Temperature Controllers E5CSV Simple to Set and Operate 1/16 DIN Size Controllers Easy setting using internal DIP and rotary switches ON/OFF or PID control (with on-demand auto-tuning) selectable Clearly visible digital display with character height of 13.5 mm Deviation indicator makes monitoring more effective Multiple temperature sensor input (thermocouple/platinum resistance thermometer) models stocked thermocouple input only and platinum RTD input only models available Models with two alarms are ideal for temperature alarm C or F field selectable applications Black or white cases available to match panel aesthetics Setting change protection prohibits tampering RoHS compliant Sampling rate (500 ms) and selectable control period (2 and 20 s) improves response Water-resistant front panel rated NEMA 4X/IP66 8-mode alarm output and sensor error detection Compact: measures 48 H x 48 W x 78 D mm Input shift function adjusts display to reflect known sensor Accuracy 0.5% of value offsets Model Number Structure Model Number Legend Models with Terminal Blocks 1 2 3 4 5 6 1. Output type 4. Power supply voltage R: Relay Blank: 100 to 240 VAC Q: Voltage for driving SSR D: 24 VAC/VDC 2. Number of alarms 5. Case color / Display scale Blank:No alarm Blank: Black 1: 1 alarm W: Light gray 2: 2 alarms F: Scale marked in F (Black case only) 3. Input type 6. Power supply voltage T: Thermocouple/platinum resistance thermometer AC100-240: 100 to 240 VAC (multi-input) AC/DC24: 24 VAC/VDC KJ: Thermocouple P: Platinum resistance thermometer Note: A functional explanation is provided here for illustration, but models are not necessarily available for all possible combinations. Please refer to Ordering Information when ordering. Examples Voltage control output, without alarm, multi-input, light gray case: 115 VAC: E5CSV-QT-W AC100-240 Relay control output, one alarm output, multi-input, black case: 24 VDC: E5CSV-R1TD AC/DC24 Temperature Controllers E5CSVOrdering Information List of Models Size Power Number Control output TC/Pt multi-input TC input Pt input TC/Pt multi-input supply of alarm Case color: Black Case color: Case color: Case color: Black voltage points Scale marked in C Light gray Light gray Scale marked in F Scale marked in C Scale marked in C 1/16 DIN 100 to 240 0 Relay E5CSV-RT AC100-240 E5CSV-RT-F AC100-240 48 48 78 mm VAC Voltage (for driving SSR) E5CSV-QT AC100-240 E5CSV-QT-F AC100-240 (W H D) 1 Relay E5CSV-R1T AC100-240 E5CSV-R1KJ-W E5CSV-R1P-W E5CSV-R1T-F AC100-240 Voltage (for driving SSR) E5CSV-Q1T AC100-240 E5CSV-Q1KJ-W E5CSV-Q1P-W E5CSV-Q1T-F AC100-240 2 Relay E5CSV-R2T AC100-240 E5CSV-R2T-F AC100-240 (See note) Voltage (for driving SSR) E5CSV-Q2T AC100-240 E5CSV-Q2T-F AC100-240 24 VAC/ 0 Relay E5CSV-RTD AC/DC24 VDC Voltage (for driving SSR) E5CSV-QTD AC/DC24 1 Relay E5CSV-R1TD AC/DC24 E5CSV-R1TD-F AC/DC24 Voltage (for driving SSR) E5CSV-Q1TD AC/DC24 E5CSV-Q1TD-F AC/DC24 2 Relay E5CSV-R2TD AC/DC24 (See note) Voltage (for driving SSR) E5CSV-Q2TD AC/DC24 Note: Models with two alarm outputs always use the upper limit alarm mode for the alarm 2 output. Accessories (Order Separately) Protective Cover Type Model Hard Protective Cover Y92A-48B Terminal Cover Model E53-COV10 Specifications Ratings Supply voltage 100 to 240 VAC, 50/60 Hz 24 VAC/VDC, 50/60 Hz Operating voltage range 85% to 110% of rated supply voltage Power consumption 5 VA 3 VA/2 W Sensor input Thermocouple input type: K, J, L Platinum resistance thermometer input type: Pt100, JPt100 Multi-input (thermocouple/platinum resistance thermometer) type: K, J, L, T, U, N, R, Pt100, JPt100 Control Relay output SPST-NO, 250 VAC, 3A (resistive load) output Voltage output (for driving the SSR) 12 VDC, 21 mA (with short-circuit protection circuit)3 Control method ON/OFF or 2-PID (with auto-tuning) Alarm output SPST-NO, 250 VAC, 1A (resistive load) Setting method Digital setting using front panel keys Indication method 3.5 digit, 7-segment digital display (character height: 13.5 mm) and deviation indicators Other functions Setting change prohibit (key protection) Input shift Temperature unit change ( C/ F) Direct/reverse operation Temperature range, Sensor switching (K/J/L, Pt100/JPt100) Switching is performed between a thermocouple and platinum resistance thermometer for multi-input models. Control period switching 8-mode alarm output Sensor error detection Ambient temperature 10 to 55 C (with no condensation or icing) Ambient humidity 25% to 85% Storage temperature 25 to 65 C (with no condensation or icing) 2 Temperature Controllers E5CSV