SF2314E Low-loss 866.5 MHz SAW Filter Designed for 50 ohm Source/Load Complies with Directive 2002/95/EC (RoHS) Pb 866.5 MHz Absolute Maximum Ratings SAW Filter Rating Value Units Input Power Level +18 dBm DC Voltage on any Non-ground Terminal 3 V Operable Temperature Range -45 to +125 C Specification Temperature Range -40 to +85 C Storage Temperature Range in Tape and Reel -40 to +85 C C Maximum Soldering Profile, 5 cycles/10 seconds maximum 265 SM3030-6 Electrical Characteristics Characteristic Sym Notes Min Typ Max Units Center Frequency f 866.5 MHz C Insertion Loss, 863 to 870 MHz IL 2.3 3.0 dB dB Amplitude Ripple, 863 to 870 MHz 0.3 1.3 P-P VSWR, 863 to 870 MHz 1.2:1 2.0:1 Attenuation, Referenced to 0 dB: 10 to 830 MHz 45 49 830 to 850 MHz 22 35 885 to 905 MHz 27 35 dB 905 to 950 MHz 45 49 950 to 1500 MHz 40 47 1500 to 3000 MHz 25 28 Z Source Impedance 50 S Z Load Impedance 50 L Case Style SM3030-6 3.0 x 3.0 mm Nominal Footprint Lid Symbolization (Y=year, WW=week, S=shift) dot=pin 1 indicator A71, YWWS Standard Reel Quantity Reel Size 7 inch 500 Pieces/Reel Reel Size 13 inch 3000 Pieces/Reel Electrical Connections Connection Terminals Input 2 Output 5 Case Ground All others CAUTION: Electrostatic Sensitive Device. Observe precautions for handling. Notes: 1. Unless noted otherwise, all specifications apply over the operating temperature range with filter soldered to the specified demonstration board with impedance matching to 50 and measured with 50 network analyzer. 2. Unless noted otherwise, all frequency specifications are referenced to the nominal center frequency, fc. 3. Rejection is measured as attenuation below the minimum IL point in the passband. Rejection in final user application is dependent on PCB layout and external impedance matching design. See Application Note No. 42 for details. 4.LRI or after the part number indicateslow rate initial productio andEN or indicatesengineering prototypes 5. The design, manufacturing process, and specifications of this filter are subject to change. 6. Either Port 1 or Port 2 may be used for either input or output in the design. However, impedances and impedance matching may vary between Port 1 and Port 2, so that the filter must always be installed in one direction per the circuit design. 7. US and international patents may apply. 8. Murata, stylized Murata logo, and Murata N.A., Inc. are registered trademarks of Murata Manufacturing Co., Ltd. Copyright Murata Manufacturing Co., Ltd. All rights reserved. February 2015 SF2314E (R) 8/10/17 Page 1 of 5 www.murata.comFilter Response Plots Copyright Murata Manufacturing Co., Ltd. All rights reserved. February 2015 www.murata.com SF2314E (R) 8/10/17 Page 2 of 5