INFC Panel Meters/Controllers Process Strain Thermocouple RTD NEWPORT INFINITY series feature the THERMOCOUPLE METER/ PROCESS and STRAIN biggest brightest display of any 1/8 DIN The INFCP and INFCS meters accept a CONTROLLER panel meter. The user can select the wide range of DC voltage and current The NEWPORT INFCT accepts type J, K, display color: RED, AMBER, or GREEN. inputs to cover any typical process T and DIN J thermocouples. Standard application, 0-100 mV, 50 mV, 0-10 V, features include resolution of 0.1 or 1.0, PANEL METERS/CONTROLLERS 5 V, 0-20 mA, 4-20 mA. Sensor F or C indication. Factory default setup The unparalleled accuracy of the Excitation voltage 5, 10, 12 or 24 Vdc. is type K thermocouple input in F. NEWPORT INFINITY signal conditioning is available in an economical The INFINITY C features easy front RTD TEMPERATURE METER/ series of Panel Meter/Controllers. panel scaling to virtually any engineering CONTROLLER The INFINITY series of meter/ units, selectable excitation of four The INFCRaccepts 3-wire 100 ohm RTD controllers feature a four digital display voltages to work with most transducers platinum inputs (alpha = 0.00385) and plus optional dual 5 amp Form C relays and transmitters, front panel and remote has an accuracy of 0.5C. Relay models and a choice of isolated or non-isolated tare function for weighing applications, offer the choice of linear or proportional analog output.The scalable 0-10 Vdc, and a hardware lockout to prevent analog output. 0-20mA, or 4-20 mA analog output can be unauthorized changes in setup. used a retransmission of the display value or as aproportional control output as required. The microprocessor based Model No. Signal Input INFINITY series includes instruments INFCP ( * ) ( * ) Process (4-20 mA, 0-10 Vdc, 1-5 Vdc, 0-100 mVdc) for Process (DC voltage and current) INFCS ( * ) ( * ) Strain gauge / bridge input with excitation Strain Gage, Thermocouple, RTD, INFCT ( * ) ( * ) Thermocouple J, K, T, J DIN Dual/Differential Thermocouple, INFCR ( * ) ( * ) RTD 100 ohm pt 2-, 3-, 4- wire Dual/Differential RTD, pH, ORP. Meter Power COMMONSPECIFICATIONS 0 115 Vac power Display: 1 230 Vac power 4-Digit, 9 segment, 21 mm (0.83 ) 4 10-32 Vdc power Accuracy: 25C: 0.03% of readings, 6 26-56 Vdc power 1 count (INFCP and INFCS) Control Output 0.05C (INFCT and INFCR) 0 No control output Internal Resolution: 15 bits 1 Two 5 A form C relays Polarity: Automatic Power: 115 Vac, 230 Vac, Analog Output 10-32 Vdc or 26-56 Vdc 0B No analog output Dimensions: 48 H x 96 W x 152 D mm 1B 4 to 20 mA or 0 to 10 Vdc (non-isolated) 2B 4 to 20 mA or 0 to 10 Vdc (isolated) (1.89 x 3.78 x 6.0 ) Panel Cutout: Factory Scale Option 45 H x 92 W mm (1.772 x 3.622 ) , FS Factory Scaling Operating Temperature: 0 to 50C (32 to 123F) Must be ordered with relay option Ordering Example: INFCP-000B,FS: Process Meter factory scaled for 4-20 mA = 9999 84X-ON Electronics Largest Supplier of Electrical and Electronic Components Click to view similar products for newport manufacturer: Other Similar products are found below : BDS1 BDT1 WTK-14-36/N 5TC-TT-J-24-72 TXDIN70 OTP-U-F 5SC-TT-K-30-36 WTK-8-24/N OTP-U-M TPJ-U-F 5TC-TT-J-24-50/N 5SC-TT-T-30-72 SMTC-AL-P SMPW-CC-T-M MPJ-K-F-ROHS