Solid State Relays G3 -VD G3H/G3HD CSM G3H G3HD DS E 6 3 New Models with International Standards Added to G3H Series (-VD in model number). Same Profile as LY1 and LY2 Bi-power Relays Certified by UL, CSA, and VDE (models numbers with a suffix of -VD). Socket type, same size as LY Power Relays. Operation indicator provided to confirm input (models numbers with N before the suffix). Refer to Safety Precautions for All Solid State Relays. Note: The socket is optional. For the most recent information on models that have been certified for safety standards, refer to your OMRON website. Model Number Structure Model Number Legend G3H- - 234 56 7 8 1 1. Basic Model Name 6. Zero Cross Function G3H: Solid State Relay Blank: Equipped with zero cross function 2. Rated Load Power Supply Voltage L: Not equipped with zero cross function 2: 200 VAC 7. Operation Indicator Blank: Not equipped with operation indicator 3, 4. Rated Load Current N: Equipped with operation indicator 03: 3 A 8. Certification 5. Terminal Type VD: Certified by UL, CSA, and VDE standards S: Plug-in terminals G3HD- - 7 234 56 1 1. Basic Model Name 5. Terminal Type G3H: Solid State Relay S: Plug-in terminals 2. Load Power Supply Type 6. Operation Indicator D: DC Blank: Not equipped with operation indicator 3. Rated Load Power Supply Voltage N: Equipped with operation indicator X: 50 VDC 7. Certification 4. Rated Load Current VD: Certified by UL, CSA, VDE 03: 3 A 1G3H/G3HD Ordering Information List of Models Isolation Zero cross Indicator Rated output load Rated input voltage Model function Photocoupler Yes Yes 3 A at 100 to 240 VAC *1 5 to 24 VDC G3H-203SN-VD Phototriac coupler No 5 VDC G3H-203SLN-VD 12 VDC 24 VDC Photocoupler --- 3 A at 4 to 48 VDC *2 5 to 24 VDC G3HD-X03SN-VD Photocoupler Yes No 3 A at 100 to 240 VAC *1 4 to 24 VDC G3H-203S-VD Phototriac coupler No 5 VDC G3H-203SL-VD 12 VDC 24 VDC Photocoupler --- 3 A at 4 to 48 VDC *2 4 to 24 VDC G3HD-X03S-VD *3 Photovoltaic coupler --- Yes 2.5 A at 24 to 240 VDC 12 to 24 VDC G3HD-202SN-VD *4 *1 Product is labelled 240 VAC. *2 Product is labelled 48 VDC. *3 Product is labelled 240 VDC. *4 Application is possible for a half-wave rectification load between 19.2 and 264 VAC. Accessories (Order Separately) Connecting Sockets/Hold-Down Clips Front-mounting Sockets Back-mounting Sockets Socket PTF08A(-E) PT08 PT08-0 PT08QN Hold-down Clip PYC-A1 PYC-P PYC-P PYC-P PYC-S PYC-S Specifications Ratings (at an Ambient Temperature of 25C) Input Model Rated voltage Operating voltage Impedance Voltage level Must operate voltage Must release voltage G3H-203SN-VD 5 to 24 VDC 4 to 28 VDC 15 mA max. (See note 2.) 4 VDC max. 1 VDC min. G3H-203SLN-VD 5 VDC 4 to 6 VDC 390 20% 4 VDC max. 1 VDC min. 12 VDC 9.6 to 14.4 VDC 900 20% 9.6 VDC max. 24 VDC 19.2 to 28.8 VDC 2 k20% 19.2 VDC max. +20% G3HD-X03SN-VD 5 to 24 VDC 4 to 28 VDC 4 VDC max. 1 VDC min. 1.5 k /10% (See note 1.) G3H-203S-VD 4 to 24 VDC 3 to 28 VDC 15 mA max. (See note 2.) 3 VDC max. 1 VDC min. G3H-203SL-VD 5 VDC 4 to 6 VDC 390 20% 4 VDC max. 1 VDC min. 12 VDC 9.6 to 14.4 VDC 900 20% 9.6 VDC max. 24 VDC 19.2 to 28.8 VDC 2 k20% 19.2 VDC max. +20% G3HD-X03S-VD 4 to 24 VDC 3 to 28 VDC 3 VDC max. 1 VDC min. 1.5 k /10% (See note 1.) G3HD-202SN-VD 12 to 24 VDC 9.6 to 28.8 VDC 25 mA max. (at 24 VDC) 9.6 VDC max. 1 VDC min. (See note 2.) Note: 1. The input impedance is given for the maximum operating voltage. For details, refer to the Technical Guide for Solid State Relays. 2. With constant current input system. 2