D1U3CS-W-1300F-12-Hx4EC Series 81mm Front End AC-DC Power Converter www.murata-ps.com PRODUCT OVERVIEW The D1U3CS-W-1300F-12-Hx4EC are high ef ciency 1300W power factor corrected front end supplies with a 12V main output and a 5V or 3.3V (20W) standby. Active current sharing is provided to allow up to eight (8) supplies to be operated in parallel. The supplies may be hot plugged and include integral isolation devices. The power modules are fully protected from overload and overvoltage and are able to auto-recover from overtemperature faults. Status LEDS are provided on the front panel and additional control and status reporting is provided by hardware logic signals and via a PMBus digital interface. 3 A low pro le sub 1U height enclosure provides a power density of >23W/in that is ideal for delivering reliable, ef cient power to servers, workstations, storage systems and other 12V distributed power systems. ORDERING GUIDE Power Output Main Standby FEATURES Model Number Air ow AC Line & Temp AC Line & Temp Output Output (108-264V 40C) (90-264V 50C) Extended Power Range to 1300W D1U3CS-W-1300F-12-HA4EC 5V 1300W 1200W 12V Back to Front 1.57 (1U) x 11.0 x 3.2 D1U3CS-W-1300F-12-HC4EC 3.3V 92% ef ciency at 50% FL INPUT CHARACTERISTICS 12VDC Main output Parameter Conditions Min Typ Max Units Voltage Operating Range 90 115/230 264 Vac 3.3VSB or 5VSB output (20W) Input Frequency 47 50/60 63 Hz 3 >23W/in power density Turn-on Input Voltage Ramp Up 81 85 89 Vac N+1 Redundancy Capable hot plug/swap (up to Turn-off Input Voltage Ramp Down 70.5 74.3 78.0 8 modules in parallel) Maximum Current VIN = 200Vac 1300W 40C (max) 8 Arms Maximum Current VIN = 90Vac 1200W 50C (max) 15 Active current sharing on 12V main output Inrush Current Cold start between 0 to 200ms 25 Apk integral MOSFET ORING Power Factor At 230Vac FL 0.99 Over-Voltage, Over-Current Over-Temperature 20% FL 88 Protection Ef ciency (230Vac) excluding fan load 50% FL 92 % Internal variable speed cooling fans 100% FL 92 PMBus Power Management Bus OUTPUT VOLTAGE CHARATERISTICS RoHS Compliant Output Conditions Min Typ Max Units Parameter Voltage Voltage Set Point Accuracy 12 Vdc Line & Load Regulation 11.4 12.6 1 Ripple & Noise 20MHz Bandwidth 150 mV P-P 12V Output Current (230Vac) 0 108.3 A Output Current (120Vac) 108.3 Output Current (90Vac) 100 Load Capacitance 30,000 F Voltage Set Point 3.3 Vdc Line & Load Regulation 3.2 3.4 1 3.3VSB Ripple Voltage & Noise 20MHz Bandwidth 100 mV P-P Output Current 0 6 A Load Capacitance 10,000 F Voltage Set Point 5.0 www.murata-ps.com/en/3d/acdc.html Vdc www.murata-ps.com/en/3d/acdc.html Line & Load Regulation 4.85 5.1 www.murata-ps.com/en/3d/acdc.html 1 5VSB Ripple Voltage & Noise 20MHz Bandwidth 50 mV P-P www.murata-ps.com/en/3d/acdc.html Output Current 0 4 A www.murata-ps.com/en/3d/acdc.html Load Capacitance 10,000 F 1 Ripple and noise are measurements are to be performed with a parallel combination of a 0.1F ceramic capacitor and 10F tantalum Available now at capacitance on each of the power module output measurement nodes. A short coaxial cable shall be used. www.murata-ps.com/en/3d/acdc.html CB Test Certi cate and Test Report For full details go to www.murata-ps.com/rohs www.murata-ps.com/support D1U3CS-W-1300F-12-Hx4EC.A01 Page 1 of 5D1U3CS-W-1300F-12-Hx4EC Series 81mm Front End AC-DC Power Converter OUTPUT CHARACTERISTICS Parameter Conditions Min Typ Max Units Remote Sense Compensation at full load (total loop for positive & negative connections) 120 mV Output Rise (Monotonic) 10% to 95% rise time No voltage excursion AC Ramp Up 1.5 2.5 s Startup Time PS ON activation 150 ms 12V, 50-100% step load 1A/s 600 Transient Response mV 3.3/5VSB 50-100% step load 1A/s 165/250 Current Sharing Accuracy (up to 8 in parallel) At 100% load 7 % Hot Swap Transients 5% Hold Up Time FL (Full Load) 12 ms ENVIRONMENTAL CHARACTERISTICS Parameter Conditions Min Typ Max Units Storage Temperature Range Non-Condensing -40 70 1200W 0 50 C Operating Temperature Range 1300W 0 40 Operating Humidity Non-Condensing 5 90 % Storage Humidity 595 Altitude (no derating at 40C) 3000 m Shock Operating 30 G Sinusoidal Vibration Operational, 2.0G 5-500Hz MTBF Telcordia SR-332 M1C1 40C 500 K Hours CSA/UL C22.2 No.60950-1-07, Amendment 1 2011 ANSI/UL 60950-1-2011 nd Safety Approvals (Standards) IEC 60950-1:2005, (2 Edition) + A1:2009 EN 60950-1:2006 + A11:2009 +A1 :2010 +A12:2011 CE Marking per LVD DIRECTIVE 2006/95/ECS Input Fusing Internal 16A/250V rated fast blow in AC line 90KHz for the PFC Boost Converter Switching Frequency 130KHZ for the Main Output Converter Material Flammability UL94-V0 Weight 3.15/1.43 Lbs/kg PROTECTION CHARACTERISTICS Output Voltage Parameter Conditions Min. Typ. Max. Units N/A Over-Temperature Auto re-start 57 60 63 C Over-Voltage Latching 13.3 14.5 V 12V (Main) Over-Current (1300W) Latching 115 125 A Over-Current (1200W) Latching 108 118 Over-Voltage Latching 3.9 4.3 V 3.3VSB Over-Current Auto-recovery 6.5 9.0 A Over-Voltage Latching 5.6 6.0 V 5VSB Over-Current Auto-recovery 5.0 6.5 A ISOLATION CHARACTERISTICS Parameter Conditions Min. Typ. Max. Units Input to Output Re-enforced 3000 Vrms Insulation Safety Rating/Test Voltage Input to Chassis - Basic 1500 Vrms Isolation Output to Chassis (Ground) 500 Vdc www.murata-ps.com/support D1U3CS-W-1300F-12-Hx4EC.A01 Page 2 of 5