M/58300 Flat Suction Cups 6 to 150 mm l Suitable for use on flat surfaces l Ideal for applications where a minimum of movement is required to maintain suction when supporting pliable materials l Wide variety of cup sizes available Technical Data Ordering Information Medium: To order a 30 mm flat suction cup in nitrile rub- Vacuum ber quote: M/58307/01 Cup Diameters: To order a 50 mm flat suction cup in silicone 6, 8, 10, 15, 20, 25, 30, 40, 50, 80, 120, 150 mm quote: M/58309/02 Operating Temperature: -10C* to +70C for Nitrile rubber cups -30C* to +200C for Silicone cups * Consult our Technical Service for use below +2C Accessories See page Other Features: Suction cup accessories N/UK 3.5.051.01 Material Nitrile Silicone Wear resistance Good Fair Oil resistance Excellent Fair Weather resistance Good Excellent Ozone resistance Fair Excellent Materials: M/58300/01 Nitrile rubber cups, aluminium connection fit- tings. M/58300/02 Silicone cups, aluminium connection fittings. Our policy is one of continued research and development. We therefore reserve the right 5/96 N/UK 3.5.011.01 to amend, without notice, the specifications given in this document.M/58300 Lifting Force Fy Fx Fx = Fy R Model 58301 58302 58303 58304 58305 58306 58307 58308 58309 58310 58311 58312 6 8 10 15 20 25 30 40 50 80 120 150 -0,2 bar 0,5 1 1,5 2,7 5 9 11 19 30 86 180 280 Fy (N)-0,6 bar 1,5 2,5 4 8 15,5 26,5 34 57,5 91 260 540 842 -0,9 bar 2,3 3,5 6 12 23 40 51 86 135 390 810 1250 R (mm) 5 7 9 12 13 17,5 26 37 41 100 365 380 S (mm) 1,5 1,5 2 4 2 2,5 2,5 3,5 4 6 6 9 3 V (cm ) 0,017 0,041 0,065 0,330 0,500 0,750 1,3 3 4,2 21 82 177 R = Minimum radius of work surface, S = Maximum movement, V = Volume inside Note: Theoretical values are given in this table. Always allow a safety factor of > 2. Weights for Suction Cups Model 58301 58302 58303 58304 58305 58306 58307 58308 58309 58310 58311 58312 6 8 10 15 20 25 30 40 50 80 120 150 Weight (kg) 0,001 0,001 0,001 0,001 0,008 0,010 0,012 0,011 0,016 0,058 0,359 0,590 Basic Dimensions I I I G G G SW SW G SW D D D D 6 to 30 40 and 50 80 120 and 150 Model 58301 58302 58303 58304 58305 58306 58307 58308 58309 58310 58311 58312 D 6 8 1015202530405080120 150 A 4,5 4,5 4,5 4,5 8 8 8 6 6 13 9,5 9,5 C - ------9 11 3,5 -- G M 5 M 5 M 5 M 5 G 1/8 A G 1/8 A G 1/8 A G 1/8 G 1/8 G 1/8 G 1/2 G 1/2 H 15 16 20 21 19,5 20 20,5 23 26 21,5 34,5 41,5 I - - - - - - - 24 26 53 65 65 SW (A/F) 8 8 8 8 14 14 14 14 14 19 - - Warning These products are intended for use in industrial compressed air sys- The system designer is warned to consider the failure modes of tems only. Do not use these products where pressures and tempera- all component parts used in fluid power systems and to provide ade- tures can exceed those listed under Technical Data. quate safeguards to prevent personal injury or damage to equipment in the event of such failure. Before using these products with fluids other than those specified, System designers must provide a warning to end users in the for non-industrial applications, life-support systems, or other applica- system instructional manual if protection against a failure mode tions not within published specifications, consult NORGREN. cannot be adequately provided. System designers and end users are cautioned to review specific Through misuse, age, or malfunction, components used in warnings found in instruction sheets packed and shipped with fluid power systems can fail in various modes. these products. Our policy is one of continued research and development. We therefore reserve the right N/UK 3.5.011.02 5/96 to amend, without notice, the specifications given in this document. A H C A H C A H S A H