Soft-start Solid State Contactors G3J-S CSM G3J-S DS E 3 2 Soft-start Function Starts Motors Smoothly and Economically The soft-start function allows a smooth startup of motors by holding down the starting current, and functions like an inverter. Comply with UL, CSA, IEC, and JEM requirements. Mount with screws or to DIN tracks. Compact monoblock construction (W: 80 H: 100 D: 100 mm) with a heat sink. Snubber circuit and varistor are built-in. Operation indicator. Refer to Safety Precautions for All Solid State Relays. For the most recent information on models that have been certified for safety standards, refer to your OMRON website. Model Number Structure Model Number Legend G3J- 1234567 1. Basic Model Name 5. Rated Load Current G3J: Solid State Contactor 11: 11.1 A (200-V models) 2. Load Power Supply 05: 4.8 A (200-V models), 5.5 A (400-V models) Blank: AC output 03: 2.4 A (400-V) models 3. Functions 6. Terminal Type S: Soft-start function B: Screw terminals 4. Rated Load Power Supply Voltage 7. Zero Cross Function 2: 200 VAC L: Not equipped with zero cross function 4: 400 VAC Appearance Output terminals (power supply) Operation indicator Input terminals Initial torque setting adjuster (default setting: 200%) Ramp-up time setting adjuster (default setting: 1 s) Output terminals (load) 1G3J-S Ordering Information List of Models Number of Insulation method Rated supply Input method Applicable motor Model elements voltage 3 Phototriac 12 to 24 VDC No-voltage input 2.2 kW (5.5 A) 380 to 400 VAC G3J-S405BL (open and short- 0.75 kW (2.4 A) G3J-S403BL circuit input) 2.2 kW (11.1 A) 200 to 220 VAC G3J-S211BL 0.75 kW (4.8 A) G3J-S205BL Note: When ordering, specify the rated supply voltage. Specifications Ratings (at an Ambient Temperature of 25C) Power Supply Rated supply voltage 12 to 24 VDC Operating voltage range 10.2 to 26.4 VDC Current consumption 100 mA max. (at 12 to 24 VDC) Operation Circuit Input current 10 mA max. (at 12 to 24 VDC) Input method Short-circuiting or opening terminals 1 and COM or 2 (+) and 1 No-voltage input (short-circuiting and SSR input turned ON: A maximum residual voltage of 2 V between short-circuited terminals opening inputs) (See note.) SSR input turned OFF: A maximum leakage current of 0.15 mA Relay input: For minute signals Note: Refer to Safety Precautions for the G3J-T, G3J-S, and G3J. Main Circuit Item G3J-S405BL G3J-S403BL G3J-S211BL G3J-S205BL Rated load voltage 200 to 400 VAC (50/60 Hz) 200 to 240 VAC (50/60 Hz) Load voltage range 180 to 440 VAC (50/60 Hz) 180 to 264 VAC (50/60 Hz) Rated carry current 5.5 A (Ta = 40C) 2.4 A (Ta = 40C) 11.1 A (Ta = 40C) 4.8 A (Ta = 40C) Min. load current 0.5 A Peak-value current resistivity 220 A, 60 Hz, 1 cycle 96 A, 60 Hz, 1 cycle 350 A, 60 Hz, 1 cycle 150 A, 60 Hz, 1 cycle Overload resistance Refer to Information Common to the G3J, G3J-T, and G3J-S. Closed current AC3 55 A 24 A 111 A 48 A (effective value) AC4 66 A 28.8 A 133.2 A 57.6 A Breaking current AC3 44 A 19.2 A 88.8 A 38.4 A (effective value) AC4 55 A 24 A 111 A 48 A Applicable load 3-phase inductive 380 to 400 VAC, 2.2 kW, 380 to 400 VAC, 200 to 220 VAC, 2.2 kW, 200 to 220 VAC, motor (AC3 AC4 5.5 A 0.75 kW, 2.4 A 11.1 A 0.75 kW, 4.8 A AC53-a) Motors passing the AC3-class, AC4-class, and AC53-a-class switching frequency test (Ta = 40C) under conditions specified by OMRON. Refer to Information Common to the G3J, G3J-T, and G3J-S. Resistive load 200 to 400 VAC, 5.5 A 200 to 400 VAC, 2.4 A 200 to 240 VAC, 11.1 A 200 to 240 VAC, 4.8 A (AC1) (See note.) Note: No single-phase load can be connected. 2