MVAD065 Series www.murata-ps.com 65W 2 x 4 AC-DC Power Supply Converter DESCRIPTION The MVAD065 series switching power supplies utilize advanced component and circuit technologies to deliver high efficiency. Designed for Medical, Telecom, and Industrial applications to satisfy 1U height design considerations, the MVAD065 Series measures only 2.0 x 4.0 x 1.3. All models offer universal AC input and compliance to worldwide safety and EMC standards. ORDERING GUIDE Model Number Natural Convection Cooling Main Output (V1) MVAD065-05 55W 5V MVAD065-12 12V 60W MVAD065-18 18V FEATURES MVAD065-24 24V 65W MVAD065-48 48V ITE (2nd Ed.) and Medical (3rd ed.) MOPP safety approved INPUT CHARACTERISTICS 55-65W compact high density Parameter Conditions Min. Typ. Max. Units 2 x 4 standard footprint Single phase 90 120/230 264 Vac Input Voltage Operating Range DC 120 300 Vdc High efficiency up to 90% Input Frequency 47 50/60 63 Hz Remote Sense Turn-on Input Voltage Input rising at full load 70 85 Vac Turn-off Input Voltage Input falling at full load 70 85 Universal AC input Input Current 90Vac input, full load 1.4 A Low profile - 1U package 5V 75 Inrush Current At 264Vac, at 25C cold start Apk Other 60 Convection-cooled operation up to 65W OUTPUT CHARACTERISTICS Complies with 5000m altitude Main Output Line, Load, Cross Typical Efficiency RoHS compliant Model Number Load Current Load Capacitance Voltage (V1) Regulation 230Vac full load Input power < 74W MVAD065-05 5V 0 to 11A 0 to 2200F 2% 84% MVAD065-12 12V 0 to 5.0A 0 to 1000F 2% 88% UL Class I and II approved MVAD065-18 18V 0 to 3.34A 0 to 680F 2% 86% Less than 0.3W no load input power MVAD065-24 24V 0 to 2.71A 0 to 560F 2% 89% MVAD065-48 48V 0 to 1.36A 0 to 330F 2% 90% Complies with ErP/Energy Star requirement excluding 5V output MAIN OUTPUT CHARACTERISTICS Max. Parameter Conditions Min. Units 5V Other Transient Response 50% load step, 1A/sec slew rate 5 % Settling Time to 1% of Nominal 500 200 sec Turn On Delay After application of input power 1 sec Output Voltage Rise Monotonic, 0 to 100% load 50 msec Setpoint Accuracy 120Vac, 40W, 25C 1 0.5 % Output Holdup 115Vac, 100% load 10 msec Temperature Coefficient 0.02 %/C 1 Ripple Voltage & Noise 2 1 % Compensates for up to 400mV of lead drop with remote sense 3 Remote Sense 400 mV connected. Protected against short circuit and reverse connection. 1. Ripple and noise are measured with 0.1 uF of ceramic capacitance and 47 uF of electrolytic capacitance on each of the power supply outputs. The output noise requirements apply over a 0 Hz to 20 MHz bandwidth. A short coaxial cable with 50ohm scope termination is used. Available now at 2. Unless otherwise specified all readings are taken a t 120Vac input and 25C ambient temperature. MVAD065 Series 65W 2 x 4 AC-DC Power Supply Converter ENVIRONMENTAL CHARACTERISTICS Parameter Conditions Min. Typ. Max. Units Storage Temperature Range -40 85 See thermal derating curves -10 70 C Operating Temperature Range Start up -20 Operating Humidity Non-condensing 10 95 % For Class I ITE Equipment deployment -200 5000 Operating Altitude m Other -200 2000 MTBF Telcordia SR-332 M1C3 25C 1M Hours Operating, IEC60068-2-27, half-sine 5G, 6ms, Complies 3 times per face, 6 faces Shock Non-operating, IEC60068-2-27, half-sine, Complies 30G, 18ms, 3 times per face, 6 faces Operating, IEC60068-2-6, 1.0G, 10-150Hz, 10 Complies minutes per axis, on all 3 axes Vibration Non-operating, IEC60068-2-6, 2.0G, Complies 10-150Hz, 10 minutes per axis, on all 3 axes IEC60950-1:2005 (2nd Edition) Am1:2009 UL60950-1 2nd Edition,2011-12-19, CSA C22.2 No. 60950-1-07, 2nd Edition,2011-12 EN60950-1:2006 + A11:2009 + A1:2010 + A12:2011 Safety IEC60601-1:2005 + CORR.1(2006) + CORR.2(2007) ANSI/AAMI ES60601-1 (2005+C1:09 + A2:10), CSA-C22.2 No. 60601-1(2008), MOPP CE Marking per LVD Warranty 2 years Outside Dimensions 2.0 x 4.0 x 1.3 (50.8mm x 101.6mm x 33.02mm) MVAD065-05 / MVAD065-18 0.285lbs (130g) typical Weight Other 0.27lbs (123g) typical PROTECTION CHARACTERISTICS Parameter Conditions Min. Typ. Max. Units MVAD065-05 Latching (50% load) 110 190 Overvoltage Protection %V1 Other Latching (60% load) 110 160 Overcurrent Protection Hiccup mode 110 160 %A ISOLATION CHARACTERISTICS Parameter Conditions Min. Typ. Max. Units Primary to Earth Ground (1xMOPP) 1500 Vac 4 Isolation Primary to Secondary (2xMOPP) 4000 Secondary to Earth Ground 500 Vdc 240Vac, 60Hz, 25C 300 Leakage Current (under normal conditions) 264Vac, 60Hz, 25C 350 A Touch Current 264Vac, 60Hz, 25C 100 EMISSIONS AND IMMUNITY Characteristic Standard Compliance Input Current Harmonics IEC/EN 61000-3-2 Class A Voltage Fluctuation and Flicker IEC/EN 61000-3-3 Complies EN 55022 Class B, Class A (at Class II equipment) Conducted Emissions FCC Part 15 Class B, Class A (at Class II equipment) ESD Immunity IEC/EN 61000-4-2 Level 4, Criterion A Radiated Field Immunity IEC/EN 61000-4-3 Level 2, Criterion A Electrical Fast Transient Immunity IEC/EN 61000-4-4 Level 3, Criterion A Surge Immunity IEC/EN 61000-4-5 Level 4, Criterion A RF Conducted Immunity IEC/EN 61000-4-6 Level 2, Criterion A Magnetic Field Immunity IEC/EN 61000-4-8 Level 2, Criterion A Voltage dips, interruptions IEC/EN 61000-4-11 Level 3, Criterion B 4. At class I equipment. power.murata.com MVAD065.B01 Page 2 of 7