF 391.7K hrs min. Telcordia SR-332(Bellcore) 108.2K hrs min. MIL-HDBK-217F (25) OTHERS DIMENSION 85.5*125.2*128.5mm (W*H*D) 1.51Kg 8pcs/13Kg/1.16CUFT PACKING NOTE For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies. (as available on