MVAD040 Series www.murata-ps.com 40W 2 x 4 AC-DC Power Supply Converter DESCRIPTION The MVAD040 series switching power supplies utilize advanced component and circuit technologies to deliver high ef ciency. Designed for Medical, Telecom, and Industrial applications to satisfy 1U height design considerations, the MVAD040 Series measures only 2.0 x 4.0 x 1.3 . All models offer universal AC input and compliance to worldwide safety and EMC standards. ORDERING GUIDE Model Number Natural Convection Cooling Main Output (V1) MVAD040-05 30W 5V MVAD040-12 12V MVAD040-24 40W 24V FEAATTURESURES MVAD040-48 48V ITE (2nd Ed.) and Medical (3rd ed.) MOPP safety approved INPUT CHARACTERISTICS 30-40W compact high density Parameter Conditions Min. Typ. Max. Units 2 x 4 standard footprint Single phase 90 120/230 264 Vac Input Voltage Operating Range DC 120 300 Vdc High ef ciency up to 89% Input Frequency 47 50/60 63 Hz Universal AC input Turn-on Input Voltage Input rising at full load 50 70 Vac Low pro le - 1U package Turn-off Input Voltage Input falling at full load 50 70 Input Current 90Vac input, full load 0.9 A Convection-cooled operation up to 40W At 264Vac, at 25C cold Complies with 5000m altitude Inrush Current 60 Apk start RoHS compliant UL Class I and II approved OUTPUT CHARACTERISTICS Main Output Line, Load, Cross Typical Ef ciency Less than 0.3W no load input power 3 Model Number Load Current Peak Load Load Capacitance Voltage (V1) Regulation 230Vac full load Complies with ErP/Energy Star requirement MVAD040-05 5V 0 to 6A 0 to 1200F 2% 80% average efciency>85.3% (24V and 48V) MVAD040-12 12V 0 to 3.34A 5.0A 0 to 680F 2% 87% MVAD040-24 24V 0 to 1.67A 2.5A 0 to 330F 2% 88% MVAD040-48 48V 0 to 0.84A 1.25A 0 to 220F 2% 89% Main Output Characteristics (all models) Parameter Conditions Min. Max. Units Transient Response (MVAD040-05 only) 8 50% load step, 1A/sec slew rate % Transient Response (all other models) 5 Settling Time to 1% of Nominal 200 sec Turn On Delay After application of input power 1 sec Output Voltage Rise Monotonic, 0 to 100% load 50 msec Setpoint Accuracy 120Vac, 40W, 25C 0.5 % Output Holdup, MVAD040-05 only 115Vac, 100% load 20 msec www.murata-ps.com/en/3d/acdc.html Output Holdup, all other models 115Vac, 100% load 15 msec www.murata-ps.com/en/3d/acdc.html Temperature Coef cient 0.02 %/C www.murata-ps.com/en/3d/acdc.html 1 Ripple Voltage & Noise 1% www.murata-ps.com/en/3d/acdc.html 1. Ripple and noise are measured with 0.1 F of ceramic capacitance and 47 F of electrolytic capacitance on www.murata-ps.com/en/3d/acdc.html each of the power supply outputs. The output noise requirements apply over a 0 Hz to 20 MHz bandwidth. A www.murata-ps.com/en/3d/acdc.html short coaxial cable with 50ohm scope termination is used. 2. Unless otherwise speci ed all readings are taken at 120Vac input and 25 C ambient temperature. Available now at 3. Peak current lasting <15 seconds with a maximum 10% duty cycle and with an average output power of 40W. www.murata-ps.com/en/3d/acdc.html CB Test Certi cate and Test Report For full details go to www.murata-ps.com/rohs www.murata-ps.com/support MVAD040.B01 Page 1 of 6 *LAST TIME BUY: 2/28/2019. CLICK HERE FOR DISCONINUANCE NOTICES.MVAD040 Series 40W 2 x 4 AC-DC Power Supply Converter ENVIRONMENTAL CHARACTERISTICS Parameter Conditions Min. Typ. Max. Units Storage Temperature Range -40 85 See thermal derating curves -20 70 C Operating Temperature Range Start up -20 Operating Humidity Non-condensing 10 95 % For Class I ITE Equipment deployment -200 5000 Operating Altitude m Other -200 2000 MTBF Telcordia SR-332 M1C3 25C 1M Hours Operating, IEC60068-2-27, half-sine 5G, 6ms, Complies 3 times per face, 6 faces Shock Non-operating, IEC60068-2-27, half-sine, Complies 30G, 18ms, 3 times per face, 6 faces Operating, IEC60068-2-6, 1.0G, 10-150Hz, Complies 10minutes per axis, on all 3 axes Vibration Non-operating, IEC60068-2-6, 2.0G, Complies 10-150Hz, 10minutes per axis, on all 3 axes IEC60950-1:2005 (2nd Edition) Am1:2009 UL60950-1 2nd Edition,2011-12-19, CSA C22.2 No. 60950-1-07, 2nd Edition,2011-12 EN60950-1:2006 + A11:2009 + A1:2010 + A12:2011 Safety IEC60601-1:2005 + CORR.1(2006) + CORR.2(2007) ANSI/AAMI ES60601-1 (2005+C1:09 + A2:10), CSA-C22.2 No. 60601-1(2008), MOPP CE Marking per LVD Warranty 2 years Outside Dimensions 2.0 x 4.0 x 1.3 (50.8mm x 101.6mm x 33.02mm) 0.28lbs (127g) typical (MVAD040-05 only) Weight 0.27lbs (123g) typical (all other models) PROTECTION CHARACTERISTICS Parameter Conditions Min. Typ. Max. Units Overvoltage Protection Latching (60% load) 110 160 %V1 Overcurrent Protection, MVAD040-05 only Hiccup mode 110 160 %A Overcurrent Protection, all other models Hiccup mode 170 240 %A ISOLATION CHARACTERISTICS Parameter Conditions Min. Typ. Max. Units Primary to Earth Ground (1xMOPP) 1500 Vac Isolation Primary to Secondary (2xMOPP)4 4000 Secondary to Earth Ground 500 Vdc 240Vac, 60Hz, 25C 300 Leakage Current (under normal conditions) 264Vac, 60Hz, 25C 350 A Touch Current 264Vac, 60Hz, 25C 100 EMISSIONS AND IMMUNITY Characteristic Standard Compliance Input Current Harmonics IEC/EN 61000-3-2 Class A Voltage Fluctuation and Flicker IEC/EN 61000-3-3 Complies EN 55022 Class B, Class A (at Class II equipment) Conducted Emissions FCC Part 15 Class B, Class A (at Class II equipment) ESD Immunity IEC/EN 61000-4-2 Level 4, Criterion A Radiated Field Immunity IEC/EN 61000-4-3 Level 2, Criterion A Electrical Fast Transient Immunity IEC/EN 61000-4-4 Level 3, Criterion A Surge Immunity IEC/EN 61000-4-5 Level 4, Criterion A RF Conducted Immunity IEC/EN 61000-4-6 Level 2, Criterion A Magnetic Field Immunity IEC/EN 61000-4-8 Level 2, Criterion A Voltage dips, interruptions IEC/EN 61000-4-11 Level 3, Criterion B 4. At class I equipment. www.murata-ps.com/support MVAD040.B01 Page 2 of 6