Small Enclosed Switches VE CSM VE DS E 2 2 Small, Lightweight Enclosed Switches V-series Switches were placed in diecast cases to provide superior dust resistance and mechanical strength. Cam arms and cam roller arms can be set to any position within 360 Be sure to read Safety Precautions on page 4 and Precautions for All Limit Switches. Model Number Legend Model Number Structure (Some combinations may not be available. Contact your OMRON sales representative for details.) VE-10 - - 1234 1. Number of Built-in 3. Operation Direction 4. Bushing Type Blank: Rubber bushing for single-core vinyl cables Switches (for Arm Actuators Only) C: Rubber bushing for vinyl cabtire cable 1: 1 Blank: Plunger Note: For details, refer to Safety Precautions on page 4. 11: Counterclockwise operation 2. Actuator Type (one-side operation) N: Sealed plunger 12: Clockwise operation CA: Cam arm (one-side operation) CA2: Cam roller arm 13: Operation in both directions (two-side operation) Ordering Information One built-in switch Actuator type Operating direction Model Sealed plunger --- 1VE-10N Counterclockwise 1VE-10CA-11 operation Cam arm Clockwise 1VE-10CA-12 operation Two-side operation 1VE-10CA-13 Counterclockwise 1VE-10CA2-11 operation Cam roller arm Clockwise 1VE-10CA2-12 operation Two-side operation 1VE-10CA2-13 1VE Ratings and Specifications Ratings Non-inductive load (A) Inductive load (A) NC 24 A max. Inrush Rated current Resistive load Lamp load Inductive load Motor load NO 24 A max. voltage (V) NC NO NC NO NC NO NC NO Note: 1. The above values are continuous 125 AC 10 2 10 3 currents. 250 10 1.5 10 2 2. Inductive loads have a power factor of 0.4 or higher (AC) or a 8 DC 10 2 6 6 14 10 3 6 6 time constant of 7 ms or lower 30 6 3 4 4 (DC). 125 0.6 0.1 0.6 0.1 3. Lamp loads have an inrush 250 0.3 0.05 0.3 0.05 current of 10 times the steady- state current. 4. Motor loads have an inrush current of 6 times the steady-state current. Characteristics Engineering Data Switch with Cam Roller Arm Electrical Degree of protection IP60 Durability Graph Mechanical 1,500,000 operations min. Durability* Operating frequency: 60 operations/min Electrical 300,000 operations min. (10 A at 250 VAC, resistive load) 200 Operating angle: 60 degrees cos = 1 Sealed plunger: 0.1 mm/s to 0.5 m/s Operating speed Cam arm: 0.5 mm/s to 0.5 m/s 100 250 VAC Cam roller arm: 0.5 mm/s to 0.5 m/s 70 Allowable Mechanical 120 operations/min. 50 operating Electrical 60 operations/min. frequency 30 Rated frequency 50/60 Hz 20 Insulation resistance 100 M min. (at 500 VDC) 10 Contact resistance 15 m max. (initial value) Between terminals of 1,000 VAC at 50/60 Hz for 1 minute the same polarity Dielectric Between each terminal strength 0 24 6 8 10 and non-current- 1,500 VAC, 50/60 Hz for 1 minute Switching current (A) carrying parts Vibration resistance Malfunction: 10 to 55 Hz, 1.5-mm double amplitude 2 2 Shock resistance Destruction: 1,000 m/s max., Malfunction: 300 m/s max. Ambient operating temperature 10C to 80C (with no icing) Ambient operating humidity 35% to 95% Weight Approx. 120 to 170 g Note: The above values are initial values. * The values are calculated at an operating temperature of 5C to 35C and an operating humidity of 40% to 70%. Contact your OMRON sales representative for more detailed information on other operating environments. Nomenclature Structure Contact Form Roller Built-in Switch (V) COM NC NO Roller arm Case Cover Conduit cap 2 4 Operations (x 10 )